Retest After Repair - Lincoln Electric COMMANDER 400 SVM133-B Service Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

F-117
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine's electrical characteristics.
• If you repair or replace any electrical components.
Mode
Low Idle
High Idle
Range Switch
Maximum
Range Switch
Maximum
230 Volt Receptacle
Open Circuit
Load Volts
Voltage
230 - 250
TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR

OR
ENGINE OUTPUT
No Load RPM
1325 - 1400
1890 - 1915
WELDER DC (STICK) OUTPUT
Fine Control
Open Circuit
Volts
Maximum
WELDER CV (WIRE) OUTPUT
Fine Control
Open Circuit
Volts
Maximum
AUXILIARY POWER OUTPUT
Load Amps
224
44.6
COMMANDER 400
Load Volts
70
40
Load Volts
48
40
115 Volt Receptacle
Open Circuit
Load Volts
Voltage
115 - 132
108 - 126
F-117
Load RPM
NA
1800
Load Amps
500
Load Amps
500
Load Amps
13 - 16