Download Print this page

Honeywell Lynx Touch L5100 Technical Training Manual

Z-wave setup
Hide thumbs Also See for Lynx Touch L5100:

Advertisement

Quick Links

Lynx Touch – L5100
Technical Training
Z-Wave Setup

Advertisement

loading

Summary of Contents for Honeywell Lynx Touch L5100

  • Page 1 Lynx Touch – L5100 Technical Training Z-Wave Setup...
  • Page 2 40 Devices (Lights, switches and lamp modules) 3 Thermostats 4 Door Locks • Rules and Scenes 20 Rules (Event Based Actions) 20 Schedules (Time Based Actions) 20 Scenes (Pre-defined set of actions) • Remote Control using Total Connect HONEYWELL - CONFIDENTIAL File Number...
  • Page 3 Z-Wave Setup • First, Enable the Z-Wave Module Enable the L5100 for Z-Wave Before Installing the Z-Wave Module. Enter Installer Programming and Touch the Page Down Arrow. • From this Screen, Touch “Z-Wave”. HONEYWELL - CONFIDENTIAL File Number...
  • Page 4 Z-Wave Setup • Next, Touch “Z-Wave” and Toggle it to “Enabled…” • Touch “Temperature Display” to Toggle Celsius, if Needed. • Touch Save After Making Changes HONEYWELL - CONFIDENTIAL File Number...
  • Page 5 Z-Wave Setup • Z-Wave Module is Installed Telephone Side Power System Down Before Installation and after Enabling in Programming HONEYWELL - CONFIDENTIAL File Number...
  • Page 6 Lynx Touch – L5100 Technical Training Including Devices...
  • Page 7 Including Devices • To Include Devices Touch the Automation Icon. • Next Touch “Tools”, and followed by, “Include Devices”. Note: Install Switch and Thermostats in Final Location Before Inclusion. HONEYWELL - CONFIDENTIAL File Number...
  • Page 8 Including Devices • The L5100 will Enter Inclusion Mode and Prompt You When Ready to Include Devices. • Toggle the Device On/Off or Press the Device’s Function Button to Enroll. HONEYWELL - CONFIDENTIAL File Number...
  • Page 9 The L5100 will Include the Device into its Network. • After Included, the Device Type, Manufacture and Node ID will be displayed. • To Include More Devices, Touch “Include.” • When Finished, Touch the Back Arrow. HONEYWELL - CONFIDENTIAL File Number...
  • Page 10 • Make Sure the Switch/Module Indicator LED is Illuminated • Press, and Release, the Switch/Module Button to Include. • The Indicator LED will Flash Amber During the Inclusion Process ON/OFF Enroll Button ON/OFF Enroll Button HONEYWELL - CONFIDENTIAL File Number...
  • Page 11 Including Devices Including a Yale Lock • Activate the Yale Touch Screen by Palming the Keypad with Your Hand • Next, Follow the Steps below, Starting with the Master PIN • Default Master PIN is “12345678” HONEYWELL - CONFIDENTIAL File Number...
  • Page 12 Including Devices Including a Kwikset Lock • Remove the Back Cover, then Press and Release the “A” Button HONEYWELL - CONFIDENTIAL File Number...
  • Page 13 Including Devices Enrolling Schlage Locks HONEYWELL - CONFIDENTIAL File Number...
  • Page 14 Including Devices Enrolling a Schlage Lock • The program code can be found on top of document number 1 of the LiNK Installation Instructions. • It can also be found on the back of the lock HONEYWELL - CONFIDENTIAL File Number...
  • Page 15 Lynx Touch Can Push User Codes to Z-Wave Locks • Unlocking Door with Code Can Unlock or Also Disarm Note: During Inclusion, Each Programmed User Code Will Take 4 Seconds to Transfer to the Z-Wave Lock. HONEYWELL - CONFIDENTIAL File Number...
  • Page 16 Including Devices Including a ZWSTAT • At the ZWSTAT, Enter the Program Mode Press SYSTEM Press, and Hold the 3rd and 5th Buttons Simultaneously HONEYWELL - CONFIDENTIAL File Number...
  • Page 17 Including Devices Including a ZWSTAT • Press the Down Arrow Until the Following Screen is Displayed: HONEYWELL - CONFIDENTIAL File Number...
  • Page 18 Including Devices Including A Thermostat • Press the Up Arrow to Change the Option to a “1” Change This Value to a “1” This Will Be Displayed • Press DONE on the ZWSTAT to Exit Programming HONEYWELL - CONFIDENTIAL File Number...
  • Page 19 Including Devices • Each Device May be Renamed by Selecting the Device, Found within its Category. HONEYWELL - CONFIDENTIAL File Number...
  • Page 20 Including Devices • Touch “Edit” to Edit the Name. • Use the Keyboard to Enter a New Name for this Lock. • Touch “Done” when Complete HONEYWELL - CONFIDENTIAL File Number...
  • Page 21 The New Name will Appear on the Device Control Screen and on the Selection List. • Touch “Back” to Return to the Selection List. • To Return to the Automation Screen, Touch the Back Arrow “”. HONEYWELL - CONFIDENTIAL File Number...
  • Page 22 Including Devices • Each Selection List Has a Refresh Status Button • Refresh Status will Poll Each Device for its Current Status. Supports real time status HONEYWELL - CONFIDENTIAL File Number...
  • Page 23 Locks – Low Power at 6 Feet Max Range  Does not apply to the latest firmware of the Yale locks • Include Z-Wave Locks First, at the L5100. = Low Power Inclusion Direct Range Device HONEYWELL - CONFIDENTIAL File Number...
