Lennox Hearth Products Crestline LSBV-3628EN Installation Instructions Manual
Lennox Hearth Products Crestline LSBV-3628EN Installation Instructions Manual

Lennox Hearth Products Crestline LSBV-3628EN Installation Instructions Manual

Crestline series b-vented gas appliances

Advertisement

Quick Links

LENNOX HEARTH PRODUCTS
This appliance may be installed in an aftermarket perma-
nently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance
is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other
gases, unless a certified kit is used.
In the Commonwealth of Massachusetts & New York:
• Installation must be performed by a licensed plumber or
gas fitter.
See Table of Contents for location of additional New York
& Commonwealth of Massachusetts requirements.
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.
Do not store or use gasoline or other flammable
vapors or liquids in the vicinity of this or any other
appliance.
What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches, do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour
consultation ultérieure.
INSTALLATION
INSTRUCTIONS
B-VENTED GAS APPLIANCES
P/N 850,042M REV. A 12/2008
MODELS
Millivolt Models
LSBV-3628MN
LSBV-3628MP
LSBV-3628MN-H
LSBV-3628MP-H
LSBV-4228MN
LSBV-4228MP
LSBV-4228MN-H
LSBV-4228MP-H
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉES DANS CETTE NOTICE
POUR RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE
D'EXPLOSION OU POUR ÉVITER TOUT DOMMAGE
MATÉRIEL, TOUTE BLESSURE OU LA MORT.
Ne pas entreposer ni utiliser d'essence ni d'autre
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bátiment
où vous vous trouvez.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incendies.
L'installation et l'entretien doivent être assurés par
un installeur ou un service d'entretien qualifié ou par
le fournisseur de gaz.
A French manual is available upon request. Order P/N 506223-07.
Ce manuel d'installation est disponible en francais, simplement en faire
la demande. Numéro de la pièce 506223-07.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
CRESTLINE
Electronic Models
LSBV-3628EN
LSBV-3628EN-H
LSBV-4228EN
LSBV-4228EN-H
Portland
OTL Report No. 116-F-45-5
US
SERIES
1

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products Crestline LSBV-3628EN

  • Page 1 LENNOX HEARTH PRODUCTS This appliance may be installed in an aftermarket perma- nently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Packaging ... page Introduction ... page Massachusetts and New York Requirements ... page General Information ... page Location ... page Appliance Specifications ... page Clearances ... page Gas Vent Rule ... page Framing Specifications ... page Assembly Steps ... page Installation ...
  • Page 3: Location

    Nominal operating pressures for the manifold side of the gas control system are; 3.5 inches water column (0.87 kPa) for natural gas mod- els and 10 inches water column (2.49 kPa) for propane gas models. Do not use these appliances if any part has been under water.
  • Page 4: Appliance Specifications

    APPLIANCE SPECIFICATIONS 7-3/32 28-15/32 LSBV-36: 37 5-3/4 LSBV-42: 43 Gas Line Or Switch Wire Outlet 1-7/16 8-7/8 Left Side View 8-15/32 Figure 2 12-15/32 47-9/32 41-5/16 LSBV-36: 41-3/4 LSBV-42: 47-3/4 Front View Combustion Air Inlet 7-7/16 Junction Location Gas Line 15-27/32 Or Switch Wire Outlet...
  • Page 5: Framing Specifications

    FRAMING SPECIFICATIONS Header Fireplace Framing Figure 4 Back Wall of Chase/Enclosure Combustion Including Finising Materials if any Rough Framing Face (Unfinished Shown) Inside Chase Figure 5 Back Wall of Chase/Enclosure Including Finishing Materials Optional Locations if any Combustion FATO Adapter (Optional) Rough Framing Face (Unfinished Shown)
  • Page 6 4. Use this information and consult your local building code to determine if you need addi- tional support. If you plan to raise the fireplace and hearth extension, build the platform assembly then position fireplace and hearth extension on top. Secure the platform to the floor to prevent possible shifting.
  • Page 7: Field Wiring

    Step 4. Install the Vent System & Exterior Termination - Slip a 10" (254 mm) B-Vent system over the appliance collar ( Figure 10 ) and secure with four sheetmetal screws (# 8 or larger). Minimum overall height of the vent system and appliance must be 12' (3.66 m) vertical (no offset) or 17' (5.18 m) when an offset up to 45 degrees from the vertical is used.
  • Page 8: Connecting Gas Line

    PILOT BURNER WHITE IGNITER-SENSOR ASSEMBLY BLUE GROUND CONNECTOR ELECTRONIC IGNITION CONTROL BOARD 1. Route a 3-wire 120V 60Hz power supply line to the appliance junction box wires and ground (Figures 13 ). 2. After wiring is complete, replace the appli- ance junction box cover and secure with the hex head screws previously removed.
  • Page 9 Note: Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be wired to a terminal that is opposite (across the outlet) the point where the white supply wire is connected (Figure 15 ). Green Wire Ground Connection White...
  • Page 10: Appliance Operation

    Figure 17 Refer to the Homeowners Care and Operation Instructions for detailed log description and placement instructions. Log set shown in this document (Figure 17 ) is typical, installation of all sets are similar. APPLIANCE OPERATION Step 9. Checking the System – With gas line installed run initial system checkout before closing up the front of the unit.
  • Page 11: Millivolt Appliance Checkout

    Millivolt Appliance Checkout The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge. The top 3/8" (9 mm) at the pilot generator (thermopile) should be engulfed in the pilot flame.
  • Page 12: Finishing Requirements

    Combustible Mantel and Trim (See Note) Max. 18 5/8" 11-3/8" Min. 18" 12" Min. 10" Min. Non-Combustible Material Note: Mantel At Minimum Height Should Be Affixed to Framing Hinge Posts At Right And Left Of The Fireplace. Do Not Use Molly Bolts In Front Of The Fireplace. Figure 23 FINISHING REQUIREMENTS Wall Details and Combustible Mantels...
  • Page 13 INSTALLATION ACCESSORIES CONTINUED Adjustable Flashing 1/12 - 7/12 10" Gas Vent 17/12 - 12/12 Storm Collar BV 10" 10KFC Rain Cap B-Vent 10KCGV Chase Top Shroud Kits (Arch Top 3 x 3) H1988 CTSA-33 (Open Top 3 x 3) H1985 CTS0-33 (Open Top 4 x 4) H1987...
  • Page 14: Gas Conversion Kits

    Gas Conversion Kits WARNING: THIS CONVERSION KIT SHALL BE IN- STALLED BY A QUALIFIED SERVICE AGENCY IN AC- CORDANCE WITH THE MANUFACTURER'S INSTRUC- TIONS AND ALL APPLICABLE CODES AND REQUIRE- MENTS OF THE AUTHORIZED AGENCY HAVING JU- RISDICTION. IF THE INFORMATION IN THESE IN- STRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE, EXPLOSION OR PRODUCTION OF CARBON MONOX- IDE MAY RESULT CAUSING PROPERTY DAMAGE,...
  • Page 15 Step 5. Millivolt Systems – Attach manom- eter to the manifold side pressure test fitting and verify manifold pressure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.0 inches water column (2.49 kPa) for pro- pane gas. Step 6.
  • Page 16 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2007 by Lennox Hearth Products P/N 850,042M REV.