  • Page 1 ISN-CP1-CM-W50, ISN-CP1-CM-N100 Installation Instructions PIR Detector...
  • Page 2: Installation Considerations

    ISN-CP1-CM-W50, ISN-CP1-CM-N100 | Installation Instructions | 1.0 Installation Considerations 1.0 Installation Considerations 2.0 Installation The detector senses intruder movement Do not apply power until after you and notifies an alarm control panel. connect and inspect all wires. Because the detector is only one part of a 1.
  • Page 3 ISN-CP1-CM-W50, ISN-CP1-CM-N100 | Installation Instructions | 2.0 Installation When adding two or more detectors to a Figure 2: PIR Detector Base wire run, the maximum length per gauge decreases. Determine the new length by dividing the length in Table 2 by the number of detectors on the wire run.
  • Page 4: Walk Test

    ISN-CP1-CM-W50, ISN-CP1-CM-N100 | Installation Instructions | 3.0 Walk Test 3.0 Walk Test Table 3: DIP Switch Settings Perform a Walk Test at least once a year. 1. Ensure DIP Switch 1-1 (Figure 3 on page 3) is set to DIP Switch/Function...
  • Page 5: Coverage Patterns

    ISN-CP1-CM-W50, ISN-CP1-CM-N100 | Installation Instructions | 4.0 Coverage Patterns 4.0 Coverage Patterns Figure 6: ISN-CP1-CM-N100 Coverage Patterns Figure 5: ISN-CP1-CM-W50 Coverage Patterns 0 ft 16.5 ft 33 ft 49 ft 65.5 ft 82 ft 98.5 ft 10 m 12 m 14 m 2.8 m...
  • Page 6: Troubleshooting Guide

    ISN-CP1-CM-W50, ISN-CP1-CM-N100 | Installation Instructions | 5.0 Troubleshooting Guide 5.0 Troubleshooting Guide Table 4: Detector Troubleshooting Symptom Probable Cause Solution No alarm or the Alarm LED never No power Turn the power ON. lights Damaged wires Change the wires. Improper connection Tighten the screws to improve the connection.
  • Page 7: Specifications

    ISN-CP1-CM-W50, ISN-CP1-CM-N100 | Installation Instructions | 6.0 Specifications 6.0 Specifications Table 5: Specifications Power Supply 9 VDC to 28 VDC, non-polarized Current Draw 25 mA Coverage ISN-CP1-CM-W50: Wide angle, 14 m (43 ft) maximum range, 15 zone pairs, 30 fingers...
  • Page 8 Bosch Security Systems 130 Perinton Parkway Fairport, NY 14450-9199 Customer Service: (800) 289-0096 Technical Support: (888) 886-6189 © 2005 Bosch Security Systems 4998154997B...