Excell SK-VET Service Manual

Excell SK-VET Service Manual

Weighing scale

Advertisement

EXCELL PRECISION CO., LTD
.
©
Excell Precision Limited 2005. All rights reserved Worldwide.
The information contained herein is the property of Excell Precision Limited and is supplied
without liability for errors or omissions. No part may be reproduced or used except as
authorised by contract or other written permission.
The copyright and the foregoing
restriction on reproduction and use extend to all media in which the information may be
embodied.
SK-VET V1.0
SME300000067

Advertisement

Table of Contents
loading

Summary of Contents for Excell SK-VET

  • Page 1 © Excell Precision Limited 2005. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission.
  • Page 3: Table Of Contents

    EXCELL PRECISION CO., LTD TABLE OF CONTENTS BEFORE USING THE SCALE..................2 SAFTY INSTRUCTIONS....................2 PREPARING TO USE THE SCALE.................. 3 CHAPTER 1 FEATURES AND SPECIFICATIONS ............4 CHAPTER 2 DISPLAY ...................... 6 CHAPTER 3 KEYBOARD FUNCTION ................7 CHAPTER 4 SERVICE MODE ACCESS................8 4-1.
  • Page 4: Before Using The Scale

    EXCELL PRECISION CO., LTD BEFORE USING THE SCALE Thank you for purchasing an EXCELL Electronic Digital Scale. In order to use the scale properly, please read this User Manual carefully before use. If you have a problem concerning the scale, please contact your supplier.
  • Page 5: Preparing To Use The Scale

    EXCELL PRECISION CO., LTD PREPARING TO USE THE SCALE 1. For accurate weight readings locate the scale on a firm level surface free from vibrations. 2. Avoid operating the scale in direct sunlight or drafts of any kind. 3. Remove any weight that might be on the weigh pan before the scale is switched on and avoid leaving weight on the pan for long periods of time.
  • Page 6: Chapter 1 Features And Specifications

    EXCELL PRECISION CO., LTD CHAPTER 1 FEATURES AND SPECIFICATIONS Features: Multi-function operation: Fast weighing operation; Full range tare; Auto power-off; Weight hold feature. Dual-weighing units: Pound (lb) and kilogram (kg). User-friendly design: Auto calibration; Large LCD display (digit height 12mm x 25mm);...
  • Page 7: Error Messages

    EXCELL PRECISION CO., LTD Selectable Weight Units and Piece Unit: Kilogram (kg) 1 g = 0.001 kg Gram 1 g = 1 g Pound (lb) 1 g = 0.002204623 lb Pound/Ounce (lb, oz) 1 g = 0.03527396 oz Ounce (oz) 1 g = 0.03527396 oz...
  • Page 8: Chapter 2 Display

    EXCELL PRECISION CO., LTD CHAPTER 2 DISPLAY TARE: “Tare” indication. ZERO: “Zero” indication. ► 1: Kilogram (kg), the 1 unit indication. ► 2: Pound (lb), the 2 unit indication. ► 3: Hold mode indication. : “Low Battery” indication. SK-VET V1.0...
  • Page 9: Chapter 3 Keyboard Function

    EXCELL PRECISION CO., LTD CHAPTER 3 KEYBOARD FUNCTION : The key to switch the scale off. ZERO : ON/ZERO key. When the scale is off, press the key to switch it on. When the scale is switched on, with the weigh pan empty, if the display is not showing zero, press this key to zero (balance) the scale.
  • Page 10: Chapter 4 Service Mode Access

    EXCELL PRECISION CO., LTD CHAPTER 4 SERVICE MODE ACCESS Set the jumper SWA1 on the main board to the ADJ position (EEPROM UNLOCKED). Press and hold the key, followed by pressing the TARE key. Release the key first and then the...
  • Page 11: Capacity Configuration

