Download Print this page
Johnson Controls GG9S Technical Manual

Johnson Controls GG9S Technical Manual

Gg9s series 95.5% single stage gas-fired residential multi-position gas furnaces natural gas 40 - 130 mbh input

Advertisement

Quick Links

TECHNICAL
TECHNICAL
GUIDE
GUIDE
95.5% SINGLE STAGE
GAS-FIRED RESIDENTIAL
MULTI-POSITION GAS FURNACES
MODELS: GG9S
NATURAL GAS
40 - 130 MBH INPUT
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Lifetime limited warranty on both heat exchangers to the orig-
inal purchaser; a 20-year limited warranty from original instal-
lation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli-
cations.
Standard 5-year limited Parts warranty.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and vent piping.
FEATURES
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
Blower-off delay for cooling SEER improvement.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code displays
standard on integrated control module for reliable operation.
Low unit amp requirement for easy replacement application.
Single wire twinning or staging feature available.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
100% shut off main gas valve for extra safety.
4 speed, direct drive PSC motor.
24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Secondary heat exchanger made of corrosion resistant
stainless steel materials.
Timed on, adjustable off blower capability for maximum com-
fort.
Blower door safety switch.
Solid removable bottom panel allows easy conversion.
Airflow leakage less than 1% of nominal airflow at duct-
blaster conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Protection included from air intake, exhaust vent, or conden-
sate blockage.
Venting applications - may be installed as either 2-pipe
(sealed combustion) or single-pipe vent (using indoor com-
bustion air).
No special vent termination required.
1/4 turn knobs provided for easy door removal.
Internal condensate trap design (patent pending) provides
condensate management options, easy visual operation,
and is self-priming to prevent nuisance problems.
400995-UTG-D-0210

Advertisement

loading

Summary of Contents for Johnson Controls GG9S

  • Page 1 GAS-FIRED RESIDENTIAL economical installation and operation. MULTI-POSITION GAS FURNACES These units are Category IV listed and may be vented either MODELS: GG9S through side wall or roof applications using approved plastic combustion air and vent piping. NATURAL GAS 40 - 130 MBH INPUT FEATURES •...
  • Page 2: Left Side

    Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water. Johnson Controls Unitary Products...
  • Page 3: Filter Performance

    S1-1PS3302 - 100, 120, 130 S1-1NP0501 - 130K Model Thermostats - Compatible thermostat controls are available through accessory sourcing. For optimum performance and installation, refer to the UPGNET “Low Voltage Wiring Diagram” document to select and apply controls. Johnson Controls Unitary Products...
  • Page 4 Medium Low 1614 1591 1549 1531 1459 1400 1335 1267 1180 1061 1327 1294 1257 1224 1198 1171 1124 1036 1. Airflow expressed in standard cubic feet per minute (CFM). 2. Motor voltage at 115 V. Johnson Controls Unitary Products...
  • Page 5 1. Airflow expressed in standard cubic feet per minute (CFM). 2. Return air is through side opposite motor (left side). 3. Motor voltage at 115 V. 4. Airflow through across motor side (right side) may be slightly less than the data shown above. Johnson Controls Unitary Products...
  • Page 6 NOTES Subject to change without notice. Published in U.S.A. 400995-UTG-D-0210 Copyright © 2010 by Johnson Controls, Inc. All rights reserved. Supersedes: 400995-UTG-C-0209 Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069...