Lennox Hearth Products Cambria Installation And Operation Instructions Manual
Lennox Hearth Products Cambria Installation And Operation Instructions Manual

Lennox Hearth Products Cambria Installation And Operation Instructions Manual

Wood-burning fireplaces

Advertisement

Quick Links

SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
Carefully supervise children in the
same room as appliance.
If small children are present in the home, it is
recommended that this appliance be fitted with
a firescreen kit.
WARNINGS
Listed to standards:
ULC-S610 and UL-127
Report No. 3092554
PICAMBRIA-A REV. 3 NOV 2008
INSTALLATION AND

OPERATION INSTRUCTIONS

CAMBRIA™
Wood-Burning Fireplace
P/N 850,057M REV. C 11/2008
MODEL
CAMBRIA
This installation manual will enable you to obtain a safe, efficient
and dependable installation of your fireplace system. Please read
and understand these instructions before beginning your installation
or operating the fireplace.
CAUTION: Do not alter or modify the fireplace or its components under
any circumstances. Any modification or alteration of the fireplace
system, including but not limited to the fireplace, chimney components
and accessories, may void the warranty, listings and approvals of
this system and could result in an unsafe and potentially dangerous
installation.
Lennox Hearth Products wood-burning fireplaces are designed for use
as a supplemental heater. They are not intended for continuous use
as a primary heat source.
The fireplace cannot be operated without a door.
Consult your dealer to select the correct door
model.
Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
Install the fireplace only as described in these
instructions.
WARNINGS
TM

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products Cambria

  • Page 1: Operation Instructions

    Lennox Hearth Products wood-burning fireplaces are designed for use as a supplemental heater. They are not intended for continuous use as a primary heat source.
  • Page 2: Safety Rules

    IMPORTANT! GENERAL SAFETY PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY RULES BEFORE YOUR FIRST FIRE. WARNING The CAMBRIA™ fireplace must be installed with an outside air kit intake, which is included with the fireplace WARNING THE FIREPLACE MUST BE OPER- ATED WITH THE DOORS FULLY OPENED OR DOORS FULLY CLOSED.
  • Page 3: Table Of Contents

    In selecting this Lennox Hearth Products wood-burning appliance you have chosen one of the finest fireplaces available. The Cambria™ fireplace is an efficient heat circulat- ing fireplace that is designed to provide you dependable service as well as warmth and enjoyment for many years to come.
  • Page 4: Combustion Control

    HEAT OUTPUT The Cambria™ fireplace is a mid-efficiency fireplace. In spite of the heat that the Cambria fireplace can deliver, it should not replace the main source of heat in your home. This fireplace...
  • Page 5: Refueling For Best Performance

    WARNING: The Cambria™ fireplace was de- signed to allow a spectacular view of the fire. The Cambria fireplace should never be filled in excess (five big logs or more). Excessive fire could damage the fireplace’s hearth and refractory brick and void the warranty.
  • Page 6: Important Cautions

    F. Use only untreated wood. Wood protectors, metallic paper, coal, plastic, waste, sulphur and/or oil will damage the fireplace. G. Do not use the CAMBRIA as an incinerator to burn paper, cardboard or construction material such as pressed wood, plywood or lumber.
  • Page 7: Door Adjustment

    Bearing Maintenance The doors are assembled on retractable slid- ers using roller bearings for easy movement. Cambria fireplace has been designed to ensure that bearing maintenance is easy. Remove the decorative facing by unscrewing the four decorative caps and the four screws holding the facing.
  • Page 8: Glass Care

    Adjustment Screw Figure 11 GLASS CARE Glass Replacement The glass used for the Cambria™ fireplace is a high temperature ceramic glass (1400°F). If the glass breaks or cracks, it must be replaced with an identical ceramic glass. Tempered glass or ordinary glass will not withstand the high temperatures of the Cambria fireplace.
  • Page 9: Fireplace Installation

    The Cambria™ fireplace may be installed directly on the floor or on a raised base but a minimum of 7 feet 6 inches (2.3 m) measured from the base of the appliance to the ceiling is required.
  • Page 10: Framing, Facing And Mantel

    Framing, Facing And Mantel The construction of the framing, facing, and mantel must be in accordance with the stan- dards and the following illustrations (Figures 15 through 20): A. Frame the fireplace using 2” x 3” or heavier lumber. B. WARNING: Combustible materials can- not be used in the space directly above the fireplace, except for the studs above the facade that support the facing and...
  • Page 11: Framing Dimensions

    Framing Dimensions - Model Cambria™ CORNER INSTALLATION 32-7/8” (835mm) 27-7/8” PARALLEL / CHASE INSTALLATION Back Wall of Chase/Enclosure OUTSIDE CHASE Including Finising Materials if any * Zero Clearance From Back Spacer to Wall Rough Framing Face (Unfinished Shown) FRAMING DIMENSIONS Fireplace Opening Width 48-3/4’’...
  • Page 12: Insulated Chase Construction

