Lighting Instructions - Millivolt; To Turn Off Gas To Appliance - Lennox Hearth Products EBVCLNE Homeowner's Care And Operation Instructions Manual

B-vent multi-open elite series
Hide thumbs Also See for EBVCLNE:
Table of Contents

Advertisement

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. This appliance has a pilot which must be lighted with a piezo
ignitor. When lighting the pilot, follow these instructions
exactly.
B. BEFORE OPERATING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Extinguish any open flame.
• Open windows.
• Do not light any appliance.
• Do not touch any electrical switches.
1. STOP! Read the safety information above on this page.
2. Access the lower control compartment.
3. Turn remote wall switch to "OFF."
4. Verify main line shut-off valve is open.
5. Push in gas control knob slightly and turn clockwise
to "OFF."
Note: Knob cannot be turned from "PILOT" to "OFF"
unless the knob is pushed in slightly. Do not force.
1. Turn remote wall switch "OFF." The pilot will remain lit for
normal service.
2. For complete shutdown, turn remote wall switch to "OFF."
3. Access the lower control compartment.
16
LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
IN
OUT
10. Close lower control compartment.

TO TURN OFF GAS TO APPLIANCE

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone.
• If your gas supplier cannot be reached, call the fire depart-
ment.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand,
do not try to repair it, call a qualified service technician. Force
or attempted repair may result in a fire or an explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
6. Wait five (5) minutes to clear out any gas. If you then smell gas,
STOP! Follow "B" in the safety information above on this page. If you
do not smell gas, go to the next step.
7. Push in gas control knob slightly and turn counterclockwise
to "PILOT."
8. Push in control knob all the way and hold in. Immediately light the
pilot by triggering the spark ignitor (pushing the button) until pilot
lights. Continue to hold the control knob in for about 1
after the pilot is lit. Release knob and it will pop back up. Pilot should
remain lit. If it goes out, repeat steps 5 through 8.
• If knob does not pop up when released, stop
and immediately call your service technician
or gas supplier.
• If pilot will not stay lit after several
tries, turn the control knob to "OFF"
and call your service technician or
gas supplier.
9. Turn gas control knob counterclockwise
to "ON."
4. Depress gas control knob slightly and turn clockwise
to "OFF." Do not force.
5. Close lower control compartment.
minutes

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents