Maintenance; Front Glass Enclosure Panel, Removal And Installation - Lennox Hearth Products EBVCLNE Homeowner's Care And Operation Instructions Manual

B-vent multi-open elite series
Hide thumbs Also See for EBVCLNE:
Table of Contents

Advertisement

Manual-Reset Safety Limit Switch
This appliance is equipped with a manual-
reset blocked flue safety limit switch. Refer to
Figure 5 for its location. If, during appliance
operation, the flame goes out (independently
of the burner on/off wall switch), it may be due
to the operation of this safety limit switch.
First allow the appliance to cool, then reset
the safety switch by pushing the red reset
button on it.
A - To access the blocked flue safety switch
when top radiant panel is not covered with
non-combustible material:
1 - Lift up and remove top radiant panel/
eyebrow assembly on the control side of
unit.
2 - Reach between the cabinet side and the
firebox side wall and locate the blocked flue
safety switch.
3 - Push the red reset button on the switch.
The applilance should then relight and remain
lit. If this does not occur, turn off the appli-
ance and call a qualified service technician.
SAFETY SWITCH LOCATION (EBVCL SHOWN)
EVBST and EBVPF Safety Switch Location Also as Shown;
FIREBOX BOX
SIDE WALL
SAFETY SWITCH
BRACKET SECURING SCREW
Figure 5
6
B - To access the blocked flue safety switch
when top radiant panel is covered with non-
combustible material:
Note: This procedure should only be performed
by a qualified service technician.
1 - Lower bottom hinged panel on the con-
trol side of the fireplace. Remove the glass
enclosure panel as described on page 8,
under "Remove the front glass enclosure
panel as follows:", Steps 2, 3, 4, 5 and 6.
2 - Remove the side baffle securing screws
(5) and then remove the baffle.
3 - Remove the safety switch bracket secur-
ing screws (2), and pull the switch/bracket
assembly through the side panel slot.
4 - Push the red reset button on the switch.
5 - Reinstall the switch/bracket assembly.
6 - Reinstall the side baffle.
7 - Reinstall front glass door.
8 - Raise the bottom hinged panel.
The appliance should then relight and remain
lit. If this does not occur, check unit for a
blocked flue condition.
EBVCR Location on Left End of Fireplace.
FIREBOX SIDE BAFFLE SECURING SCREW
FIREBOX SIDE BAFFLE
TOP RADIANT PANEL
AND EYEBROW
CABINET SIDE WALL
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
MANUALLY-RESET
SAFETY LIMIT SWITCH

Maintenance

The appliance and venting system should be
thoroughly inspected before initial use and at
least annually by a qualified service techni-
cian. However, more frequent periodic inspec-
tions and cleanings should be performed by
the homeowner. Homeowner must contact a
qualified service technician at once if any
abnormal condition is observed.
Refer to the maintenance schedule for mainte-
nance tasks, procedures, periodicity and by
whom they should be performed. Always
verify proper operation of the appliance after
servicing.
IMPORTANT: TURN OFF GAS AND ANY ELEC-
TRICAL POWER BEFORE SERVICING THE
APPLIANCE.
Front Glass Enclosure Panel, Removal
and Installation.
WARNING: NEVER OPERATE THE AP-
PLIANCE WITHOUT THE GLASS ENCLO-
SURE PANELS IN PLACE AND SECURE.
DO NOT OPERATE APPLIANCE WITH
FRONT GLASS CRACKED, BROKEN OR
MISSING. REPLACEMENT MUST BE
DONE BY A LICENSED OR QUALIFIED
SERVICE TECHNICIAN.
These fireplaces are designed to operate only
with the glass enclosure panels properly in-
stalled. Generally the glass enclosure panels
should not be removed except to gain access
to the components within the firebox, and the
appliance may only be operated without the
front glass enclosure panel in place for very
brief periods of time during initial appliance
checkout and adjustment.
During this appliance checkout and adjustment
period, a potential safety hazard exists - EXER-
CISE EXTREME CAUTION to prevent the occur-
rence of any burn injuries from the exposed
flames or hot surfaces. Also note, that while the
front glass enclosure panel (or any of the panels)
is removed, the flame appearance will appear to
be smaller than normal.
WARNING: HANDLE THE GLASS WITH
EXTREME CARE! TEMPERED GLASS IS
SUSCEPTIBLE TO DAMAGE (SCRATCHES,
FOR EXAMPLE) – HANDLE GLASS DOOR
(GLASS ENCLOSURE PANEL) GENTLY
WHILE REINSTALLING IT.

Hide quick links:

Advertisement

Table of Contents
loading