Sony EVI-H100V Operating Instructions Manual

Sony EVI-H100V Operating Instructions Manual

Hd color video camera
Hide thumbs Also See for EVI-H100V:

Advertisement

Available languages

Available languages

Sony Corporation
HD Color
Video Camera
EVI-H100S/H100V
© 2011 Sony Corporation
4-299-489-11 (2)
JP
Operating Instructions _____
GB

Advertisement

Table of Contents
loading

Summary of Contents for Sony EVI-H100V

  • Page 1 4-299-489-11 (2) HD Color Video Camera Operating Instructions _____ EVI-H100S/H100V Sony Corporation © 2011 Sony Corporation...
  • Page 4 ・ ・ ・...
  • Page 15 °...
  • Page 27 Ø145 Ø5, 1/4-20UNC, 53.5 53.5 BOTTOM (Leg) 51.5 51.5 4-Ø9(A)
  • Page 29 1 2 3 4 5 6 7 8 9 VISCA RS-422...
  • Page 31 The nameplate is located on the bottom. For the customers in Europe For the customers in the U.S.A. The manufacturer of this product is Sony This equipment has been tested and found to Corporation, 1-7-1 Konan, Minato-ku, comply with the limits for a Class A digital Tokyo, Japan.
  • Page 32 La plaque signalétique se situe sous rated 12 V dc, 1.0 A max. (for EVI-H100S)/ l’appareil. 0.92 A max. (for EVI-H100V) power supply Pour les clients au Canada marked “Class 2” or “LPS.” In the USA, use an UL Listed power supply.
  • Page 33 Wartungsarbeiten stets nur Für Kunden in Europa qualifiziertem Fachpersonal. Der Hersteller dieses Produkts ist Sony Corporation, 1-7-1 Konan, Minato-ku, WARNUNG Tokyo, Japan. Dieses Gerät hat keinen Netzschalter. Der autorisierte Repräsentant für EMV und Beim Einbau des Geräts ist daher im Produktsicherheit ist Sony Deutschland Festkabel ein leicht zugänglicher...
  • Page 34: Table Of Contents

    Table of Contents Getting Started Appendix Precautions ........35 Message List ........50 Phenomena Specific to CMOS Image Troubleshooting....... 51 Sensors ..........36 Specifications ........52 Using the VISCA RS-422 connector Overview pin assignments ....56 Features ..........37 Supplied Accessories .......37 Location and Functions of Parts and Controls ..........38 Camera ........38...
  • Page 35: Getting Started

    Getting Started maintenance. If abnormal noise occurs, Precautions consult your Sony dealer. Operating or storage location Note on laser beams Operating or storing the camera in the Laser beams may damage the CMOS following locations may cause damage to image sensors. If you shoot a scene that...
  • Page 36: Phenomena Specific To Cmos Image Sensors

    Phenomena Specific to CMOS Image Sensors The following phenomena that may appear in images are specific to CMOS (Complementary Metal Oxide Semiconductor) image sensors. They do not indicate malfunctions. White flecks Although the CMOS image sensors are produced with high-precision technologies, fine white flecks may be generated on the screen in rare cases, caused by cosmic rays, etc.
  • Page 37: Overview

    Overview Features Supplied Accessories • The 1/2.8 type Exmor CMOS camera (utilising approximately 2 million valid When you unpack, check that all the pixels) allows for high-definition shooting supplied accessories are included. with superior picture quality. • Adopts 20 times optical magnification, Camera (1) F1.6 high power and luminous zoom lens.
  • Page 38: Location And Functions Of Parts And Controls

    Wire rope (1) Location and Functions of Parts and Controls Camera Front Screw +M 3×8 (8) VISCA RS-422 connector plug (1) Operating Instructions (1) A Lens This is a 20-magnification optical zoom lens. B Remote sensors C POWER lamp Lights when the camera is turned on. It takes about 7 to 16 seconds to display the image after the lamp lights.
  • Page 39 K HD OUT HD-SDI connector (EVI- H100S) Supplies the images as HD-SDI signal (compliant with SMPTE 292M). EVI-H100V VIDEO OUT connector (EVI- H100V) Supplies the image as digital signals. An analog component signal is also output from this connector.
  • Page 40 Notes • Be sure to set this switch before you turn on the power of the camera. You can also Polarity of the plug set this switch in the standby mode of the Bottom camera. After completing the setting, turn on the power of the camera by connecting it to an AC outlet using the AC power adaptor and AC power cord or by using the...
  • Page 41 Switch Video EVI-H100V EVI-H100S Technical Manual of the camera. For details position format support support on obtaining a Technical Manual, consult 1080i/ your Sony dealer. 59.94(29.97 PsF) Setting of the BOTTOM switches 1080p/29.97 59.94 Hz 720p/59.94 system 720p/29.97 NTSC(LB) OUT) No output –...
  • Page 42: Installation And Connection

