• replacement of broken or missing items • to review repair parts list • to order replacement parts and accessories • to locate the nearest sanitaire warranty station *En Mexico llame al 5670-6169 www.sanitairevac.com PLEASE RETAIN We suggest you record the model, type, and serial numbers below.
Please safeguard the original receipt / invoice. If you experience any problems with your unit during the warranty period, the original receipt / invoice will act as proof of purchase. Contact Sanitaire for any warranty inquiries. Do not return a failed unit to the place of purchase or service center. Any charges for the shipping of a Sanitaire unit under warranty are purchaser’s responsibility unless Sanitaire requests such return in writing.
Use this unit only as described in this manual. Use only manufacturer’s recommended attachments. To reduce the risk of personal injury or damage to your unit use only Sanitaire recommended accessories When using an electrical appliance, basic precautions should always be followed including the...
EXTENSION CORDS When using an extension cord with your unit, refer to the following table to determine the required A.W.G. wire size. Before using the cleaner make sure the power cord and extension cord are in good working condition. Make repairs or replacements before using the unit. Only use extension cords that are rated for outdoor use.
Page 5
7. Turn vacuum switch to the “on” position to 4. Assemble the wand by sliding the top por- begin cleaning. (Fig 6) tion into the lower portion. (Fig 3) Fig 3 5. Attach the hose system to the unit and to your carpet wand.
Page 6
MAINTENANCE GUIDE 6. When the unit is not in use, leave the vacuum To receive reliable service from this equipment, tank lid open. (Fig 11) regular daily maintenance is required. 1. Keep the equipment clean, both inside and out. Lubricate brass quick disconnects with a quality lubricant.
STORAGE OF EQUIPMENT 1. Store extractor indoors in dry area. 2. Recovery and solution tank should be empty and clean when the extractor is not in use. 3. Leave the recovery lid and dump valve open to air out the recovery tank. 4.
Page 8
LOW VACUUM AT THE MACHINE CAUSE: SOLUTION: 1) Drain hose open 1) Close drain hose 2) Lint screen clogged 2) Clean 3) Damaged recovery tank 3) Replace 4) Clogged vacuum motor exhaust port 4) Clean MOTOR RUNNING AND NO VACUUM CAUSE: SOLUTION: 1) Faulty vacuum motor...
Page 9
LOW PUMP PRESSURE CAUSE: SOLUTION: 1) Clogged strained in solution tank 1) Clean and replace. 2) Punctured pump diaphram 2) Replace. 3) Defective rectifier or motor 3) Replace. PUMP PRESSURE VARIES CAUSE: SOLUTION: 1) Defective pump. 1) Replace pressure control switch.