    EXCELL PRECISION CO., LTD 4-1. Capacity Configuration ⇒ Increment digit (from 0 to 9) ON/ZERO ⇒ Confirm / enter key TARE Press the TARE ⇒ Move the cursor to the right HOLD Input the parameter “01” to enter the capacity...
  • Page 12 EXCELL PRECISION CO., LTD Refer to “Note 3” Example: 1 ⇒ Division size 1 ⇒ The number of decimal places 0 ⇒ range setting Press the TARE The display shows the max. capacity of the scale + minimum division and the unit weight for 2 seconds.
  • Page 13 EXCELL PRECISION CO., LTD NOTE 1 The users can set up the different weight units in various orders according to their preference, and the amount of the chosen weight units can be up to 4. (a) (b) (c) (a) ⇒ The first weight unit (only “kg”, or “lb” are available to choose from).
  • Page 14: Weight Calibration

    EXCELL PRECISION CO., LTD 4-2. Weight Calibration ⇒ Increment digit (from 0 to 9) ON/ZERO ⇒ Confirm / enter key TARE Press the TARE ⇒ Move the cursor to the right HOLD Input the parameter “01” The display shows the calibration weight...
  • Page 15: Function Settings

    EXCELL PRECISION CO., LTD 4-3. Function Settings Press the TARE Input a parameter 00, 01, or After inputting “00”, ⇒ Increment digit (from 0 to 9) ON/ZERO Press the TARE ⇒ Confirm / enter key TARE to return to the upper level ⇒...
  • Page 16: Environment Settings

    EXCELL PRECISION CO., LTD 4-3-1 Environment Settings Returning to zero point setting Displays the current setting Returning to zero point setting Use the key to input a ON/ZERO Press the TARE parameter Default setting = 0 0 ⇒ show all 5 ⇒...
  • Page 17 EXCELL PRECISION CO., LTD Stable range parameter setting The display shows the current setting. Cont. Press the TARE Stable range parameter setting Use the key to input a parameter ON/ZERO Default setting = 1 0 ⇒ No limitation Use the key to 1 ⇒...
  • Page 18: Buzzer Type

    EXCELL PRECISION CO., LTD 4-3-2 Buzzer Type Press the TARE Buzzer type The display shows the current setting Use the key to ON/ZERO Buzzer type key in a parameter Use the key to key in a parameter ON/ZERO 0 ⇒ Pulse signal (AC buzzer, PT-134OP, 4KHz) 1 ⇒...
  • Page 19: 4-4.Span Calibration

    EXCELL PRECISION CO., LTD 4-4.Span Calibration Set the jumper SWA1 on the main board to the ADJ position (EEPROM UNLOCKED). Press the key to enter the SPAN calibration mode; ON/ZERO the display shows Set the jumper SWA1 back to the LOCK position, after completing the calibration.
  • Page 20: 4-5.Gravity Compensation

    EXCELL PRECISION CO., LTD 4-5.Gravity Compensation Set the jumper SWA1 on the main board to the ADJ position. Press the ON/ZERO key to switch on the scale, and press the key again before the display ON/ZERO resets back to zero. The scale enters the gravity compensation mode.
  • Page 21: Chapter 5 Advanced Functions

    EXCELL PRECISION CO., LTD CHAPTER 5 ADVANCED FUNCTIONS 5-1. Auto Power off and Backlight Settings Switch on the scale, press the and the keys together to enter the advanced ON/ZERO HOLD function settings mode. The display shows 。 The display shows the current setting...
  • Page 22 EXCELL PRECISION CO., LTD Cont. Hold function setting LCD displays the last current setting Press the TARE Hold function setting Use the key to ON/ZERO Use the key to key in a parameter ON/ZERO enter a parameter Default setting = 0 0 ⇒...
  • Page 23 EXCELL PRECISION CO., LTD NOTE 4 parameter setting (Animal Weighing mode) (a) (b) (c) (d) (e) (a) ⇒ Parameters 0~4 to set the stabilization timer 0: 0.5 second 1: 1 second 2: 2 seconds (default setting) 3: 4 seconds 4: 8 seconds (b) (c) (d) (e) ⇒...
  • Page 24: Appendix

    EXCELL PRECISION CO., LTD APPENDIX 7 SEGMENT DISPLAY CHARACTERS 7 segments 7 segments 7 segments Digit Alphabet Alphabet letter letter letter SK-VET V1.0 SME300000067...

This manual is also suitable for:

Sk-vet-150Sk-vet-300

Table of Contents