TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU AL TECHNICAL MANU TECHNICAL MANU AMH95 40" 95% Gas Furnace • Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual.
The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. 95 045 Brand: Minior A: Amana Revision A: Revision Air Flow Direction M:Upflow/Horizontal D: Dedicated Downflow...
Page 3
PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. AMH950453BXA* AMH950703BXA* AMH950704CXA* AMH950904CXA* AMH950905DXA* AMH951155DXA* The United States Environmental Protection Agency (“EPA”) has issued various regulations re- WARNING WARNING garding the introduction and disposal of refrigerants introduced into this unit.
3. Conversion kits for high altitude natural or propane gas General Operation operation are available. See High Altitude Derate chart The AMH95 furnaces are equipped with an electronic igni- for details. tion device used to light the burners and an induced draft 4.
COMPONENT IDENTIFICATION Upflow/Horizontal 1 Gas Valve 17 Electrical Connection Inlets (Alternate) 2 Gas Line Entrance (Alternate) 18 Coil Front Cover Pressure Tap 3 Pressure Switch 19 Coil Front Cover Drain Port 4 Gas Manifold 20 Drain Line Penetrations 5 Combustion Air Intake Connection / “Coupling” 21 Drain Trap 6 Hot Surface Igniter 22 Blower Door Interlock Switch...
Page 6
COMPONENT IDENTIFICATION AMH95*****XA* DISCHARGE DISCHARGE INTAKE PIPE 2" PVC RIGHT SIDE 1 1/2 DRAIN LINE HOLES 1 5/8 UNFOLDED FLANGES UNFOLDED FLANGES FOLDED FLANGES FOLDED FLANGES RIGHT SIDE VIEW Cabinet Size AMH950453BXA* 17-1/2 12-15/16 12-1/8 13-5/8 AMH950703BXA* AMH950704CXA* 19-1/2 15-15/16...
PRODUCT DESIGN PRESSURE SWITCH TRIP POINTS AND USAGE CHART PRESSURE SWITCH TRIP POINTS AND USAGE NEGATIVE NEGATIVE NEGATIVE NEGATIVE PRESSURE PRESSURE PRESSURE PRESSURE 0 to 7,000 ft. 7,001 to 11,000 ft. ID BLOWER ID BLOWER COIL COVER COIL COVER WITH FLUE WITH FLUE WITH FLUE WITH FLUE...
PRODUCT DESIGN ROLLOUT LIMIT SWITCHES Part Number 10123514 or 10123533 Open Setting (°F) AMH950453BXA* AMH950703BXA* AMH950704CXA* AMH950904CXA* AMH950905DXA* AMH951155DXA* AUXILIARY LIMIT SWITCHES Part Number 10123535 10123519 Open Setting (°F) AMH950453BXA* AMH950703BXA* AMH950704CXA* AMH950904CXA* AMH950905DXA* AMH951155DXA*...
Page 9
A large array of Amana brand coils are available for use with the AMH95 furnaces, in either upflow or horizontal applica- tions. These coils are available in both cased and uncased models (with the option of a field installed TXV expansion device).
Page 10
PRODUCT DESIGN Thermostats: NOTE: Complete lineup of thermostats can be found in the Thermostat Specification Sheets. Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty. Upflow Filters This furnace has provisions for the installation of return air filters at the side and/or bottom return.
WIRING DIAGRAMS AMH95[0453,0704,0905]*XAB AMH95[0703,0904,1155]*XAC STAGE DELAY MODE HEAT DELAY NOTE 6 COOL-H 6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS) Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
Page 15
WIRING DIAGRAMS AMH95[0453,0704,0905]*XAC AMH95[0703,0904,1155]*XAD BLOWER INTEGRATED HUMIDIFIER 24 VAC COMPARTMENT CONTROL MODULE HUMIDIFIER DOOR SWITCH TR (6) (OPEN WHEN 24 VAC DOOR OPEN) GND (8) 40 VA MVC (9) TRANSFORMER 115 VAC VALVE MVH (12) 24V THERMOSTAT CONNECTIONS MVL(2) ID BLOWER...