• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
• Carefully supervise children in the
same room as appliance.
• If small children are present in the home, it
is recommended that this appliance be fi tted
with a Firescreen kit. See Page 20 for ordering
information.
WARNINGS
Listed to standards:
ULC-S610 & UL-127
Report No. 304-7213
EPA Cert. No. 609
INSTALLATION AND

OPERATING INSTRUCTIONS

MONTECITO ESTATE™
EPA Wood-Burning Fireplace
P/N 850,038M REV. A 05/2006
MODEL
MONTEST
This installation manual will enable you to obtain a safe, effi cient and de-
pendable installation of your fi replace system. Please read and understand
these instructions before beginning your installation.
Do not alter or modify the fi replace or its components under any circum-
stances. Any modifi cation or alteration of the fi replace system, including
but not limited to the fi replace, chimney components and accessories,
may void the warranty, listings and approvals of this system and could
result in an unsafe and potentially dangerous installation.
A French manual is available upon request. Order P/N 850,038CF
Ce manuel d'installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 850,038CF.
• The fi replace cannot be operated without a door.
Consult your dealer to select the correct door
model.
• Important! To assure proper alignment of glass
doors: Install this fi replace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
• Install the fi replace only as described in these
instructions.
PIMONTEST
WARNINGS

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products MONTECITO ESTATE MONTEST

  • Page 1: Operating Instructions

    LENNOX HEARTH PRODUCTS RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNINGS • Hot! Do not touch! The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the appli- ance. Severe burns may result.
  • Page 2: Safety Rules

    IMPORTANT! GENERAL SAFETY PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY RULES BEFORE YOUR FIRST FIRE. WARNING Never leave children unattended when there is a fi re burning in the fi replace. IMPORTANT When burning wood, use SOLID NATURAL DRY WELL-SEASONED WOOD ONLY. Hardwoods are recommended (soft woods tend to burn very quickly).
  • Page 3: Table Of Contents

    CONGRATULATIONS! In selecting this LENNOX wood-burning appliance you have chosen one of the fi nest fi replaces available. The Montecito Estate™ is a clean burning EPA certifi ed fi replace that is designed to provide you dependable service as well as warmth and enjoyment for many years to come.
  • Page 4: Combustion Control

    COMBUSTION CONTROLS Primary Air & Air Boost Controls There is no fl ue damper in the Montecito Es- tate™. As is common with air tight appliance, the combustion air control sets the fl ow of air entering the fi rebox. This allows for a more precise control of the fi...
  • Page 5: Refueling For Best Performance

    Slow Combustion When the air combustion control is completely closed, the fi replace is in a slow combustion phase. If the hearth is hot enough, slow com- bustion will not extinguish the fi re, but there will be a noticeable change in the fl ame pattern. The fl...
  • Page 6: Important Cautions

    IMPORTANT CAUTIONS A. Do not block the hot air vents to the fi re- place as this will cause the fi replace to overheat. B. Never use gasoline, kerosene, charcoal lighter fl uid or similar liquids to start or rekindle a fi re in this fi replace. Keep all such liquids well away from the fi...
  • Page 7: Door Installation

    “tight” in all areas, since a small amount of leakage is not hazardous or detrimental to the performance of your fi replace. WARNINGS • Use only a Lennox Hearth Products glass doors, specifi cally designed for the Montecito Estate fi replace.
  • Page 8: Fireplace Installation

    FIREPLACE INSTALLATION Locating The Montecito Estate™ The best location to install your fi replace is determined by considering the location of windows, doors, and the traffi c fl ow in the room where the fi replace is located, allowing space in front of the unit for the hearth extension and the mantel, and taking into consideration the location of the hot air ducts (optional), outside air kit and chimney.
  • Page 9 Header 2” x 3” Min. Plywood 7’ Min. Rough Framing Face (unfi nished shown) FRAMING DIMENSIONS Fireplace Opening Width 46-3/8” 1178 mm 49-1/2” 1257 mm 42-3/4” 1086 mm 20-7/8” 530 mm 93-7/8” 2384 mm 26-1/4” 47” 1194 mm 27-3/4” 705 mm 66-3/8”...
  • Page 10: Hot Air Ducting Installation

    FACING IMPORTANT The facade must be removable once installed. The facade is designed to overlap any facing material installed on the front of the fi replace. If thicker material is installed, use the facade as a template and make sure it can be easily removed for servicing.
  • Page 11 Frame Grille Figure 16 When installing the double outlet system, the hot air outlets can be installed in the same room as the fi replace, or one or both of the outlets can be installed in adjacent or upper rooms. Installing the ducts at dif- ferent elevations will tend to exhaust more heat out of the higher outlet (Figure 17).
  • Page 12: Outside Air Kit

