OIL-FIRED WATER BOILERS/NO. 2 OIL

INSTALLATION AND OPERATING INSTRUCTIONS

SAFETY WARNING:
KEEP BOILER AREA CLEAR AND FREE FROM COM-
BUSTIBLE MATERIALS, GASOLINE AND OTHER FLAM-
MABLE VAPORS AND LIQUIDS. FAILURE TO ADHERE TO
ABOVE SAFETY WARNING, MAY RESULT IN PERSONAL
INJURY OR DEATH AND PROPERTY DAMAGE.
CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PAGE
Ratings and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation Requirements:
Boiler Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 & 4
Chimney Requirements . . . . . . . . . . . . . . . . . . . . . . . . . .3
Baffle Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Air Supply and Venting . . . . . . . . . . . . . . . . . . . . . . . . .3-7
Controls and Accessories . . . . . . . . . . . . . . . . . . . . . . . . .7
Piping for Water Units . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Installing Burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Oil Supply Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Wiring the Boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Vent Piping and Draft Regulator . . . . . . . . . . . . . . . . . . . .8
Operating Instructions:
Precautions Before Starting . . . . . . . . . . . . . . . . . . . . . . .8
Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Cleaning and Filling New Water Boiler . . . . . . . . . . . . . . .8
Extended Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Freezing Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Oil Burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
General Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-16
Burner Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17-21
SERVICE COMPANY
Name ______________________________
Address_____________________________
___________________________________
Telephone ___________________________
Model #_____________________________
Serial # _____________________________
E -10
IMPORTANT: The installation of this equipment must con-
form to the requirements of the authority having jurisdiction
or, in the absence of such requirements, to the Installation of
Oil Burning Equipment, ANSI/NFPA 31, latest edition, and to
the National Electrical Code ANSI/NFPA 70, latest edition.
The installation must also conform to the additional require-
ments in this Slant/Fin Instruction Manual. Where there is any
difference, the more stringent requirement shall govern.
In addition, where required by the authority having jurisdiction,
the installation must conform to American Society of Mechanical
Engineers Safety Code for Controls and Safety Devices for
Automatically Fired Boilers, No. CSD-1, latest edition.
THIS MANUAL MUST BE LEFT WITH OWNER AND
SHOULD BE HUNG ON OR ADJACENT TO THE BOILER
FOR REFERENCE.
IMPORTANT: This boiler must be installed, serviced and
repaired by a trained, experienced, service technician,
licensed for the installation and servicing of oil burning hot
water heating system equipment or otherwise qualified by the
authorities having jurisdiction over the installation.
Printed in U.S.A. 113
Part No. 470900000
Publication No. EC-10-40 Rev.A

Advertisement

Table of Contents
loading

Summary of Contents for Slant/Fin EUTECTIC EC-16-1.25

  • Page 1: Table Of Contents

    Extended Shutdown ......9 ments in this Slant/Fin Instruction Manual. Where there is any Freezing Protection .
  • Page 2: Ratings And Dimensions

    1.15 (water). D.O.E. capacity output is NOTE: All boilers under 300,000 Btuh (87.9 kw) input are tested and rated for divided by the allowance to obtain net rating. The Slant/Fin Technical Service capacity under the U.S. Department of Energy (D.O.E.) Test Procedures for department should be consulted before selecting a boiler for unusual piping Boilers.
  • Page 3: Boiler Location

    EUTE TI E -10 THE INSTALLATION INSTRUCTIONS IN THIS MANUAL CHIMNEY REQUIREMENTS (see NFPA 211, latest edition) A. The chimney must be constructed in accordance with all ARE ABBREVIATED. SEE THE FRONT COVER OF THIS local applicable codes and the National Board of Fire MANUAL FOR REFERENCES TO CODES AND STAN- Underwriters.
  • Page 4: Clearances

    EUTE TI E -10 PITCH UP PITCH UP 1/4" PER 1/4" PER LINEAR FOOT LINEAR FOOT DO NOT INSTALL DRAFT REGULATOR HERE DOUBLE SWING BAROMETRIC DRAFT CONTROL INSTALLED ON HORIZONTAL CONNECTOR DO NOT INSTALL DRAFT REGULATOR HERE BAROMETRIC DRAFT CONTROL INSTALLED ON VERTICAL RISE DRILL 1/4"...
  • Page 5 EUTE TI E -10 unreliable, CO and overfire draft* will change unpredictably. the chimney through the vent regulator into the living space. DO NOT operate this boiler and a solid fuel burning appliance DO NOT vent this boiler to the same chimney flue used by a at the same time, unless the solid fuel burner is provided with fireplace or coal or wood burning furnace or boiler.
  • Page 6 EUTE TI E -10 CHIMNEY CHIMNEY 12 IN 12 IN 6 IN. MAX. 6 IN. MAX. Figure 3a. FIGURE 3a. APPLIANCES LOCATED IN CONFINED SPACES. Figure 3b. FIGURE 3b. APPLIANCES LOCATED IN CONFINED SPACES. AIR FROM INSIDE THE BUILDING. AIR FROM OUTDOORS. SEE TABLE 2 (2.4) Appliances located in confined spaces.
  • Page 7: Controls And Accessories

