- STEP 3: INSTALL FAUCET (cont.)-
B. ASSEMBLE
FAUCET
ULTRAFILTER
150
1. Loosely
assemble
the base,
spacer,
washer
and
plastic
nut onto the faucet
stud.
2. Route
the 1/4"
red tubing
through
the
sink
or
countertop
hole and connect
to 1/4"
barb on faucet.
3. Route
the 3/8"
black
tubing
through
sink or the
countertop
hole and connect
to 3/8"
barb on faucet.
4. Attach
the 3/8"
blue
tubing
to the faucet
stud us-
ing the tubing
adaptor.
5. Lower
faucet
into place on the countertop,
on the
underside
of the countertop
or sink slide the slotted
washer
into place
and
tighten
plastic
nut.
Tighten
the nut so the faucet
cannot
move,
but do not over-
tighten.
UltraFilter
150
faucet & spout
H
hole in sink or
b__i_
bers
slotted washer _
(_
""
washer -......._ ( _
hex nut _
(_
1/4" red tubing
from RO drain
(connect to 1/4"
barb on faucet)
3/8" blue tubing
(connect to stud
on faucet)
tubing adaptor
(connects to
/bottom
of stud)
3/8" black tubing
to
drain point (connect
to 3/8" barb on faucet)
/
Figure 6
7