Download Print this page
GE Tetra GEPS12-180U Installation Manual

GE Tetra GEPS12-180U Installation Manual

Ge tetra geps12-180u led systems power supply

Advertisement

Quick Links

GE
Lighting Solutions
Tetra
LED Systems Power Supply
®
(GEPS12-180U)

Power Supply Features

• Supports Tetra miniMAX, Tetra MAX, Tetra PowerMAX,
Tetra PowerStrip and Tetra miniStrip lighting systems
• Class 2 wiring per NEC Article 725 (SELV equivalent)
• Damp location rated
• IP66 rated: separate enclosure required
• Three 60 watt output banks

BEFORE YOU BEGIN

Read these instructions completely and carefully.
RISK OF ELECTRIC SHOCK:
• Disconnect power at fuse box or circuit breaker before servicing or
installing product.
• Properly ground Tetra
power supply.
®
RISK OF FIRE:
• Use only Tetra
supply wire to make connection from Tetra
®
supply to Tetra
LED strip.
®
• Use only approved wire for input/output connection.
Minimum size 18 AWG (0.82 mm
• Follow all local codes.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.

Power Supply Installation

Mount power supply and remove
1
junction box cover. Carefully remove
knockout for AC line input wires.
Install appropriate electrical fittings
in the knockout holes for wire
protection.
imagination at work
WARNING/AVERTISSEMENT
power
®
)
2
To Tetra LED System
Output wires
Connect the supply wire that is
2
attached to the Tetra LED System to
the red (+) and black (-) output wires
of the power supply as outlined in
the "Electrical Connections" section
of your LED system's Installation
Instructions.
NOTE: Three 60 watt output banks per
power supply. Do not interconnect
output terminations.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l'alimentation électrique à la boîte de fusibles ou au
disjoncteur avant l'entretien ou l'installation du produit.
• Assurez-vous de correctement mettre à terre l'alimentation
électrique Tetra
.
®
RISQUES D'INCENDIE
• N'utilisez que le fil d'approvisionnement Tetra
connexion entre l'alimentation Tetra
• N'utilisez que des fils approuvés pour les entrées/sorties de
connexion. Taille minimum 18 AWG (0.82 mm
• Respectez tous les codes locaux.
White
(neutral)
Connect the AC line to the black
3
(line) and white (neutral) input
wires of the power supply using
18-14 AWG (0.82-2.08 mm
wire connectors. Ground power
supply by connecting green wire
with yellow stripe to grounding
screw. Replace junction box cover.

Installation Guide

12
Volt
pour faire la
®
et la bande DEL Tetra
.
®
®
).
2
Green with
yellow stripe
(ground)
AC line
Black (line)
) twist-on
2

Advertisement

loading

Summary of Contents for GE Tetra GEPS12-180U

  • Page 1: Installation Guide

    Installation Guide Lighting Solutions Volt Tetra LED Systems Power Supply ® (GEPS12-180U) Power Supply Features • Supports Tetra miniMAX, Tetra MAX, Tetra PowerMAX, Tetra PowerStrip and Tetra miniStrip lighting systems • Class 2 wiring per NEC Article 725 (SELV equivalent) •...
  • Page 2: Power Supply Specifications

    1 - 8 8 8 - 6 9 - 4 3 - 5 3 3 GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the General Electric Company.