    Insulated Chase Construction Attic Radiation Shield Note: Floor and wall below the attic must be insulated using the same insulation. 7’ 6” (2.3 m) Min. 7’ 10” (2.4 m) Min. 1/2” Plywood Figure 16 Storm Collar Roof Support Flashing Firestop Drywall or Any Rigid Material 2”...
  • Page 13: Mantel And Facing

    FACING IMPORTANT The facade must be removable once installed. The facade is designed to overlap any facing material installed on the front of the fireplace. If thicker material is installed, use the facade as a template and make sure it can be easily removed for servicing.
  • Page 14: Hot Air Ducting Installation

    Minimum height* 68” (1727 mm) Maximum length - See Figure 22 * The height of the louver must be measured from the base of the Cambria fireplace to the middle point of the louver. WARNING: Both pipe of the double hot air outlet must be installed.
  • Page 15 Central Forced Air Kit The knock-outs provided on the back and on the sides of the Cambria fireplace allow the con- nection of insulated flexible pipe which enables you to heat adjacent rooms up to 50 feet from the fireplace hot air outlet.
  • Page 16: Outside Air Kit

    OUTSIDE AIR It is mandatory to install an outside air connec- tion to the Cambria™ fireplace. The following components are required and are included with the fireplace: • Outside air kit • 4” adapter for fireplace connection The outside air assembly must be installed ac- cording to the following requirements: A) Duct length should be kept to a minimum.
  • Page 17: Chimney System

    2. The Lennox Hearth Products fireplace model Cambria™ fireplace is listed only with Se- curity Chimneys International Ltd 10” dia. chimney systems model Secure Temp ASHT+ / Nova Temp or AC.
  • Page 18 From below, install a firestop in each ceiling/ floor separation through which the chimney will pass. At the attic level, install an attic radiation shield from above (see Figures 30a and 30b). 2. For Secure Temp / Nova Temp ASHT+ chimneys, place the first chimney length on the fireplace.
  • Page 19 OFFSET CHIMNEY INSTALLATION After reaching the location requiring the elbow, proceed as follows. The minimum chimney height when using elbows is: Minimum Chimney Height When Using Elbows Fireplace Model Cambria™ Chimney Model Secure Temp / Nova ASHT+ Temp / AC...
  • Page 20: Offset Chimney Installation

    Chimney Elbow Offset & Height 8” 3” (76mm) (108mm) 15º 16-1/2” (419mm) (514mm) ASHT+ 7-1/2” HT6103+ (191mm) (241mm) 30º 10” 20-3/4” (527mm) (641mm) 10-1/2” 45º (267mm) (343mm) anada 18-1/2” Only (470mm) (540mm) Chimney Elbow Offset & Height ---- 4-1/4” ---- (108 mm) 15º...
  • Page 21 Figure 35 OFFSET CHIMNEY INSTALLATION WITH WALL PENETRATION Figure 36 IF THE CEILING IS 9 FEET OR LESS THIS INSTALLATION CAN ONLY BE ACHIEVED USING 45° ELBOWS. SINCE ONLY 30° ELBOWS ARE ALLOWED. IN THE U.S. THE OFFSET MUST BE DONE ABOVE THE CEILING. OFFSET CHIMNEY INSTALLATION Support Straps...
  • Page 22: Angled Wall Radiation Shield

    ANGLED WALL RADIATION SHIELD (RSMI30, RSMI45, AC10RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required. Note: 45º angle for Canada only In cold climate locations, we recommend that you use the insulated wall radiation shield since it will maintain the home’s thermal barrier.
  • Page 23: Installation Accessories

    Backdraft damper, BISBD Fireplace Blower Kit Two blower kit with thermostatic control, UZY5 Fireplace Model Cambria™ - Approved Venting Components manu- factured by Security Chimneys International only. • 10” diameter chimney - AC (air cooled), Secure Temp™ ASHT+ (or Nova Temp™...
  • Page 24 CHIMNEY - PARTS AND COMPONENTS LISTS Secure Temp ASHT+ 1” High Temp. Insulated Stainless Steel Chimney 10” I.D., Double-Wall Stainless Steel, Listed to CAN/UCL-S604 & UL-103HT Description Lengths and Misc. Chimney Components 8” length, 10” Dia., 10L8-N 12” length, 10” Dia., 10L12-N 18”...
  • Page 25: Replacement Parts

    REPLACEMENT PARTS LIST Cambria™ - Replacement Parts Description Front Edge Refractory Brick Back Refractory Brick Right Side Refractory Brick Left Side Refractory Brick Bottom Refractory Brick Wooden Door Handle Decorative Screw Caps (2) Ceramic Glass (1) Andiron (2) Black Metallic Paint “Forrest Paint” Can Door Gasket: 58-3/4”...
  • Page 26: Product Reference Information

    Your Dealer's Name _________________________________________________ Your Dealer's Phone Number __________________________________________ Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.

Table of Contents