Lennox Hearth Products LENNOX MPE-33R Installation And Operating Instructions Manual

Lennox Hearth Products LENNOX MPE-33R Installation And Operating Instructions Manual

Merit plus series 33" electric fireplace

Advertisement

LENNOX HEARTH PRODUCTS
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
INSTALLATION AND

OPERATING INSTRUCTIONS

®
MERIT PLUS SERIES
33" Electric Fireplace
P/N 850,032M REV. C 10/2006
MODEL:
MPE-33R
This manual will enable you to obtain a safe, effi cient and dependable
installation and operation of your electric fi replace. Please read and
understand these instructions before beginning your installation.
Do not alter or modify this fi replace or its components under any circum-
stances. Any modifi cation or alteration of the fi replace system, including
but not limited to the fi replace and accessories, may void the warranty,
listings and approvals of this system and could result in an unsafe and
potentially dangerous installation.
IMPORTANT! IF OPTIONAL GLASS DOORS ARE PURCHASED, TO
ASSURE PROPER ALIGNMENT, INSTALL THIS FIREPLACE IN A
SQUARE AND PLUMB CONDITION, USING SHIMS AS NECESSARY
AT SIDES. THIS APPLIANCE IS MOUNTED ON RUBBER FEET TO
ENSURE ADEQUATE AIR CIRCULATION BENEATH FIREPLACE.
DO NOT BLOCK AIRFLOW AT THE BOTTOM AIR INTAKES.
INSTALLER: DO NOT DISCARD THIS MANUAL
PLEASE LEAVE FOR THE HOMEOWNER
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER
APPLIANCE.
A French manual is available upon request. Order P/N 850,032CF
Ce manuel d'installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 850,032CF.
®
C
US
Report # C1482763

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products LENNOX MPE-33R

  • Page 1: Operating Instructions

    LENNOX HEARTH PRODUCTS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE INSTALLATION AND OPERATING INSTRUCTIONS ® MERIT PLUS SERIES 33" Electric Fireplace P/N 850,032M REV. C 10/2006 MODEL: MPE-33R This manual will enable you to obtain a safe, effi cient and dependable installation and operation of your electric fi...
  • Page 2: Important Safety Information

    IMPORTANT SAFETY AND WARNIING INFORMATION READ THIS MANUAL IN ITS ENTIRETY AND UNDERSTAND THESE RULES TO FOLLOW FOR SAFETY. WARNING If the information in this manual is not followed exactly, an elec- trical shock or fi re may result causing property damage, per- sonal injury or loss of life.
  • Page 3: Table Of Contents

    CONGRATULATIONS! In selecting this LENNOX Merit Plus electric fi replace, you have chosen the fi nest and most dependable fi replace found anywhere. A beautiful and prestigious addition to the fi nest homes. Welcome to a Family of hundreds of thousands of satisfi ed LENNOX Fireplace Owners.
  • Page 4: Framing Specifi Cations

    FRAMING SPECIFICATIONS 25-5/8 " (651 mm) 36-1/4 " (921 mm) 35-1/4 " (895 mm) 51-1/4 " (1302 mm) Electrical Junction Corner View Note: Framing dimensions are calculated for a nailing fl ange depth of 1/2" Figure 2 FIREPLACE SPECIFICATIONS Electrical Access Cover Power Cord 32 "...
  • Page 5: Clearances

    FIREPLACE SPECIFICATIONS Cat. No. H3427 Model: MPE-33R Description: Merit Plus Electric Fireplace, 33” Radiant Shipping Weight: 81 lb.'s (36.75 KG) Packaging: 41” x 17 3/4” x 33 1/2” (1040 mm x 451 mm x 850 mm) 14.1 cu. ft. Power Requirements: (120 Volt, 60 Hz.) Rated Wattage - 1600 Watts Amperage - 13.33 Amps...
  • Page 6: Final Finishing

    FINAL FINISHING Materials such as brick and tile can be extended down to the top of the fi replace. Do not extend down, covering the outlet or glass enclosure panel (optional kit). There are a wide variety of “fi nished looks” for these fi...
  • Page 7: Remote Control Operation

