PSA Supa8 User Manual

PSA Supa8 User Manual

Supa8 security alarm system

Advertisement

FACTORY DEFAULTS ................................................................................. 1
INSTALLATION OF THE SECURITY SYSTEM...................................... 2
COMMISSIONING THE DIALLER PANEL ............................................. 5
ZONE INPUT CONNECTIONS.................................................................... 7
PANEL DIAGRAM......................................................................................... 8
THE SUPA8 KEYPAD ................................................................................... 9
SUPA8 OPERATION ................................................................................... 12
HOW TO TURN THE SYSTEM ON. ......................................................... 17
(
(
(
(
HOW TO TURN THE SYSTEM OFF ........................................................ 21
ISOLATING ZONES .................................................................................... 21
PROGRAMMING USER CODES .............................................................. 22
PERSONAL REPORTING .......................................................................... 23
PROGRAMMING TELEPHONE NUMBERS .......................................... 24
OPERATION BY TELEPHONE................................................................. 25
FREQUENTLY ASKED QUESTIONS ...................................................... 26
SYSTEM RECORD SHEET ...................................................................... 278
SUPA8 Quick Setup & User Manual
.......................................................................... 10
....................................................................... 10
....................................................................................... 11
.............................................................................. 11
............................................................................. 12
.............................................................................. 12
) .................................................... 17
) .......................................................... 19
)..................................................... 20
)............................................................ 20
CONTENTS

Advertisement

Table of Contents
loading

Summary of Contents for PSA Supa8

  • Page 1: Table Of Contents

    SUPA8 Quick Setup & User Manual CONTENTS QUICK SETUP & INSTALLATION FACTORY DEFAULTS ................. 1 INSTALLATION OF THE SECURITY SYSTEM........2 COMMISSIONING THE DIALLER PANEL ..........5 ZONE INPUT CONNECTIONS..............7 PANEL DIAGRAM..................8 USER MANUAL THE SUPA8 KEYPAD ................... 9 SUPA8 I ................
  • Page 2: Quick Setup & Installation

    SUPA8 Quick Setup Quick Setup & Installation Thank you for purchasing the SUPA8 Security Alarm System, the following is intended to assist you in the installation of the system. Please read these guidelines before installation. Note: In some States of Australia special licensing may be required in order to install Security Alarms and Associated Equipment.
  • Page 3: Installation Of The Security System

    SUPA8 Quick Setup Installation of the Security System Step 1: Plan out location of all components supplied in your kit as follows: Suggested Locations for Equipment Mounting The 8 Zone Master Panel Box should always be located out of sight (i.e.
  • Page 4 SUPA8 Quick Setup Step 3: Mount devices in the most suitable locations (as suggested in Step 1). Wire cabling directly into devices. At this point install the 4.7K End of the Line (EOL) Resistor. (Refer to Page 7). The feature of this resistor is that when installed at the furthest point in the Zone, tampering or interference with the wiring is not possible without setting off the alarm.
  • Page 5 SUPA8 Quick Setup To DISARM the panel: On Keypad 1234 Enter: (all Zone lights will flash) Followed by: (the off key) Step 8: Walk Test To check operation of all Zones a Walk Test is recommended. On Keypad 1234 Enter:...
  • Page 6: Commissioning The Dialler Panel

    SUPA8 Quick Setup Commissioning the Dialler Panel Austel Requirements: Austel requirement’s state that all Dialler Panels connected to the Telephone Network must have the Telephone connection and termination work performed and completed by a current Austel Licence Holder. To Assign for Local Dialling (to a nominated telephone number) for Self Monitoring Purposes.
  • Page 7 SUPA8 Quick Setup System is now operational as a Self Monitored Dialler. Note: In the event of an alarm, the dialler will emit via the telephone system, a computer generated siren tone. If you are installing a Dialler Panel and do not wish to connect to a telephone line, you MUST default the panel to a local format.
  • Page 8: Zone Input Connections

    SUPA8 Quick Setup Step 4: On Keypad To assign Client Identification Account Number (example No:1111). 160 1111 Enter: 164 1111 Enter: Note: The Account Number must be programmed into both addresses. The above Account Number is allocated by your Central Monitoring Station.
  • Page 9: Panel Diagram

    SUPA8 Quick Setup Panel Diagram...
  • Page 10: User Manual

    User Manual The SUPA8 Keypad The SUPA8 Keypad controls the operation of the SUPA8 alarm panel. It uses a series of command entry keys to input codes that can arm, disarm and program the system. The soft-touch rubber keypad is concealed behind a hinged lid and a series of System and Zone lights run down the right-hand side of the fascia.
  • Page 11: Supa8 Indicator Lights

    All Zone lights flashing Indicates a legal code has been entered (or the key pressed) and the SUPA8 expects another key to be pressed to select the desired function within 10 seconds. To cancel simply wait 10 seconds or press the key.
  • Page 12: Keypad Lockout

