Lincoln Electric COMMANDER 400 SVM133-B Service Manual page 144

Lincoln electric welder user manual
Table of Contents

Advertisement

F-90
REMOVAL AND REPLACEMENT (continued)
SHUNT
REMOVE BOLT
AT POSITIVE
HEAT SINK
PLATE (LOWER)
STATOR WELD
WINDING LEADS
PROCEDURE
1. Turn the engine off.
2. Perform
the
Procedure (including front shroud removal).
3. Using the 1/2" wrench, remove the stator weld
winding leads from the SCR/diode rectifier
bridge assembly. See Figure F.37 and the
Wiring Diagram. Cut any necessary cable ties
and clear the leads.
4. Using the 1/2" wrench, remove lead #209
(small) and #209A (large) from the negative
(upper) heat sink plate. See Figure F.37 and
the Wiring Diagram.
5. Using the 1/2" wrench, remove the heavy
#204C lead from the positive heat sink plate
(lower).
See Figure F.37 and the Wiring
Diagram.
TROUBLESHOOTING & REPAIR
SCR/DIODE RECTIFIER BRIDGE
FIGURE F.37 – SCR/DIODE RECTIFIER BRIDGE DETAILS
Case
Cover
Removal
COMMANDER 400
6. Using the 1/2" wrench,
from the positive heat sink plate (lower). See
Figure F.37 and the Wiring Diagram.
NOTE: The "DD" diode pigtail lead and the three
small #204, #204A and #204B leads are also
incorporated in the bolted connection. They can
stay in place.
7. Using the 5/16" nut driver, remove the control
board cover.
8. Remove plug J6 and the toroid assembly from
the control board. Remove plug J6 and leads
from the control box. Cut any necessary cable
ties.
F-90
#209 (small)
#209A (large)
#204C
remove the shunt