    For Indirect-fired storage water heater application, see installed. Slant/Fin publication WH-10, Sizing Guide WH-SG and II. AIR CONTROL SYSTEMS Installation manual WH-40. The installation manual includes A. DIAPHRAGM-TYPE COMPRESSION TANKS are used...
  • Page 8: Oil Supply Piping

    (and B. The observation port cover is mounted on the hinged burner return if two-pipe) to facilitate servicing. See Slant/Fin publica- mounting door (see figure 2 on page 2). NEVER touch the tion on one-pipe and two-pipe fuel oil systems.
  • Page 9: Care And Maintenance: Extended Shutdown

    EUTE TI E -10 II. Filling and venting the water boiler after cleaning 1. Remove the flue pipe from the boiler flue collar and A. Refill the system with fresh water. clean thoroughly. B. Bring water temperature to at least 180° F promptly. 2.
  • Page 10: Iii. Oil Burner

    Useful information on the characteristics, mixing propor- tions, etc. of glycol in heating systems is given in Technical Topics No. 2A, available from the Slant/Fin website, go to http://slantfin.com. Go to library, select current literature, select boiler model. See related topics and select antifreeze and hydronic systems.
  • Page 11: Wiring Diagrams

    EUTE TI E -10...
  • Page 12 EUTE TI E -10...
  • Page 13 EUTE TI E -10...
  • Page 14 EUTE TI E -10 Honeywell L 7248C –1030 Aquastat Control Multiple Zoned (Circulator or Zone Valve) Single Zone, Heat Wise or Riello Burner...
  • Page 15 EUTE TI E -10 Honeywell L7248L, See “Adjusting Settings” & “error Codes” for Beckett 7600A and L7248L on page 16 HydroLevel 3250 Controls...
  • Page 16 EUTE TI E -10 FOR  L7248L °F or °C. Pressing the I button again (on L7224 models) will display the ADJUSTING SETTINGS Low Limit (LL) followed by a three-digit number and the corresponding To discourage unauthorized changing of Aquastat settings, a procedure degree designator.
  • Page 17: Burner Data

    EUTE TI E -10 BURNER DATA—CARLIN BURNERS FOR PACKAGED BOILERS ONLY Nozzles Firing Head Approx. Shutter Boiler Burner Blast Oil Pump Rate Adjusting Air Band Non- Size Angle & Model Model Tube (PSIG) MFR. Plate † Setting Adjustable Type 0.65 45˚A Delavan .60/.65...
  • Page 18 EUTE TI E -10 BURNER DATA—BECKETT BURNERS FOR PACKAGED BOILERS ONLY Nozzles Firing Approx. Approx. Approx. Boiler Burner Blast Oil Pump Size Angle & Rate Head Air Shutter Air Band Model Model Tube MFR. (PSIG) Type Setting † Setting † Setting 0.65 60˚AS...
  • Page 19 EUTE TI E -10 Check/Adjust “Z” Dimension – L1 & L2 Heads Figure 9. Head Adjustment L1 & L2 Beckett Head 1. See figure above. The important “Z” dimension is the distance from the leading edge of the head to the end of the air tube. This distance for L1 and L2 heads is 1-3/8”...
  • Page 20 EUTE TI E -10 BURNER DATA - RIELLO BURNERS FOR PACKAGED BOILERS ONLY (RIELLO R-40 SERIES W/SHORT TUBE) Nozzles Approx. Approx. Boiler Burner Blast Firing Rate Oil Pump Head Size Angle & Model Model Tube (PSIG) MFR. Setting † Setting † Type 0.65 0.55...
  • Page 21 EUTE TI E -10 BURNER DATA - RIELLO (continued) 1. Regulation of the combustion air flow is made by adjustment of the manual AIR ADJUSTMENT PLATE (4) after loosening REGULATION OF THE TURBULATOR AND AIR SHUTTER FOR the FIXING SCREWS (3&5). The initial setting of the air adjustment plate should be made according to figure 13.
  • Page 22 Notes:...
  • Page 23 Notes:...
  • Page 24 ©Slant/Fin Corp. 2013. SLANT/FIN CORPORATION, Greenvale, N.Y. 11548 • Phone: (516) 484-2600 Canada: Slant/Fin Mississauga, Ontario FAX: (516) 484-5921 • LTD/LTEE, www.slantfin.com...

Table of Contents