ISN-CP1-CM-W50, ISN-CP1-CM-N100 | Installation Instructions | 1.0 Installation Considerations 1.0 Installation Considerations 2.0 Installation The detector senses intruder movement Do not apply power until after you and notifies an alarm control panel. connect and inspect all wires. Because the detector is only one part of a 1.
Page 3
ISN-CP1-CM-W50, ISN-CP1-CM-N100 | Installation Instructions | 2.0 Installation When adding two or more detectors to a Figure 2: PIR Detector Base wire run, the maximum length per gauge decreases. Determine the new length by dividing the length in Table 2 by the number of detectors on the wire run.
ISN-CP1-CM-W50, ISN-CP1-CM-N100 | Installation Instructions | 3.0 Walk Test 3.0 Walk Test Table 3: DIP Switch Settings Perform a Walk Test at least once a year. 1. Ensure DIP Switch 1-1 (Figure 3 on page 3) is set to DIP Switch/Function...
ISN-CP1-CM-W50, ISN-CP1-CM-N100 | Installation Instructions | 4.0 Coverage Patterns 4.0 Coverage Patterns Figure 6: ISN-CP1-CM-N100 Coverage Patterns Figure 5: ISN-CP1-CM-W50 Coverage Patterns 0 ft 16.5 ft 33 ft 49 ft 65.5 ft 82 ft 98.5 ft 10 m 12 m 14 m 2.8 m...
ISN-CP1-CM-W50, ISN-CP1-CM-N100 | Installation Instructions | 5.0 Troubleshooting Guide 5.0 Troubleshooting Guide Table 4: Detector Troubleshooting Symptom Probable Cause Solution No alarm or the Alarm LED never No power Turn the power ON. lights Damaged wires Change the wires. Improper connection Tighten the screws to improve the connection.