Viessmann VITODENS 200 WB2 Series Operating Instructions & User's Information Manual

Viessmann VITODENS 200 WB2 Series Operating Instructions & User's Information Manual

Wall-mounted, gas-fired condensing boiler
Hide thumbs Also See for VITODENS 200 WB2 Series:

Advertisement

Operating Instructions &
User's Information Manual
Vitodens 200
WB2 Series
Wall-mounted, gas-fired condensing boiler
For natural gas and liquid propane
Heating input NG
25 to 230 MBH
7 to 67 kW
Heating input LP
25 to 214 MBH
7 to 63 kW
VITODENS 200
IMPORTANT
Read and save these instructions
for future reference.
5167 475 v1.2 07/2007
WARNING
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable
liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliances.
Do not touch any electrical switches, do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
WARNING
Improper installation, adjustment, and/or
operation could cause carbon monoxide
poisoning resulting in injury or loss of life.
This product must be installed and serviced by a
professional service technician who is
experienced and qualified in hot water boiler
installation and gas combustion.

Advertisement

Table of Contents
loading

Summary of Contents for Viessmann VITODENS 200 WB2 Series

  • Page 1: Operating Instructions

    Operating Instructions & User’s Information Manual Vitodens 200 WB2 Series Wall-mounted, gas-fired condensing boiler For natural gas and liquid propane Heating input NG 25 to 230 MBH 7 to 67 kW Heating input LP 25 to 214 MBH 7 to 63 kW VITODENS 200 WARNING If the information in this manual is not followed...
  • Page 2 Safety, Installation and Warranty Requirements Safety, Installation and Warranty Requirements Please ensure that these instructions are read and understood before commencing installation. Failure to comply with the instructions listed below and details printed in this manual can cause product/property damage, severe personal injury, and/or loss of life. Ensure all requirements below are understood and fulfilled (including detailed information found in manual subsections).
  • Page 3: Table Of Contents

    Index Page General Information About these Instructions ............Safety For your Safety .
  • Page 4 Emission Inspection Override Switch/Emission Test Switch ......Information Troubleshooting Guide ............Diagnosis and correction .
  • Page 5: About These Instructions

    Your heating contractor proper qualifications and hold all to the performance of the Viessmann should always perform the initial start-up necessary licenses. Vitodens 200. Neglected maintenance and explain the system. Any warranty is impacts on warranty;...
  • Page 6 (if so equipped). Note: CAUTION - Ensure that nothing is obstructing the Viessmann does not test any detectors flow of combustion and ventilation air Should overheating occur or the gas and makes no representation regarding and no chemicals, garbage, gasoline, supply fail to shut off, do not any brand or type of detector.
  • Page 7 Safety For your Safety (continued) Frozen water pipe hazard If your home will be unattended for an extended period of time during cold weather, you should... WARNING Shut off the water supply to the Failure to protect against frozen pipes building, drain the water pipes and add could result in burst water pipes, an antifreeze for potable water to drain...
  • Page 8 Safety For your Safety (continued) If you notice fire coming from the Installation area conditions Sources of combustion and ventilation air appliance, call the fire department contaminants immediately! Do not attempt to extinguish WARNING the fire unless qualified to do so. Areas likely to contain contaminants: Incorrect ambient conditions can lead to New building construction...
  • Page 9: Inform Yourself

    Inform Yourself Getting Started... The timer of the control unit switches between ”normal room temperature” and ”reduced room temperature” at the required times. Times and duration of the two room 1. Normal room temperature for the times you spend at home and temperatures can be set on the require a comfortably warm room programming unit of your control.
  • Page 10: Your Vitodens 200 Boiler

    Inform Yourself Your Vitodens 200 Boiler Please ask your heating contractor to check off the appropriate box ( ). j Vitodens 200 j Vitodens 200 j Vitodens 200 without domestic hot water tank with separate domestic hot water with integrated DHW plate heat tank exchanger for instantaneous DHW heating...
  • Page 11 Inform Yourself Overview of Controls and Indicators (continued) Operation The is a menu-driven programming unit. Upon opening the flip-down cover of the programming unit, the start menu showing all available adjustment options will appear MAIN MENU in the display window. Select your Please select >HTG.
  • Page 12: Ready For Operation