    REMOTE CONTROL OPERATION: REMOTE CONTROL POWER ON/OFF DISPLAY ON/OFF Dimmer Brighter EMBERS HEATER ON/OFF TEMP. CONTROL HIGH MED. LOW FLAME HIGHER LOWER • When using the remote control, the power on/off switch inside the body and the wall switch (optional kit) must be on the OFF position.
  • Page 8: Maintenance

    MAINTENANCE This appliance has been designed to provide many years of trouble-free service. The com- ponents that will need to be serviced have been kept to a minimum. Periodic dusting of the fi replace is all that should be required. CAUTION Disconnect power before attempting any maintenance or...
  • Page 9 Replacing Light Bulbs WARNING The fi replace must be unplugged/ disconnected from the power supply prior to any maintenance or cleaning in order to reduce the risk electric shock or fi re. WARNING The halogen light bulbs in your fi replace can become extremely hot.
  • Page 10: Wiring Diagrams

    WIRING DIAGRAM - 120 VOLT Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance on the left side. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DAN- GEROUS APPLIANCE OPERATION.
  • Page 11 WIRING DIAGRAM - 240 VOLT Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance on the left side. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DAN- GEROUS APPLIANCE OPERATION.
  • Page 12 WALL THERMOSTAT & WALL SWITCH WIRING DIAGRAMS (optional kits, see Page 18) GREEN GROUND • When using the manual control panel power on/off switch, the outside power on/off switch (optional wall switch kit) must be in the OFF position. • When using the outside power on/off switch (optional wall switch), the manual control panel power on/off switch must be in the OFF position.
  • Page 13 Installing Wall Thermostat (optional kit, see Page 18) Wire the wall thermostat prior to installing the fi replace. WALL THERMOSTAT WIRING (24 VAC): Install Wall Thermostat per instructions provided with kit and per the following information: 1. Turn off circuit breaker. 2.
  • Page 14 Power On/Off Wall Switch Installation (optional kit, see Page 18) Wire the wall switch prior to installing the fi replace. WALL SWITCH WIRING (24 VAC): Install Wall Switch per instructions provided with kit and per the following information: 1. Turn off circuit breaker. 2.
  • Page 15: Troubleshooting

    TROUBLESHOOTING Symptom Possible Causes 1. Fireplace turns off and will not Fireplace has overheated. turn on and an audible beeping noise can be heard. 2. Flame is fi xed (unmoving). Wiring may be loose or the fl ame motor may be defective. 3.
  • Page 16: Replacement Parts

    REPLACEMENT PARTS ITEM Bulb Kit, (10 Each 35w Halogen) Side Frames, 1 Left And 1 Right Circuit Board Nailing Flange Kit, (4 Each) Glass Brick Panel Glass Retaining Bracket Kit: Left, Right, & Top Grate Assembly Blower, Heating Element & Access Panel Assembly Fuse Plate Assembly (5 each) Flame Cylinder Assembly Flame Motor...
  • Page 17 REPLACEMENT PARTS COMPONENT DIAGRAMS - POWER ON/OFF DISPLAY ON/OFF Brighter Dimmer EMBERS HEATER ON/OFF TEMP. CONTROL HIGH MED. LOW FLAME HIGHER LOWER MPE-33R NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Front View...
  • Page 18: Optional Accessories

    ACCESSORY COMPONENTS The following items are available for use with this appliance. Wall Switch Kit Cat. No. Model Description 85L87 FWSK Wall Switch Kit, White Glass Enclosure Kit These glass enclosure panels are a one-piece panel, which have a bi-fold “look” as shown below.
  • Page 19 NOTES NOTE: THIS PAGE LEFT BLANK INTENTIONALLY NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
  • Page 20 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products. Consult your local distributor for fi replace code information. Printed in U.S.A. © LENNOX HEARTH PRODUCTS 2005 REV. C 10/2006 P/N 850,032M...

This manual is also suitable for:

Mpe-27

Table of Contents