• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
• Carefully supervise children in the
same room as appliance.
• If small children are present in the home, it is
recommended that this appliance be fitted with
a screen door or screen panel kit. See Page 9
for ordering information.
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
WARNINGS
OTL Report No. 116-F-04-5
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
HOMEOWNER'S CARE AND

OPERATION INSTRUCTIONS

DIRECT VENT MULTI-OPEN
ELITE
VENTED GAS FIREPLACE HEATERS - DIRECT VENT MODELS
P/N 875,022M REV. C 03/2007
MODELS
M
l i
v i l
t l o
M
o
e d
E
D
V
S
T
N
M
E
D
V
C
E
D
V
S
T
P
M
E
D
V
C
E
D
V
P
F
N
M
E
D
V
C
E
D
V
P
F
P
M
E
D
V
C
A French manual is available upon request. Order Form Number
875,022CF.
Ce manuel d'installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 875,022CF.
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où
vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un qualifié
installeur, agence de service ou le fournisseur de gaz.
®
SERIES
s l
E
e l
r t c
n o
c i
M
R
N
M
E
D
V
S
T
N
E
E
R
P
M
E
D
V
P
F
N
E
E
L
N
M
L
P
M
o
e d
s l
D
V
C
R
N
E
D
V
C
L
N
E
1

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products ELITE ENFPVDE

  • Page 1: Operation Instructions

    WARNINGS • Hot! Do not touch! The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the appli- ance. Severe burns may result. • Carefully supervise children in the same room as appliance.
  • Page 2: Table Of Contents

    CONGRATULATIONS! In selecting this LENNOX Direct-Vent Gas Appliance you have chosen the finest and most dependable fireplace to be found anywhere. Its a beautiful, prestigious alternative to a wood burning fireplace. Welcome to a Family of tens of thousands of satisfied LENNOX Fireplace Owners.
  • Page 3: Operation/Care Of Your Appliance

    The following table shows the units' orifice size for the elevations indicated. i f i " 5 Maximum manifold pressure is 3.5 in. w.c. (0.87 kPa) for natural gas and 10 in. w.c. (2.49 kPa) for LP/Propane gas. Do not use these appliances if any part has been under water.
  • Page 4: Variable Flame Adjustment

    Variable Flame Height Adjustment Inlet Pressure Port Manifold Pressure Port SIT Millivolt Gas Valve Figure 2 Refer to Figure 1 for access to the gas control valve. Millivolt appliances will be fitted with the gas control valve shown in Figure 2 . Appliances with electronic sys- tems will be fitted with the electronic valve shown in Figure 3 .
  • Page 5: Maintenance Schedule

    Maintenance Schedule Annually (Before the onset of the Burning Season) Maintenance Task Inspecting/Cleaning Burner, Logs and Controls Check Flame Patterns and Flame Height Inspecting/Cleaning Pilot Burner and the Two Main Burners Checking Vent System Appliance Checkout Periodically (After the Burning Season) Maintenance Task Cleaning Firebox Interior Check Flame Patterns and Flame Height...
  • Page 6: Burner Adjustments

    WARNING: HANDLE THE GLASS WITH EXTREME CARE! DO NOT STRIKE DOOR. TEMPERED GLASS IS SUSCEP- TIBLE TO DAMAGE (SCRATCHES, FOR EXAMPLE) – HANDLE GLASS DOORS (GLASS ENCLOSURE PANELS) GENTLY WHILE REINSTALLING THEM. WARNING: DO NOT ATTEMPT TO SUB- STITUTE THE MATERIALS USED ON THESE DOORS, OR REPLACE CRACKED OR BROKEN GLASS WITH ANY MATERI- ALS OTHER THAN THOSE PROVIDED BY...
  • Page 7: Glowing Ember Placement

    Operate the appliance for a period of time as the effect diminishes, ensuring that the appliance does not develop sooty flames. When satisfied that the appliance operates prop- erly, proceed to finish the installation. Leave the control knob in “ON” position and turn the remote switch “OFF.”...
  • Page 8: Electronic Appliance Checkout