    Ready for Operation The Main Control Options All settings can be adjusted directly on the boiler control or on the remote control (when the programming unit is used as remote control). The programming unit can be removed from the control unit and mounted on a wall-mount base (available as accessory) anywhere in your main living area and used as a remote control.
  • Page 13: Selecting A Heating Program (Winter, Summer)

    Ready for Operation Selecting a Heating Program (winter, summer) Select one of the following heating programs according to your personal requirements. Space heating and domestic hot water e.g. for winter months and transitional H Space heating at periods. normal or reduced room temperature according to preset switching times H Domestic hot water production...
  • Page 14: Changing Room Temperature

    Ready for Operation/Using Comfort Functions Changing Room Temperature In the ”Space heating and domestic hot water” heating program, space heating takes place at ”normal room temperature” and ”reduced room temperature” depending on preset switching times. You can set the required room temperature as follows. ”Normal room temperature”...
  • Page 15: Setting The Party Mode

    Using Comfort Functions Setting the Party Mode Activate the party mode when you require space heating for a short period of time, independent of the preset heating program and outside the preset switching times. You can adjust the room temperature (party temperature) to suit your personal preference. To activate the party mode Example Press the party button ”g”.
  • Page 16: Using The Remote Programming Option

    Using Comfort Functions/Switching On and Off Using the Remote Programming Option The programming unit provides you with the option of programming your right from your armchair. Simply remove the programming unit from the control base in the 3 4 6 7 front of the boiler or, if used as remote control, from the wall-mount base, and perform your programming from wherever convenient.
  • Page 17: Shutting Down The Heating System

    Switching On and Off Shutting Down the Heating System In case you are not intending to use your heating system for a period of time, e.g. during your summer holidays, switch your heating system to standby operation (see section entitled ”Selecting a heating program”, page 13). If you do not want to use your heating system for a longer period of time (several months), you should shut it down.
  • Page 18: Menu-Driven Operation

    Menu-driven Operation The Programming Unit Is Your Assistant With the programming unit you can set the heating system settings according to your personal preferences and requirements by using the various functions and adjustment options offered through the programming unit. Most of the functions offered are easily accessible through the main menu.
  • Page 19: Space Heating Settings (Switching Times)

    Space Heating Settings (Switching Times) How Switching Times Work ... By setting the switching times In the factory default setting, space accordingly, space heating can switch heating takes place at ”normal room up to 4 times a day between ”normal temperature”...
  • Page 20 Central Heating Settings (Switching Times) Scanning and Changing Switching Times (continued) To change switching times for other days of the week Press the following buttons: for ”Heating circuit A” 1. A Examples: Select ”MO” if you wish to change the for ”Heating circuit B”...
  • Page 21: Domestic Hot Water Supply Settings (Switching Times)

    Domestic Hot Water Supply Settings (Switching Times) How Switching Times Work ... On Vitodens 200 boilers equipped with In the factory default setting, domestic a stand-alone domestic hot water hot water production takes place storage tank, domestic hot water continuously between 6:00 hrs until production can be switched on and off 22:00 hrs every day of the week.
  • Page 22 Domestic Hot Water Supply Settings (Switching Times) Scanning and Changing Switching Times (continued) To change switching times for other days of the week Press the following buttons: 1. C for ”DHW” Examples: Select ”MO” if you wish to change for ”DHW tank” the switching times for Monday only.
  • Page 23: Changing The Domestic Hot Water Temperature

    Domestic Hot Water Supply Settings (Switching Times) Changing the Domestic Hot Water Temperature Only on boiler with separate DHW tank You can select the domestic hot water temperature according to your personal preference (e.g. for showering). Press the following buttons: 1.
  • Page 24: When You Go On Holidays

    When you go on holidays ... Setting the Energy Saving Mode for the Holiday Period When going away on a holiday and you wish to reduce the energy consumption of your heating system as much as possible, select one of the following heating programs.
  • Page 25: Other Settings

    Other Settings Changing Time and Date (if required) Press the following buttons: SYSTEM / CLOCK 1. D for ”System” TODAY IS THURSDAY for ”Factory setting” 2. A 21.08.97 15:30 HRS 3. A for ”Clock” >CHANGE DATE: ..A >CHANGE TIME: ..B You are now in the ”Clock”...
  • Page 26: Changing The Heating Pattern Of The Boiler

