Tyler Advantage N6DHPLLR Installation & Service Manual

Advantage series high performance multi-shelf merchandiser medium temperature self serve display cases

Advertisement

Installation & Service
N6DHPL(LR), N6DHPM(MR), N6DHPH
HIGH PERFORMANCE MULTI-SHELF MERCHANDISER
Medium Temperature Self Serve Display Cases
This manual has been designed to be used in conjunction with the
General (UL/NSF) Installation & Service Manual.
Save the Instructions in Both Manuals for Future Reference!!
This merchandiser conforms to the American National Standard Institute & NSF International Health and Sanitation standard ANSI/NSF 7 - 2003.
PRINTED IN Specifications subject to REPLACES
IN U.S.A.
change without notice.
Manual
ISSUE
8/05
EDITION
DATE
Tyler Refrigeration * Niles, Michigan 49120
PART
12/05
9037176
NO.
D
REV.

Advertisement

Table of Contents
loading

Summary of Contents for Tyler Advantage N6DHPLLR

  • Page 1 This merchandiser conforms to the American National Standard Institute & NSF International Health and Sanitation standard ANSI/NSF 7 - 2003. PRINTED IN Specifications subject to REPLACES ISSUE PART 8/05 12/05 9037176 IN U.S.A. change without notice. EDITION DATE REV. Tyler Refrigeration * Niles, Michigan 49120...
  • Page 2: Table Of Contents

    N6DHP(L, M, H, LR, MR) Tyler Refrigeration CONTENTS Page Specifications N6DHPL / N6DHPM / N6DHPH / N6DHPLR / N6DHPMR Specification Sheets ........4 Pre-installation Responsibilities .
  • Page 3 Operational Parts List ........20 TYLER Warranty ....(See General-UL/NSF I&S Manual)
  • Page 4 N6DHP(L, M, H, LR, MR) Tyler Refrigeration SPECIFICATIONS N6DHP(L, M, H, LR, MR) High Performance Med. Temp. Merchandisers Page 4 September, 2005...
  • Page 5 Installation & Service Manual N6DHP(L, M, H, LR, MR) August, 2005 Page 5...
  • Page 6 N6DHP(L, M, H, LR, MR) Tyler Refrigeration Page 6 August, 2005...
  • Page 7: Installation Procedures

    Case Pull-Up Locations For U.L. and temperature performance requirements, N6DHPLR and N6DHPMR cases must be backed by a refrigerated area. TYLER walk-in coolers are available with the necessary special parts and instructions to make the installation. NOTE Please ensure that the cooler opening is insulated and sealed completely to the rear of the display case.
  • Page 8: Refrigeration Procedures

    Setpoint” position. will stop. 5. Set the keypad Locked/Unlocked jumper The settings above are specific to TYLER blocks to the “Unlocked” position. N6DHP cases. Other applications will require 6. Replace the electronic thermostat cover different setpoints and differentials.
  • Page 9: Electrical Procedures

    Installation & Service Manual N6DHP(L, M, H, LR, MR) Electrical Procedures Defrost Information Electrical Considerations See “General-UL/NSF I&S Manual” for operational descriptions for each type of CAUTION defrost control. Make sure all electrical connections at Defrost Control Chart components and terminal blocks are tight. Defrost This will prevent burning of electrical Defrost...
  • Page 10: N6Dhp(L/M/H/Lr/Mr) Domestic & Export (50Hz) Case Circuits

    N6DHPL Dom. & Exp. (50Hz) Case Circuits (4’ Cases) Page 10 January, 2006...
  • Page 11 N6DHP(L, M, H, LR, MR) Dom. & Exp. (50Hz) Case Circuits (6’ & 8’ Cases) November, 2006 Page 11...
  • Page 12 N6DHP(L, M, H, LR, MR) Dom. & Exp. (50Hz) Case Circuits (12’ Cases) Page 12 November, 2006...
  • Page 13: Cleaning And Sanitation

    Installation & Service Manual N6DHP(L, M, H, LR, MR) CLEANING AND SANITATION 3. Remove mounting screws from rear duct panel. Component Removal and 4. Slowly lift out rear duct panel until the shelf Installation Instructions for harness connector near the top of the panel can be accessed.
  • Page 14: Front Cladding

    N6DHP(L, M, H, LR, MR) Tyler Refrigeration Front Cladding Egg Merchandiser Kit Instruction 1. Remove front kickplate and raceway cover. (See General-UL/NSF I&S Manual.) 2. Remove color band, bumper and bumper retainer from the case. (See General- UL/NSF I&S Manual.) 3.
  • Page 15: Peg Bar Information

    Installation & Service Manual N6DHP(L, M, H, LR, MR) Peg Bar Information (All Models) The hang up blister pack has become a standard means of marketing sliced luncheon meats and other delicacies. It appears that all that is needed to adapt multi-shelf cases for these packages is to add peg bars and pegs.
  • Page 16: Peg Bar Information For Cannon Magna Peg Bar Display

    Air baffles are available from TYLER that are compatible with 15” offset support arms. 3. Non-load bearing air baffle should run the same width as the peg bar.
  • Page 17: Rear Load Air Close-Off Information (N6Dhplr/N6Dhpmr)

    Installation & Service Manual N6DHP(L, M, H, LR, MR) TYLER 8 and 12 foot cases have four foot sections for merchandising. 6 foot cases have three foot sections for merchandising. Further guidelines for section to section mer- chandising are listed below:...
  • Page 18: Parts Information

    N6DHP(L, M, H, LR, MR) Tyler Refrigeration PARTS INFORMATION Cladding and Trim Parts List Item Description 4’ 6’ 8’ 12’ Screw 5183536 (4) 5183536 (4) 5183536 (6) 5183536 (8) Screw 5183536 (8) 5183536 (8) 5183536 (8) 5183536 (8) End Cover...
  • Page 19 Installation & Service Manual N6DHP(L, M, H, LR, MR) Item Description 4’ 6’ 8’ 12’ Horizontal End Trim (N6DHP) 5211585 5211585 5211585 5211585 (N6DHPR) ----- ----- 5211585 5211585 Pop Rivet 5105037 (5) 5105037 (5) 5105037 (10) 5105037 (14) N6DHPM ILLUSTRATED August, 2005 Page 19...
  • Page 20: Operational Parts List

    5614628 5614628 5614628 5614628 (stationary) 5614629 5614629 5614629 5614629 Light Switch 5100565 5100565 5100565 5100565 NSF Product Thermometer 5967100 5967100 5967100 5967100 For information on operational parts not listed above contact the TYLER Service Parts Department. Page 20 December, 2005...

Table of Contents