Overview
The Ultra RX - Extreme Range Receiver has a
10-24Vac/Vdc operation. The Receiver has 4
Channels, 2 Transistors and 2 Relays. The Receiver
can control up to 4 devices.
Carton Inventory
Setup
NOTE: Do not connect power until instructed to do so.

Power Connections

10-24 Vac
NOTE: Polarity does not matter.
1
2
3
4
5
10-24 Vdc
+
-
1
2
3
4
5

Relay Outputs

The Receiver has 2 Relays and 2 Transistor (Open
Collector) Outputs to control up to 4 devices.
Higher Amperage (10 amp) applications that are
directly controlled, should use Relay Channels 1
and 2.
Relay 1:
11: Common
12: Ch 1 Normal Open
13: Ch 1 Normal Closed
Receiver
6
7
8
9
10
11
12
13
6
7
8
9
10
11
12
13
1
2
3
4
5
6
7
8
9
10 11 12 13
Ultra RX - Extreme Range Receiver
Relay 2:
8: Common
9: Ch 2 Normal Open
10: Ch 2 Normal Closed
Lower Amperage (500 ma or lower) applications that
are indirectly controlled, should use Transistor Output
Channels 3 and 4.
Channel 3:
Terminal 5
Channel 4:
Terminal 4
NOTE: To verify, apply a resistance load of 200 ohms
between positive power (1) and terminal 6 or 4.
Measure voltage between negative power (3) and
terminal 6 or 4. When transmitter signal is received,
the transistor should clamp the voltage down.
Dipswitch Settings
NOTE: The Dipswitches on the
Receiver can be accessed by
removing the screw on the
bottom of the Receiver.
Default Dipswitch configuration.
1
Model ULTRX900R
1
2
3
4
5
6
7
8
9
10 11 12 13
1
2
3
4
5
6
7
8
9
10 11 12 13
1
2
3
4
5
6
7
8
9
10 11 12 13

Advertisement

loading

Summary of Contents for Chamberlain Liftmaster ULTRX900R

  • Page 1: Power Connections

    Model ULTRX900R Ultra RX - Extreme Range Receiver Overview Relay 2: 8: Common The Ultra RX - Extreme Range Receiver has a 10 11 12 13 9: Ch 2 Normal Open 10-24Vac/Vdc operation. The Receiver has 4 10: Ch 2 Normal Closed Channels, 2 Transistors and 2 Relays.
  • Page 2 Output Timing Program Channel 1: NOTE: If the Receiver will be programmed as a GCU to a Primary Device proceed to "Alternate: Program Dipswitch Dipswitch Time as GCU" section. The following steps apply only if the Receiver will be used by itself. 0.5 Sec 5 Sec Step 1: Ensure the Receiver does not have power...
  • Page 3 Program Accessories Door Strike or Magnetic Lock Step 1: Connect relays (as shown in Setup: Relay Single Pushbutton Control (WPB1LM) Outputs and the charts below). NOTE: If a Door Strike is used, a separate power supply is required. If a Magnetic Lock is used, use the Normally Closed connections (see below).
  • Page 4 FOR TECHNICAL SUPPORT DIAL OUR TOLL FREE NUMBER: 1-800-528-2806 www.liftmaster.com NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.