    Error type key pressed. No matching code was found. Keypad timeout has occurred. Illegal key in current mode. Illegal mode (either SUPA8 is ON or not in exit delay). Action prevented by a programming option. Address/Action is illegal for this code.
  • Page 13: Supa8 Operation

    SUPA8 User Manual SUPA8 Operation Keypad Key Functions After a code is entered or the key is pressed, you have 10 seconds to select the operation you wish to perform. During this time all 8 Zone lights will flash to indicate that a key should be pressed.
  • Page 14 REVIEW Previous Zone Alarms While in REVIEW mode, pressing Key displays: Zone Light Meaning 1 - 8 Previous alarm on Zones 1 - 8 since the SUPA8’s last reset. Note: The first Zone that was triggered will be flashing.
  • Page 15 SUPA8 User Manual REVIEW Previous Non-Zone Alarms While in REVIEW mode, pressing Key displays: Zone Light Meaning Duress input triggered. Panic input triggered. Test input triggered. Low Battery input triggered. AC Fail input triggered. On input triggered. Fail-to-communicate input triggered.
  • Page 16: Walk Test

    SUPA8 User Manual WALK TEST Selecting this operation whilst the SUPA8 is OFF will initiate walk-test mode. Walk-test can only be performed by holders of user codes 1 to 7. Walk-test mode allows all Zones, the siren and the strobe to be tested.
  • Page 17 10 seconds). Note that isolated Zones only remain isolated until the next time the SUPA8 is turned OFF, even if the SUPA8 is already OFF. AC fail, Low battery, Panic, Test and Duress inputs cannot be isolated.
  • Page 18: How To Turn The System On

    SUPA8 ON in Away Mode. ON light will turn on to indicate SUPA8 is armed in Away Mode. Only Zones which are programmed as Away Zones will be active. All user codes are allowed to arm the SUPA8.
  • Page 19 NOTE: If you make a mistake when you attempt to enter your User code, press the key and try again. AWAY mode (using Quick Away) Your installer may have programmed the SUPA8 to allow abbreviated arming. If so, turn the system ON as follows. Enter ....To clear the keypad Enter ....
  • Page 20: Away Mode (Using Super Codes)

    SUPA8 OFF. Or Enter USER CODE then [any digit] for access to all allowable functions. User Codes 8 to 15 operate as below and can only turn the SUPA8 ON and OFF. Enter USER CODE to turn SUPA8 ON.
  • Page 21: Home Mode (Using Your User Code)

    HOME mode (using Quick Home) Your installer may have programmed the SUPA8 to allow abbreviated arming. If so, turn the system ON as follows. Enter ....
  • Page 22: How To Turn The System Off

    The corresponding lights will turn on. Pressing the Zone number again will turn off the isolation for that Zone. Enter ....To exit isolation mode The system can now be turned ON as normal. Isolated Zones are enabled again the next time you turn the SUPA8 OFF.
  • Page 23: Programming User Codes

    Programming User Codes Use the Master User Code to enter and delete user codes as follows. The Master User Code can re-program other codes as well as turning the SUPA8 ON and OFF. There are 14 user codes plus the Master User Code. All codes are four digits in length.
  • Page 24: Personal Reporting

    Before hanging up, the SUPA8 can be turned ON or OFF, see page 17. If after one minute no key has been pressed, the SUPA8 will hang up and try again. During reporting in personal format mode, prior to a key being pushed by the answering party, the report may be aborted by entering any valid user code on the SUPA8 keypad.
  • Page 25: Programming Telephone Numbers

    SUPA8 User Manual Programming Telephone Numbers Note: To be able to program telephone numbers the SUPA8 must be programmed for personal dialling format. Telephone numbers are programmed at specific addresses in the system memory. Addresses are: Telephone Number 1 Telephone Number 2...
  • Page 26: Operation By Telephone

    If you want to turn the SUPA8 ON, enter your 4 digit user code followed by key on your telephone keypad. If you make a mistake then press key and try again.
  • Page 27: Frequently Asked Questions

    Q How can I tell the system is ON, OFF or in HOME mode? A By looking at the ON light you can tell whether the SUPA8 is ON or OFF. If the ON light is on then the SUPA8 is on in AWAY mode. If the ON light is flashing then the SUPA8 is on in HOME mode.
  • Page 28: System Record Sheet

    At the second level - when the SUPA8 answers the phone, and if no tone is heard for 30 seconds, the SUPA8 will hang up. Finally, if a tone is heard by the SUPA8 only 4 attempts are allowed to enter a legal code, after which the SUPA8 will hang up.
  • Page 29 SUPA8 User Manual Monitoring company: Phone: Entry Delay Exit Delay Siren time Date installed Zone Description Siren Strobe Delay Dialler 24hr Home Away Code Address Name of codeholder: User 0 (Master Code) User 1 (Installer Code) User 2 User 3...

Table of Contents