Installation; Dear Installer; Safety Requirements And Regulations; Provision Of Ventilation - Rangemaster Elite SE 110 Dual Fuel User's Manual & Installation Instructions

Table of Contents

Advertisement

Check the appliance is electrically safe and gas sound when you have finished.

7. Installation

Dear Installer

Before you start your installation, please complete the details
below, so that, if your customer has a problem relating to
your installation, they will be able to contact you easily.
Installer's Name
Installer's Company
ArtNo.050-0011 - Installer information table
Installer's Telephone Number
Appliance Serial Number

Safety Requirements and Regulations

This cooker must be installed in accordance with
n
n
the relevant instructions in this booklet, with the
relevant national and local regulations, and with
the local gas and electricity supply companies'
requirements.
This cooker is a Class 2 Subclass 1 appliance.
n
n
Before installation, make sure that the cooker is
n
n
suitable for your gas type and supply voltage. See
the data badge.
The appliance must be installed in accordance with
n
n
the regulations in force and only in a well ventilated
space.
Read the instructions before installing or using this
n
n
appliance.
In your own interest and that of safety, it is law
n
n
that all gas appliances be installed by competent
persons. Failure to install the appliance correctly
could invalidate any warranty or liability claims and
lead to prosecution.
This appliance can be converted for use on another
n
n
gas.
INSTALLATION
In the UK the cooker must be installed in
accordance with:
All relevant British Standards / Codes of Practice, in
particular BS 5440 Part 2.
For Natural Gas – BS 6172 and BS 6891.
For LP Gas – BS 5482-1 (when the installation is
in a permanent dwelling), BS 5482-2 (when the
installation is in a caravan or other non- permanent
dwelling), or BS 5482-3 (when the installation is in a
boat).
The Gas Safety (Installation and Use) regulations.
The relevant Building / IEE regulations.
In the Republic of Ireland the cooker must be
installed in accordance with:
The installation must be carried out by a competent person
and installed in accordance with the current edition of IS 813
"Domestic Gas Installations", the current Building Regulations
and reference should be made to the current ETCI rules for
electrical installation.

Provision of Ventilation

This appliance is not connected to a combustion products
evacuation device. Particular attention shall be given to the
relevant requirements regarding ventilation.
All rooms require a window that can be opened, or
equivalent, while some rooms require a permanent vent in
addition to the window.
In the UK:
The room containing the cooker should have an air supply
in accordance with BS 5440 Part 2. All rooms require an
openable window or equivalent, while some rooms require
a permanent vent in addition to the openable window. The
cooker should not be installed in a bedsitting room with
volume less than 20 m³. If it is installed in a room of volume
less than 5 m³ an air vent of effective area 100 cm² is required;
if it is installed in a room of volume between 5 m³ and 10 m³,
an air vent of effective area 50 cm² is required; while if the
volume exceeds 11 m³, no air vent is required.
If there are other fuel burning appliances in the same room,
BS 5440 Part 2 should be consulted to determine the requisite
air vent requirements.
In the Republic of Ireland:
Reference should be made to the current edition of IS 813,
which makes clear the conditions that must be met to
demonstrate that sufficient ventilation is available.
20

Advertisement

Table of Contents