    Other Settings Changing the Heating Pattern of the Boiler The heating pattern of your boiler is determined by the outdoor temperature and the settings of the ”shift” and ”slope” of the ”heating curve”. You may change these settings if you feel that the room temperature does not meet your requirements during the heating season over a longer period of time.
  • Page 27 Other Settings Changing the Heating Pattern of the Boiler (continued) Change heating pattern if ... Action Example ... your living area is too cold Adjust slope of heating curve upward HC A / HTG. CURVE at cold time of year by one increment SLOPE: SHIFT:...
  • Page 28 Emission Inspection Override Switch/Emission Test Switch The following information is provided for emission inspection purposes, and for temporary override of the outdoor reset control. For flue gas measurement at constant Override/Emission boiler water temperature for a short test switch period of time: =Manual 1.
  • Page 29: Troubleshooting Guide

    Troubleshooting Guide Diagnosis and Correction If a fault occurs on your heating system, it will be displayed in the display window TUESDAY, 25.06.97 with the cover closed. Using the scanning function, you can access the fault 15:20 HRS cause in the display and inform your heating contractor accordingly. PROGRAM SPACE HEATING: ON BOILER TEMP.: 53ºC...
  • Page 30 Troubleshooting Guide Diagnosis and Correction (continued) Fault Cause Corrective Action Heating system does not start up Heating system switch turned to OFF Turn switch to ON on control unit. on control unit Circuit breaker or fuse in power Inform heating contractor. supply, in power/pump module or in boiler control unit has blown or tripped Burner does not switch on or only...
  • Page 31 Troubleshooting Guide Diagnosis and Correction (continued) Fault Cause Corrective Action ”Please change batteries” appears in Batteries discharged 1. Switch off heating system on/off display window switch on the control unit as well as line voltage. Display window fails to illuminate 2.
  • Page 32: Service Instructions

    Service Instructions Service Instructions for Your Heating System Viessmann strongly recommends inspection/service of the boiler and the system by a licensed professional heating contractor once a year. Before the heating season begins, the boiler with its burner(s) and direct vent system should be serviced by a qualified heating contractor.
  • Page 33 How to Save Energy How to Save Energy ..by heating correctly Apart from taking advantage of the benefits of a modern heating system, there is a lot you can do yourself to achieve additional fuel savings. For instance: H Don’t overheat: H Make use of individual adjustment Aim at a room temperature of options of the control unit 4;...
  • Page 34 Directories Overview of Menu Structures The main menu provides you with options which direct you to further functions and information. The overview is displayed upon opening the cover of the programming unit. Menu structure – Heating circuits A and B >HEATING CIRCUIT A >TIMER >SWITCHING TIMES...
  • Page 35 Directories Overview of Menu Structures (continued) Menu structure – Domestic hot water >HEATING CIRCUIT A >DHW TANK >TIME SCHEDULE >TIME SCHEDULE >HEATING CIRCUIT B >DHW RECIRC. >TEMPERATURE >DIFFERENT DAYS >DOMESTIC HOT PUMP >OPERATING WATER STATUS >CHANGE TEMPERATURE >SYSTEM >DHW TANK STATUS >TIME SCHEDULE >TIME SCHEDULE >OPERATING STATUS...
  • Page 36: For Your Safety Read Before Operating

    Information Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE OPERATING W A R N I N G: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A.
  • Page 37 Directories Alphabetical Index Changing the batteries, 31 Heating contractor, 2, 32 Safety, 5, 2 Changing the date, 25 Heating curve, 26 Saving energy, 33 Changing the domestic hot water Heating pattern, 26 Scanning the operating status, 25 temperature, 23 Heating program selector switch, 10 Scanning the temperature values, 25 Changing the room temperature, 14 Heating system on/off switch, 10, 17...
  • Page 40 +60 +140 +70 +158 +80 +176 +90 +194 +100 +212 +110 +230 Viessmann Manufacturing Company (U.S.) Inc. Viessmann Manufacturing Company Inc. 45 Access Road 750 McMurray Road Warwick, Rhode Island • 02886 • USA Waterloo, Ontario • N2V 2G5 • Canada Tel.

Table of Contents