    If you encounter any problems or have any questions concerning the installation or appli- cation of this system, please contact your dis- tributor, or Lennox directly: LENNOX HEARTH PRODUCTS 1110 West Taft Avenue • Orange, CA 92865 e t i 120 VAC - Black...
  • Page 9: Accessory Components

    ACCESSORY COMPONENTS s t i Door Frame Kits A decorative door frame kit is available for use with these appliances. The DTK is designed to attach directly to the front face of the appli- ance at its extreme edges. The DTK provides a picture frame finish for the appliance.
  • Page 10 ACCESSORY COMPONENTS CONTINUED Remote Control System (Standard) H0249 Standard Remote Control System The Model RCL (Standard) Remote Control System, features a simplistic on/off control function for the fireplace. This model includes a hand-held transmitter, a remote receiver with wall-mount coverplate and all hardware required to install the unit.
  • Page 11 ACCESSORY COMPONENTS CONTINUED Charcoal Finish Louvers Kits Decorative louvers are available for use with all Multi-Open Series appliances. These louvers are designed to replace the standard radiant panels that are provided with the appliance. These kits include a charcoal finish top 3-piece assembly and a bottom 3-piece assembly.
  • Page 12 ACCESSORY COMPONENTS CONTINUED s t i 2-Piece Polished Brass and Brushed Stainless Louvers Kits Decorative louvers are available for use with all Multi-Open Series appliances. These louvers are designed to replace either the middle char- coal louver of each set or the charcoal louver in each set closest to the glass door.
  • Page 13 ACCESSORY COMPONENTS CONTINUED s t i The brickaded liner kits include ceramic panels as shown here. The panels have brick-like fea- tures in relief. H0778 (Rear Vent) H0778 (Top Vent) H0779 (Rear Vent) H0780 & H0781 (Rear Vent) NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. H0779 (Top Vent) H0780 &...
  • Page 14 ACCESSORY COMPONENTS CONTINUED Style View Doors - Style View Doors come in 4 beautiful styles. They are easy to install and will not require hardware to attach them to the standard glass door frame. The door includes heavy duty magnet door latches and functional twin-pane doors. Arch Design Arch Pane Design ARCH DESIGN KITS...
  • Page 15 ACCESSORY COMPONENTS CONTINUED Style View Doors Continued - Style View Doors also come in a Tall Arch Pane Design. Two distinctive grille kits, the “Crescents” and “Sunrise” design, are also offered seperately. They are easy to install and will not require hardware to attach them to the standard glass door frame. The door includes heavy duty magnet door latches and functional twin-pane doors.
  • Page 16: Lighting Instructions - Millivolt

    WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted with a piezo ignitor. When lighting the pilot, follow these instructions exactly.
  • Page 17 INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE AVERTISSEMENT : SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE. A.
  • Page 18: Lighting Instructions - Electronic

    WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. When lighting the appliance, follow these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas.
  • Page 19 INSTRUCTIONS D’ALLUMAGE — ELECTRONIC POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE AVERTISSEMENT: SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE. A.
  • Page 20: Troubleshooting Guide - Millivolt

    TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM ote: Before troubleshooting, make sure that the appliance main line gas shut-off valve and the gas control valve are in the "OPEN" position and the burner ON/OFF switch is in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. SYMPTOM 1.
  • Page 21: Troubleshooting Guide - Electronic

    TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM ote: Before troubleshooting, make sure that the appliance main line gas shut-off valve and the gas control valve are in the "OPEN" position and the burner ON/OFF switch is in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. SYMPTOM POSSIBLE CAUSES 1.
  • Page 22: Replacement Parts List

    , t n e l t , e l , e l , e l , t e , t e , t e , t e c t i REPLACEMENT PARTS LIST . n i . n i . n i .
  • Page 23 REPLACEMENT PARTS t o l t o l t o l i f i c i t GAS CONTROLS — SIT MILLIVOLT t i n ) l e GAS CONTROLS — HONEYWELL ELECTRONIC l l e t o l t i n ) t i i f i c i t...
  • Page 24 REPLACEMENT PARTS Cabinet Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2003 by Lennox Hearth Products P/N 875,022M REV.