    Installation and Connection Installing the Attaching the Camera to a Tripod Camera Attach a tripod to the screw hole used for attaching a tripod on the bottom of the camera. Installing the Camera on a The tripod must be set up on a flat surface Desk and its screws tightened firmly by hand.
  • Page 43 • Always install the supplied wire rope to Attach the wire rope to the junction prevent the unit from falling. box in the ceiling. • If you install the unit in a high location, Use a screw hole and a screw (not check periodically, at least once a year, to supplied) in the junction box to attach ensure that the connection has not...
  • Page 44 Attach the ceiling bracket (B) to the Attach the ceiling bracket (A) to the junction box on the ceiling. bottom of the camera using the 3 × screws (M 3 8) supplied. Align the holes in the bracket with those in the junction box, and use appropriate Align the screw holes on the bottom of screws (not supplied).
  • Page 45 Insert the protrusions raised on the While pushing up on the front part of ceiling bracket (A) into the spaces the camera, attach it using the three × prepared in the ceiling bracket (B), screws provided (M 3 8), starting and temporarily attach them by with the screw at position 1.
  • Page 46: Installing The Camera Using The M3 Fixing Screw Holes

    Removing the camera Connections Remove the 3 screws used to attach the camera in step 6 of “Installation.” Connecting to an AC Outlet While pushing the entire camera up Use the AC power adaptor and AC power towards the ceiling, move the camera cord to connect the camera to an AC outlet.
  • Page 47: Connecting A Computer

    RS-232C Connections malfunction. EVI-H100S/H100V To obtain a cable, consult your Sony dealer. For detailed information on how to connect the camera and the VISCA command list, refer to the Technical Manual of the camera.
  • Page 48: Connecting A Video Monitor, Etc

    VISCA RS-422 cables. Using these cables Connecting a Video Monitor, at the same time may result in etc., Equipped with DVI Input malfunction. Connector EVI-H100V Connecting a Video Monitor, etc., Equipped with an Analog Component Input Connector EVI-H100V DC 12 V...
  • Page 49: Connecting A Video Monitor, Etc

    use a cable for which performance is Connecting a VTR, etc., guaranteed. Equipped with HD-SDI Input • It takes about 7 to 16 seconds to display the image. Connector EVI-H100S Connecting a Video Monitor, etc., Equipped with a Composite video Input Connector EVI-H100S HD OUT...
  • Page 50: Message List

    POWER lamp flash slowly case, “COOLING FAN:NG” appears on PAGE4 of the STATUS in alternation. menu. Turn off the camera, and consult your Sony dealer. The STANDBY lamp and The SYSTEM SELECT switch is set to “no output” (page 40).
  • Page 51: Troubleshooting

    Troubleshooting Before bringing in your camera for service, check the following as a guide to troubleshooting the problem. If the problem cannot be corrected, consult your Sony dealer. Symptom Cause Remedy The picture is not The video cable is not connected...
  • Page 52: Specifications

    EVI-H100S : 1.0 A max. (at 12 V 2.9 (TELE end) to 55.4 degrees (WIDE end) (1080 line mode) EVI-H100V : 0.92 A max. (at 12 V 2.0 (TELE end) to 37.6 degrees (WIDE end) (720 line mode) Operating temperature Minimum object distance 0 ºC to 40 ºC (32 ºF to 104 ºF)
  • Page 53 Design and specifications are subject to change without notice. Note Always verify that the unit is operating properly before use. SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY KIND INCLUDING, BUT NOT LIMITED TO, COMPENSATION OR REIMBURSEMENT ON ACCOUNT...
  • Page 54 Dimensions Back EVI-H100S EVI-H100V Front Side EVI-H100S Ø145(5 1/32) Bottom 72 (2 27/32) 6 (15/64) 164 (6 15/32) EVI-H100V Ø5, depth 5 42(1 21/32) 42(1 21/32) 30(1 3/16) 1/4-20UNC, depth 6.5 Tripod screw hole 53.5 53.5 (2 7/64) (2 7/64)
  • Page 55 VIDEO OUT connector (DVI 29-pin) Pin assignments PLUG & PLAY VISCA IN connector (mini-DIN 8-pin, TMDS ANALOG female) Pin No. Function Data_2 – Pin No. Function Data_2+ DTR IN Shield (2, 4) DSR IN No connection TXD IN No connection No connection RXD IN No connection...
  • Page 56: Using The Visca Rs-422 Connector Pin Assignments

    Using the VISCA RS-422 connector pin assignments Wire The VISCA RS-422 connector pin assignments 1 2 3 4 5 6 7 8 9 VISCA RS-422 Pin No. Function TXD IN+ TXD IN– Flat-head screwdriver RXD IN+ RXD IN– Insert the VISCA RS-422 connector plug into the VISCA RS-422 TXD OUT+ connector on the rear of the camera.

This manual is also suitable for:

Ev-h100sEvi-h100s

Table of Contents