F-2

HOW TO USE TROUBLESHOOTING GUIDE

Service and repair should be performed by only Lincoln Electric Factory Trained Personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician and machine
operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please
observe all safety notes and precautions detailed throughout this manual.
This Troubleshooting Guide is provided to help
you locate and repair possible machine
malfunctions. Simply follow the three-step
cedure listed below.
Step 1. LOCATE PROBLEM (SYMPTOM). Look
under
the
column
(SYMPTOMS)". This column describes possible
symptoms that the machine may exhibit. Find
the listing that best describes the symptom that
the machine is exhibiting.
grouped into categories of typical problems.
Step 2. PERFORM EXTERNAL TESTS. The
second column, labeled "POSSIBLE AREAS OF
MISADJUSTMENT(S)", lists the obvious external
possibilities that may contribute to the machine
symptom.
Perform these tests/checks in the
order listed. In general, these tests can be con-
ducted without removing the case wrap-around
cover.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-888-935-3877.
TROUBLESHOOTING & REPAIR
CAUTION
pro-
labeled
"PROBLEM
Symptoms are
CAUTION
V300-PRO
Step 3. PERFORM COMPONENT TESTS. The
last column, labeled "Recommended Course of
Action" lists the most likely components that may
have failed in your machine. It also specifies the
appropriate test procedure to verify that the
subject component is either good or bad. If there
are a number of possible components, check the
components in the order listed to eliminate one
possibility at a time until you locate the cause of
your problem.
All of the referenced test procedures referred to in
the Troubleshooting Guide are described in detail
at the end of this chapter.
Troubleshooting and Repair Table of Contents to
locate each specific Test Procedure. All of the
referred to test points, components, terminal
strips, etc., can be found on the referenced
electrical wiring diagrams and schematics. Refer
to the Electrical Diagrams Section Table of
Contents to locate the appropriate diagram.