  • Page 24 Include All Switches and Thermostats Using Program Tool. If Using the USB Program Tool, Save Device Map When Complete. • Shift L5100 to Secondary Controller. (Advanced Tools) • Enroll L5100 into Program Tool as Secondary Controller. • L5100 Imports Z-Wave Device Map. HONEYWELL - CONFIDENTIAL File Number...
  • Page 25 Transfer Primary Control from Program Tool Shifts Primary Control to L5100 • L5100 Queries All Devices For Node Information and Updates Node Map (Network Rediscovery) • Take L5100 to Z-Wave Locks to Enroll Can be Accomplished Running on Battery Only HONEYWELL - CONFIDENTIAL File Number...
  • Page 26 Including Devices • Locks Must be Included Directly Into the L5100 Secure Devices (Locks) Are Not Support by Remotes Low Power Inclusion Range HONEYWELL - CONFIDENTIAL File Number...
  • Page 27 Lynx Touch – L5100 Technical Training Excluding Devices...
  • Page 28 Devices Removed Without Being Excluded will Still Need to Undergo the Exclusion Process. 15 second supervision rate • Devices that Fail Inclusion Should be Excluded before Re- Attempting to be Included. • See Advanced tools for more information HONEYWELL - CONFIDENTIAL File Number...
  • Page 29 Excluding Devices • To Exclude a Device, Touch “Tools” and “Exclude Devices” from the Automation Screen. • After Entering Exclusion Mode, the L5100 will Prompt You to Press the Function Button on the Device. HONEYWELL - CONFIDENTIAL File Number...
  • Page 30 Excluding Devices • Results Shown When Devices Are Excluded • If the Excluded Device was Not Part its Own Network, “Unknown Device Excluded” will be Displayed. • To Exclude Additional Devices, Touch “Exclude”. HONEYWELL - CONFIDENTIAL File Number...
  • Page 31 Lynx Touch – L5100 Technical Training Advanced Tools...
  • Page 32 Advanced Tools • Node/Device Supervision Provides Notice of Failed Nodes • Network Rediscovery HONEYWELL - CONFIDENTIAL File Number...
  • Page 33 Advanced Tools • Failed Nodes Listed • Fixing Failed Nodes, Deletes the Device HONEYWELL - CONFIDENTIAL File Number...
  • Page 34 The L5100 has a Suite of Advanced Z-Wave Tools • View Enrolled Devices • View Enrolled Controllers • Reset Controller • Pri. Controller Shift to Secondary • Learn • Locking Door • Base Command Set On • Base Command Set Off HONEYWELL - CONFIDENTIAL File Number...
  • Page 35 Advanced Tools • To Access the Advanced Tools Menu: From the Automation Screen, “Touch Tools” From the Tools Screen, Touch “Advanced Tools” HONEYWELL - CONFIDENTIAL File Number...
  • Page 36 Advanced Tools • To Access the Advanced Tools Menu: Next, Enter the System Master Code HONEYWELL - CONFIDENTIAL File Number...
  • Page 37 Advanced Tools • View Enrolled Devices – Lists All Mapped Slave Nodes System Index/Name Device Type Device ID Node Number Manufacturer HONEYWELL - CONFIDENTIAL File Number...
  • Page 38 Advanced Tools • View Enrolled Controllers – Lists All Mapped Primary and Secondary Controllers Node Number Controller Role: (P)rimary or (S)econdary Home ID Device Type Device ID Manufacturer HONEYWELL - CONFIDENTIAL File Number...
  • Page 39 Advanced Tools • Reset Controller – Default Resets Controller Deletes All Nodes Generates a New Random Home ID HONEYWELL - CONFIDENTIAL File Number...
  • Page 40 Pri. Controller Shift to Secondary – Transfers the Role of Primary Controller to Another Controller, Usually a Z-Wave Remote Control. Z-Wave Network is Duplicated Both controllers Can Operate the Z-Wave Devices Only the Primary Can Include/Exclude Devices HONEYWELL - CONFIDENTIAL File Number...
  • Page 41 Usually on a Z-Wave Remote Control. Start Include Process on Remote/Primary, then Touch Learn Z-Wave Network is Duplicated Both controllers Can Operate the Z-Wave Devices Only the Primary Can Include/Exclude Devices Z-Wave Remote Used to Include Z-Wave Devices During Setup HONEYWELL - CONFIDENTIAL File Number...
  • Page 42 Advanced Tools • Locking Door – Locking the Door Can Arm the Panel in the Following Modes Arm Away Arm Without Auto Stay Arm Stay HONEYWELL - CONFIDENTIAL File Number...
  • Page 43 Advanced Tools • Base Command Set On – Turns On All Switches. Some Thermostats Enter Energy Savings Mode Locks Ignore this Command Z-Wave Certification Required Test Command HONEYWELL - CONFIDENTIAL File Number...
  • Page 44 Advanced Tools • Base Command Set Off – Turns Off All Switches. Some Thermostats Exit Energy Savings Mode Locks Ignore this Command Z-Wave Certification Required Test Command HONEYWELL - CONFIDENTIAL File Number...
  • Page 45 Z-wave information is uploaded into Compass, so it can be used to recreate the scenes, rules and schedules originally created if necessary. Use a secondary controller, connected to a laptop (such as the Leviton USB device), save the information to a file. HONEYWELL - CONFIDENTIAL File Number...
  • Page 46 Nodes start at 1 (primary controller), and go to 232. If you include and exclude the same device 232 times, you will run out of nodes, and the controller will then restart and fill open nodes HONEYWELL - CONFIDENTIAL File Number...
  • Page 47 No. But, most manufacturers don’t support it yet, including Leviton. • What if I install more than 40 light switches on a L5100? You can add more than 40, you cant control more than 40 HONEYWELL - CONFIDENTIAL File Number...