Summary of Contents for Dimplex KWP 300

  • Page 1 Installation and Operating Manual Heat Pump for Cooling of Domestic Water with Airduct Connection KWP 300 451902.67.39 FD8411...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Page Regulations / Safety Notices Description Refrigeration Cycle Water Circuit Safety and Control Devices Storage / Transport General Requirements Installation Installation Site Installation Mounting Connection of Water Piping Electrical Connection Commissioning Domestic Water Circuit Operation of the Heat Pump for Cooling of Domestic Water Maintenance / Service Water Circuit Air Circuit...
  • Page 3: Regulations / Safety Notices

    Regulations / Safety Notices This installation and operating manual must be read prior to starting up the unit ! ¾ ¾ ¾ ¾ # # # # The heat pump for cooling of domestic water (short: HPCDW) is designed exclusively for the cooling (in part also for the heating) of domestic or potable water within the specified operating temperature limits! The cooling (or heating) of liquids other than drinking water is not permissible.
  • Page 4: Description

    Description The HPCDW is a domestic water cooling unit ready for connection and essentially consists of a domestic water tank, the components of the refrigeration, air and water circuits as well as all control, regulating and monitoring devices required for automatic operation. In accordance with the heat pump's principle of operation, unwanted heat is extracted from the domestic water and then transferred to the discharged outlet air.
  • Page 5: Safety And Control Devices

    Safety and Control Devices The HPCDW is equipped with the following safety features: 2.3.1 High-pressure pressostat (HD) The high-pressure pressostat protects the heat pump from excessive operating pressures in the refrigeration cycle. In the case of a malfunction, the pressostat switches off the heat pump; the heat pump is restarted automatically as soon as the pressure in the refrigeration cycle has dropped to an acceptable level.
  • Page 6: Storage / Transport

    Storage and Transport General Requirements As a rule, the CWP is to be stored or transported in its shipping box in upright position and without water charge . For a transport over short distances, and provided due care is exercised, an inclination angle of up to 45° is permitted.
  • Page 7: Installation

    If the ceiling is lower and no airducts are used, an air ducting elbow (90° NW 160) must be used on the outlet air side (to ensure effective operation). When an air ducting elbow is used, care must be taken that it is slipped onto the flange collar of the discharge side in such a way that the discharge opening of the air ducting elbow is as far away from the intake opening of the unit as possible.
  • Page 8: Electrical Connection

    Electrical Connection The HPCDW is pre-wired, ready for connection, the power is supplied via the mains cable connected to a socket with earthing contact (GB: "Home Office socket") (~230 V, 50 or 60 Hz). This socket must be accessible also after the installation has been completed.
  • Page 9: Operation Of The Heat Pump For Cooling Of Domestic Water

    Operation of the HPCDW 6.2.1 Operating panel Temperature display The sensor of the thermostat (analog remote thermometer with trend display) senses the domestic water temperature at the middle part of the water tank. The display is located on the operating panel. Temperature display blue...
  • Page 10: Maintenance / Service

    6.2.2 Domestic water temperature controller (dial) The desired domestic water temperature level can be adjusted using the selector dial (an adjustment accurate to within one degree is not possible). 6.2.3 'Heat pump' switch If the 'heat pump' switch is placed in position “ “...
  • Page 11: Water Circuit

    Water Circuit The inspection of the water circuit is limited to any filters that may have been field-installed, and the performance of leak tests. Dirty water filters have to be cleaned and replaced, if necessary. Air Circuit The maintenance activities are limited to cleaning the fin-type heat exchanger (only) as required. Caution! Hazard of injury from sharp-edged fins.
  • Page 12: Malfunctions / Troubleshooting

    Malfunctions / Troubleshooting ( only for the user ) Caution! Arbeiten an der Kühl-Brauchwasser Wärmepumpe dürfen nur von sachkundigen Personen ausgeführt werden! Unfallverhütungsvorschriften sind zu beachten! Heat pump fails to run ! Please check whether Ö Ö Ö Ö the plug is plugged in Ö...
  • Page 13: Refrigeration Cycle With Legend

    11.1 Refrigeration Cycle with Legend PA-CO-H -CO-H -C I -L TI-CO-H -CO - L -C I - H freie Tauchhülse free immersion sleeve Compressor Safety temperature limiter 15 Non-return valve Pressostat HP Temp. controller immers. heater 16 Insulation Evaporator Temperature display Hot water tank Filter drier Immersion heater...
  • Page 14: Hydraulic Plumbing Diagram

    11.2 Hydraulic Plumbing Diagram water supply Wasserzulauf water connection acc. to DIN 1988 Wasseranschluß nach DIN 1988 domestic water outlet tap Brauchwasserentnahme filling Befüllung Shut-off valve Draining and filling valve Pressure reducing valve Diaphragm safety valve Test valve to be mounted above tank edge Check valve Drain Manometer connection...
  • Page 15: Circuit Diagram

    11.3 Circuit Diagram W ärmepumpe Heat pump Elektro - Heizstab el. Immersion heater Ventilator Compressor Verdichter T > +18..+26°C L/N/PE 230VAC 50Hz (+30 - +85°C ) +65°C T > Legende +99°C Betriebsthermostat W P B1 Operating thermostat, heat pump Regelthermostat-El.Heizung B3 Regulating thermostat, el.
  • Page 16: Technical Data

    11.4 Technical Data Heat pump for cooling of domestic water KWP 300 Type compact unit Nominal tank capacity ( litres) Tank material enamelled steel acc. to DIN 4753 Nominal tank pressure ( bar ) Dimensions ( cm ) 169 x 66 x 66...