Samsung MH026FKEA Installation Manual

Free joint multi air conditioner (cool and heat)
Hide thumbs Also See for MH026FKEA:

Advertisement

INSTALLATION MANUAL
MANUAL DE INSTALACIÓN
MANUEL D'INSTALLATION
MANUALE D'INSTALLZIONE
MANUAL DE INSTALAÇÃO
INSTALLATIONS-HANDBUCH
E°XEIPI¢IO E°KATA™TA™H™
àçëíêìäñàü èé ìëíÄçéÇäÖ
MH026FKEA
MH035FKEA
Free Joint Multi Air Conditioner
(Cool and Heat)
Acondicionador de aire libre del empalme multi
(Refrigeración y Calefacción)
Climatiseur Free Joint Multi
(Refroidissement et Chauffage)
Aria condizionata Free Joint Multi
(Raffreddamento e Riscaldamento)
Free Joint Multi ar condicionado
(Refrigeração e Aquecimento)
Free Joint Multi Klimaanlage
(Kühlen und Wärmen)
¶ÔÏÏ·Ïfi ∫ÏÈÌ·ÙÈÛÙÈÎfi ªË¯¿ÓËÌ· ∂χıÂÚ˘ ŒÓˆÛ˘
(æ‡Í˘ - £¤ÚÌ·ÓÛ˘)
å å Ì Ì Ó Ó „ „ Ó Ó Ù Ù Û Û Ì Ì Í Í ˆ ˆ Ë Ë Ó Ó Ì Ì ‡ ‡ Î Î ¸ ¸ Ì Ì ˚ ˚ È È Ç Ç Ó Ó Á Á ‰ ‰ Û Û ¯ ¯ Ì Ì ˚ ˚ È È ä ä Ó Ó Ì Ì ‰ ‰ Ë Ë ˆ ˆ Ë Ë Ó Ó Ì Ì Â Â   ë ë ‚ ‚ Ó Ó · · Ó Ó ‰ ‰ Ì Ì Ó Ó „ „ Ó Ó ë ë Ó Ó Â Â ‰ ‰ Ë Ë Ì Ì Â Â Ì Ì Ë Ë fl fl
( ( é é ı ı Î Î ‡ ‡ Ê Ê ‰ ‰ Â Â Ì Ì Ë Ë Â Â Ë Ë é é · · Ó Ó „ „   Â Â ‚ ‚ ) )
E S F I P D G R DB98-20239A(4)

Advertisement

Table of Contents
loading

Summary of Contents for Samsung MH026FKEA

  • Page 1 MANUAL DE INSTALACIÓN MANUEL D’INSTALLATION MANUALE D’INSTALLZIONE MANUAL DE INSTALAÇÃO INSTALLATIONS-HANDBUCH E°XEIPI¢IO E°KATA™TA™H™ àçëíêìäñàü èé ìëíÄçéÇäÖ MH026FKEA MH035FKEA Free Joint Multi Air Conditioner (Cool and Heat) Acondicionador de aire libre del empalme multi (Refrigeración y Calefacción) Climatiseur Free Joint Multi...
  • Page 2: Safety Precautions

    Safety Precautions The following safety precautions must be taken when using your air conditioner. Risk of electric shock. • Can cause injury or death. • Disconnect all WARNING remote electric power supplies before servicing, installing or cleaning. • This must be done by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard.
  • Page 3: Table Of Contents

    Contents REPARING THE NSTALLATION Deciding on Where to Install the Air Conditioner ......... Air Conditioner and Accessories ..............NSTALLING THE NDOOR Deciding on Where to Install the Indoor Unit ..........Indoor Unit Installation ................. Purging the Unit ................... Connecting the Refrigerant Pipe ..............Cutting/Flaring the Pipes ................
  • Page 4: Preparing The Installation

    REPARING THE NSTALLATION Deciding on Where to Install the Air Conditioner When deciding on the location of the air conditioner with the owner, the following restrictions must be taken into account. General Do NOT install the air conditioner in a location where it will come into contact with the following elements: Combustible gases Saline air Machine oil...
  • Page 5 REPARING THE NSTALLATION MH040FXEA2 / MH052FXEA2 The split type, 1-way cassette, slim duct type indoor units can be installed together. Piping outside diameter Outside diameter Power supply Unit Indoor unit Outdoor unit Ø, V, Hz Liquid MH040FXEA2 026/035 1, 220-240, 50 026/035 1/4”...
  • Page 6 REPARING THE NSTALLATION Deciding on Where to Install the Air Conditioner (Continued) MH068FXEA4 / MH080FXEA4 The split type, 1-way cassette, duct type indoor units can be installed together. Piping outside diameter Outside diameter Power supply Unit Indoor unit Outdoor unit Ø, V, Hz Liquid MH068FXEA4...
  • Page 7: Air Conditioner And Accessories

    REPARING THE NSTALLATION Air Conditioner and Accessories Accessories in the Indoor Unit Case The following accessories are supplied with the indoor unit. The type and quantity may differ depending on the specifications. Insulation cover drain Pattern sheet Insulation refrigerant pipe Flexible hose Insulation drain Rubber...
  • Page 8: Installing The Indoor Unit

