Vent system
requirements
Vented (non-recirculating) system
must terminate to the outside.
Do not terminate the vent system
in an attic or other enclosed area.
Do not use 4" (10.2 cm) laundry-
type wall caps.
Use metal vent only. Rigid metal
vent is recommended. Do not use
plastic or metal foil vent.
• The size of the vent should be
uniform.
• Use no more than three 90°
elbows.
• Make sure there is a minimum
of 24" (61 cm) of straight vent
between the elbows if more
than one elbow is used.
• Do Not install two elbows
together.
• The length of vent system and
number of elbows should be
kept to a minimum to provide
efficient performance.
• The vent system must have a
damper. If roof or wall cap has
a damper, Do Not use damper
supplied with the range hood.
• Use duct tape to seal all joints
in the vent system.
• Use caulking to seal exterior
wall or roof opening around the
cap.
Determine which venting method
is best for your installation and
follow installation steps.
Venting methods
Vent system needed for
installation is not included. 3-1/4"
10" (8.3 cm x 25 cm) rectangular is
recommended.
3-1/4" x 10"
(8.3 cm x 25 cm)
vent through
the roof
Roof venting
4
3-1/4" x 10"
(8.3 cm x 25 cm)
vent through
the wall
Wall venting
Recommended vent system
length
Use 3 1/4" x 10" (8.3 cm x 25 cm)
vent with maximum length of
26 feet (8 m) for vent system. For
best performance, use no more
than three 90° elbows. To calculate
the length of system you need,
add the equivalent feet (meters)
for each vent piece used in the
system. See the following
example.
3-1/4" x 10" (8.3 cm x 25 cm)
vent system
3-1/4" x 10"
(8.3 cm x 25 cm)
90° elbow
6 ft. (1.8 m)
3 ft.
x
(0.93 m)
Maximum length
1 — 90° elbow
9 ft. (2.8 m) straight
1 — wall cap
Length of 3-1/4" x 10"
(8.3 cm x 25 cm)
system
Recommended standard
fittings
3-1/4" x 10"
(8.3 cm x 25 cm)
90° elbow
= 5 ft. (1.5 m)
wall
cap
3-1/4" x 10"
(8.3 cm x 25 cm)
flat elbow
= 12 ft. (3.7 m)
3-1/4" x 10"
(8.3 cm x 25 cm)
wall cap
= 0 ft. (0 m)
Non-vented (recirculating)
vent through the soffit
3-1/4" x 10"
(8.3 cm x 25 cm)
vent
This vent hood is factory set for
venting through the roof or wall.
For non-vented (recirculating)
installations, Non-Vent Kit part no.
wall
883140 is available from your
cap
dealer or authorized parts
distributor.
= 26 ft.
(8 m)
= 5 ft. (1.5 m)
= 9 ft. (2.8 m)
= 0 ft.
(0 m)
= 14 ft. (4.3 m)
3-1/4" x 10"
(8.3 cm x 25 cm)
elbow
vent cover
soffit
damper installation
not required