    OUTSIDE AIR KIT It is mandatory to install an outside air connection to the Montecito Estate™. The following components are required and are included with the fi replace: - Outside air kit (includes 40 inch fl ex that goes up to ten (10) feet long) - 4”...
  • Page 13: Chimney System

    THE CHIMNEY SYSTEM Chimney Installation Notes 1. If possible, install an interior chimney as it will provide better per- formance. In areas with continuous temperatures below 18°C (0°F), the use of an exterior chimney increases the likelihood of operating problems such as low draft, high rate of creosoting, and poor start-up characteristics.
  • Page 14: Chimney Installation Instructions

    CHIMNEY INSTALLATION INSTRUC- TIONS 1. Cut and frame the holes in the ceiling, fl oor and roof where the chimney will pass (see Figure 22). Use a plumb bob to line up the center of the holes. The sizes are indicated in Table 2 for the fl...
  • Page 15: Offset Chimney Installation

    CHIMNEY MODEL ACBI Chimney Collar Flashing Figure 25 Roof Down Slope Hole Size DEGREE OF SLOPE Secure Temp™ S2100+ Nova Temp™ HT6000+ Secure Temp GX Roof Pitch 7” 15” (380 mm) 2/12 15-3/8” (390 mm) 4/12 16-1/8” (410 mm) 6/12 16-7/8”...
  • Page 16 Chimney Elbow Offset & Height 8” 3” (76 mm) 15º 20-3/4” (527 mm) S2100+ 7-1/2” HT6000+ (191 mm) 7” 30º 16-1/2” (419 mm) 10” 45º (254 mm) Canada 17-9/16” Only (446 mm) Chimney Elbow Offset & Height ---- ---- 15º ---- ---- ACBI...
  • Page 17 Figure 28 OFFSET CHIMNEY INSTALLATION WITH WALL PENETRATION Rain Cap Outside Wall Framing 2” x 3” Figure 29 OFFSET CHIMNEY INSTALLATION Support Straps Chimney ACBI ACBI Starter Section Insulated Wall Radiation Shield NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Straps Collar Roof Support...
  • Page 18: Angled Wall Radiation Shield

    ANGLED WALL RADIATION SHIELD (XRSMI30 and AC10RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled fi restop or wall radiation shield must be installed. Only one is required. Note: 45º angle for Canada only (XRSMI45). In cold climate locations (climates where temperatures will fall below 32º...
  • Page 19: Masonry Application Instructions

    INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION WARNING: Before starting the installation, the masonry chimney must be inspected by a qualifi ed chimney sweep. The following requirements must be respected: 1. The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing bricks that could inhibit correct installation of the liner.
  • Page 20: Installation Accessories

    OPTIONAL INSTALLATION ACCESSORIES Installation Accessories Description Facades (Required - Order Separately) Montecito Estate™ Facade Black, MEFBK Montecito Estate Facade Brushed Nickel, MEFBN Montecito Estate Facade Hammered Steel, MEFMC Doors - (Required - Order Separately) Montecito Estate Doors Black, MECBK Montecito Estate Doors Brushed Nickel, MECBN Montecito Estate Doors Hammered Steel, MECMC Outside Air Kit (included with fi...
  • Page 21 CHIMNEY - PARTS AND COMPONENTS LISTS ACBI Chimney* (7” I.D., 13” O.D. AC - Air Cooled) * AC Chimney is NOT recommended at elevations above 4,000 feet or in cold climates (climates where temperatures will fall below 32° F / 0° C). Description One of the following adaptors is required if installing an AC chimney system...
  • Page 22: Replacement Parts

    REPLACEMENT PARTS LIST Montecito Estate™ - Replacement Parts Description Blower Blower Motor Speed Control Snap Disc, Blower Baffl e refractory (2 pieces) (top of fi rebox) Top Hearth Insulation Front Refractory Bricks Back Refractory Brick Right Side Refractory Bricks - Back Right Side Refractory Bricks - Front Left Side Refractory Bricks - Back Left Side Refractory Bricks - Front...
  • Page 23: Clearances

    NOTES...
  • Page 24: Warranty

    HOW TO REGISTER A CLAIM AGAINST WARRANTY In order for any claim under this Warranty to be valid, LHP must be notified of the claimed defect in writing to Lennox Hearth Products, attention Customer Service Department, 1110 West Taft Avenue, Orange, CA. 92865, as soon as reasonably possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.