    NSTALLING THE NDOOR Deciding on Where to Install the Indoor Unit Indoor Unit There must be no obstacles near the air inlet and outlet. Install the indoor unit on a ceiling that can support its weight. Maintain sufficient clearance around the indoor unit. Make sure that the water dripping from the drain hose runs away correctly and safely.
  • Page 9 NSTALLING THE NDOOR Drawing of the indoor unit Unit : mm Name Remark Liquid pipe connection ø6.35 Gas pipe connection ø9.52 Drain pipe connection Power supply connection Air discharge grille Air suction grille...
  • Page 10: Indoor Unit Installation

    NSTALLING THE NDOOR Indoor Unit Installation It is recommended to install the refnet joint before installing the indoor unit. Place the pattern sheet on the ceiling at the spot where you want to install the indoor unit. Since the diagram is made of paper, it may shrink or stretch slightly due to temperature or humidity.
  • Page 11: Purging The Unit

    NSTALLING THE NDOOR Purging the Unit On delivery, the indoor unit is loaded with refrigerant gas. All this gas must therefore be purged before connecting the assembly piping. To purge the inert gas, proceed as follows. Unscrew the pinch pipe at the end of each refrigerant pipe. Result: All inert gas escapes from the indoor unit.
  • Page 12: Connecting The Refrigerant Pipe

    NSTALLING THE NDOOR Connecting the Refrigerant Pipe There are two refrigerant pipes of differing diameters: A smaller one for the liquid refrigerant A larger one for the gas refrigerant The inside of copper pipe must be clean & has no dust. Remove the pinch pipe on the pipes and connect the assembly pipes to Refrigerant oil each pipe, tightening the nuts, first manually and then with a torque...
  • Page 13: Cutting/Flaring The Pipes

    NSTALLING THE NDOOR Cutting/Flaring the Pipes Make sure that you have the required tools available (pipe cutter, reamer, flaring tool and pipe holder). If you wish to shorten the pipes, cut it with a pipe cutter, taking care to ensure that the cut edge remains at a 90° angle with the side of the pipe. Refer to the illustrations below for examples of edges cut correctly and incorrectly.
  • Page 14: Performing Leak Test & Insulation

    NSTALLING THE NDOOR Performing Leak Test & Insulation Leak Test To check for gas leaks on the indoor unit, check the connection part of each refrigerant pipe by using a leak detector. Insulation Once you have checked that there are no leaks in the system, you can insulate the piping and hose.
  • Page 15: Drainpipe And Drain Hose Installation

    NSTALLING THE NDOOR Drainpipe and Drain Hose Installation Care must be taken when installing the drainpipe and drain hose for Flexible the indoor unit so that condensate water is drained correctly outside. hose Drainpipe Fix the flexible hose to the drainpipe. The connection port of the flexible hose and PVC drainpipe must be fixed with PVC adhesives.
  • Page 16: Testing The Drainage

    NSTALLING THE NDOOR Drainpipe and Drain Hose Installation (Continued) Lift-up Drain piping If it is necessary to increase the height of the drain hose somewhat, install a lift-up drain piping. Connect a lift-up drain pipe top to the drain hose with an adhesive for PVC.
  • Page 17: Connecting The Connection Cord

    NSTALLING THE NDOOR Connecting the Connection Cord The indoor unit is powered from the outdoor unit via the connection cord. Remove the screw on the electrical component box and remove the cover plate. Route the connection cord through the side of the indoor unit and connect the cable to terminals;...
  • Page 18: Wiring Wired Remote Controller (Optional)

    NSTALLING THE NDOOR Wiring Wired Remote Controller (Optional) Connect the power cable, which is connected with the outdoor unit and supplied by another source, making sure that the power cable terminal should not be changed. The F3 and F4 communication cable may be cross-connected, however, it is recommended that they are connected to the corresponding F3 and F4 terminal.
  • Page 19: Assigning Address To Indoor Unit

    NSTALLING THE NDOOR Assigning Address to Indoor Unit Before installing the indoor unit, assign an address to the indoor unit according to the air conditioning system plan. The address of the indoor unit is assigned by adjusting MAIN(SW02). K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 SW01 MAIN SW02 MAIN...
  • Page 20: Additional Functions

    NSTALLING THE NDOOR Additional Functions Compensation for lost temperature in heating operation Reduces the difference between an actual room temperature and a sensed temperature by the air conditioner when heating. K5 K6 K7 K8 Switch No. Switch ON Switch OFF 2°C compensation 5°C compensation SW05...
  • Page 21: Bio-Pure Filter Installation(Optional)

    NSTALLING THE NDOOR Bio-pure Filter Installation (Optional) The air conditioner can be fitted with a Bio-Pure or deodorizing filter to remove minute dust particles or odours. The service life of the filter is approximately three months depending on the time during which the air conditioner is used. Accessories Deodorizing Bio-pure filter...
  • Page 22: Completing The Installation

    OMPLETING THE NSTALLATION Troubleshooting Detection of errors If an error occurs during the operation, an LED flickers and the operation is stopped except the LED. If you re-operate the air conditioner, it operates normally at first, then detect an error again. LED Display on the indoor unit LED Display Indicators...
  • Page 23 OMPLETING THE NSTALLATION LED Display Indicators Abnormal conditions Operating Green 1. 2nd detection of refrigerant completely leak Displayed on appropriate indoor unit which is operating 2. 2nd detection of high temperature COND Displayed on outdoor unit 3. 2nd detection of high temperature DISCHARGE 4.
  • Page 24 THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: QUESTO CONDIZIONATORE D’ARIA È PRODOTTO DA: ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR: DIESE KLIMAANLAGE IST FABRIZIERT VON: AYTH H ™Y™KEYH KATA™KEYA™THKE A¶O: ùíéí...