SPECIFICATIONS - Montage™ 3FS
Product Reference Information
Cat. No.
Model
H6839
Montage 3FS
Flue Size
Floor Protection
Requirements
Hopper Capacity
Burn time
Fuse, Control Board
Fuse, Igniter
Heat Input
(BTU's per hour)
Emissions
Convection (room air)
Blower
Combustion Blower
Auger Motor
Standard Features
Notes:
• Dimensions shown are approximations only
.25(+/- 1/4")
• Approved for Manufactured Home Installations.
Optional Kits Available - Decorative trim kits, log
set, window screen and 4" Quick Disconnect
kits.
• The burn grate is designed with advanced
UltraGrate™ technology.
u
Non-combustible floor protection is required
(see Floor Protection, Page 4). When installed
at clearances less than 6", the floor protector is
only required to extend to the wall.
v
Fuel delivery and burn times will vary depending
on size and type of fuel used. Estimated heat input
based on fuel value of 8400 BTU per lb.
w
Fuses are rated as fast blow.
6
Ship.
Ship.
Weight
Volume
85 lb.
.06 cu. ft.
3" (76 mm) Rear
Front and Sides: 6"(15 mm)
Back: Up to 6"(15 mm)
u
v
55 Lbs.
15 - 37 hours
v
5 Amp, 50 volt, 3AG
w
w
6 Amp, 15 volt
v
13,000 - 3,000 BTU/hr
< 4.5 gr/hr (varies w/size and
v
type of fuel) EPA Certified
150 CFM; 1.5 Amps,
175 rpm
95 CFM: 1.0 Amps,
3000 rpm
1.5 RPM; 0.5 Amps
Fastfire™ Self Igniter
Wall Thermostat
(wire included)
2-15/16"
51mm
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
24-11/16"
627mm
9-3/16"
233mm
9-5/8"
245mm
22-1/2"
572mm
75mm
2"
11-1/4"
7"
178mm
286mm
5-7/8"
Stove Back
28-11/16"
729mm
11-1/4"
286mm
5-1/2"
140mm
Clean-Out
Tee
1-9/16"
40mm
23-1/8"
507mm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents