APC BACK-UPS PRO 1200/1500 Installation And Operation Manual

Apc power supply user manual.
Back-UPS
Installation and Operation
Inventory
Connect the battery
Install PowerChute
®
Pro 1200/1500 230V
®
Personal Edition Software
APC PowerChute Personal Edition software provides automatic file saving and shutdown of
your computer in the event of a power failure. Use the cable supplied with the Back-UPS to
connect the data port on the Back-UPS to the USB port on your computer. Place the CD into
your computer, and follow the on-screen instructions.
Safety
(2)
Do not install the Back-UPS in direct
sunlight, in excessive heat, humidity, or
in contact with fluids.

   Related Manuals for APC BACK-UPS PRO 1200/1500

   Summary of Contents for APC BACK-UPS PRO 1200/1500

  • Page 1

     Install PowerChute APC PowerChute Personal Edition software provides automatic file saving and shutdown of your computer in the event of a power failure. Use the cable supplied with the Back-UPS to connect the data port on the Back-UPS to the USB port on your computer. Place the CD into your computer, and follow the on-screen instructions.

  • Page 2

    Connect the equipment Battery Backup and Surge Protected outlets When the Back-UPS is receiving input power, the Battery Backup with Surge Protection outlets will supply power to connected equipment. During a power outage or other utility problems, the Battery Backup outlets receive power for a limited time from the Back-UPS.

  • Page 3

    Operation Power-Saving Function To conserve electricity, configure the Back-UPS to recognize a Master device, such as a desktop computer or an A/V receiver, and Controlled peripheral devices, such as a printer, speakers, or a scanner. When the Master device goes into Sleep or Standby mode, or is switched OFF, the Controlled device(s) will be switched off as well, saving electricity.

  • Page 4

    Front Panel Buttons and Display Interface Use the three buttons on the front panel of the Back-UPS and the display interface to configure the Back-UPS. Front panel  Mute button  Power On/Off button  Display button  Display interface On Line—The Back-UPS is supplying conditioned utility power to connected equipment Power-Saving—Master and Controlled outlets are enabled, saving power when the master device goes into sleep or standby mode...

  • Page 5

    Back-UPS. If the Overload icon stops flashing, the Back-UPS is no longer overloaded and will continue to operate normally. The Back-UPS is operating on utility power, but the battery is not functioning properly. Contact APC Customer Service to order a replacement battery. See “Replacement Battery” on page 8.

  • Page 6

    Function Button Quick-Reference Function Button Power Power On Power Off Display Status Inquiry Full-Time/Power- Saving mode Mute Event Specific General Status Enable/ Disable Sensitivity Master/Controlled outlet Enable/Disable Master/Enable Threshold Calibration Self-Test (manual) Event Reset Fault Reset Back-UPS Pro 1200 & 1500 230 V Installation and Operation Timing Description (seconds)

  • Page 7

    Determine which internal fault message is displayed by matching the number displayed on the LCD with the corresponding Fault Message (see System Faults) and contact APC Technical Support. Confirm that the correct peripherals are connected to Controlled outlets. If this feature is not desired, disable the Power-Saving Master and Controlled outlets.

  • Page 8

    APC Technical Support representative. APC will ship the replacement unit once the defective unit has been received by the repair department, or cross-ship upon the receipt of a valid credit card number. The customer pays for shipping the unit to APC. APC pays...

Comments to this Manuals

Symbols: 0
Latest comments:
  • Richard lutman Oct 31, 2014 10:19:
    Fault code f06, how to repair it.