Auger/Impeller; Auger/Impeller Repair; Shear Bolts - Ariens 939 SNO-THRO 939001 Service Manual

Ariens snow blower user manual
Table of Contents

Advertisement

3
2
1
6
PS0361-1
WARNING: Stop engine, remove key, wait for
moving parts to stop and remove wire from
spark plug before leaving operator's position
and attempting to maintain or inspect auger.

9.1 AUGER/IMPELLER REPAIR

1. Place machine on a flat, level surface.
NOTE: Placing blocking under the runners on the
blower housing may make auger removal easier.
2. Remove bolt holding auger drive pulley to shaft
and remove pulley.
3. Remove three tapping screws holding shaft
bushing to blower housing and remove flange on
each side.
4. Grasp auger assembly and pull gear case and
auger/impeller assembly free of housing.
5. Remove shear bolts and remove auger from shaft.
6. Check all parts for wear or replacement.
7. Assemble, using reverse procedure.
SECTION 9 - AUGER/IMPELLER
4
5
6
8
7
Figure 24
10. Shear Bolt
8
9
10

9.2 SHEAR BOLTS

IMPORTANT: Use only Ariens shear bolts for
replacement. Use of any other type of shear bolt may
result in severe damage to unit.
Occasionally an object may enter auger/impeller
housing and jam auger, breaking shear bolts which
secures auger to shaft. This prevents damage to gear
drive by allowing auger to turn freely on shaft.
To replace shear bolt:
1. Slide auger outward and align hole in shaft with
hole in auger (Figure 24). The holes in shaft for roll
pins and shear bolts will line up.
2. Drive the new shear bolt through hole (if shear bolt
was broken this will drive remaining part from
shaft).
3. Secure with nut.
9 - 27
1. Auger Drive Pulley
2. Bolt
3. Locking Washer
4. Auger Drive Shaft
5. Blower Housing
6. Tapping Screw (3 each side)
7. Flange Bushing
8. Shaft Bushing
9. Auger
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sno-thro 939002Sno-thro 939300Sno-thro 939939001939002939000

Table of Contents