Program Scan; Setting Scan Limits - Kenwood TM-D700 E Instruction Manual

144/440 mhz fm dual bander 144/430 mhz fm dual bander
Table of Contents

Advertisement

PROGRAM SCAN

Program Scan is identical with VFO Scan except that
you select the frequency range of the scan.
1 s
9

Setting Scan Limits

You can store up to 10 scan ranges in memory
channels L0/U0 to L9/U9.
1 Select the desired band.
2 Press [VFO].
3 Select the desired frequency as the lower limit.
4 Press [F].
• A memory channel number appears and blinks.
5 Turn the Tuning control, or press Mic [UP]/
[DWN], to select a channel in the range L0 to L9.
52
6 Press [M.IN].
• The lower limit is stored in the channel.
7 Select the desired frequency as the upper limit.
8 Press [F].
9 Turn the Tuning control, or press Mic [UP]/
[DWN], to select a matching channel in the range
U0 to U9.
• If you have selected for example L3 in step 5, select
U3.
10 Press [M.IN].
• The upper limit is stored in the channel.
To confirm the stored scan limits, press [MR], then
select the L and U channels.
Note:
The lower limit must be lower in frequency than the upper limit.
The lower and upper frequency step sizes must be equal.
The lower and upper limits must be selected on the same band.