Dyna-Glo Delux RMC-FA300DGD Operating Instructions & Parts Manual

Dyna-Glo Delux RMC-FA300DGD Operating Instructions & Parts Manual

Propane construction heater

Advertisement

Operating Instructions & Parts Manual
Dyna-Glo
Propane Construction Heater
Description
Dyna-Glo
TM
Delux Model RMC-FA300DGD heaters are 300,000 BTU/Hr construction
heaters. This heater uses propane gas for combustion, and electricity to run the
fan. It is primarily intended for temporary heating of well-ventilated buildings
under construction, alteration or repair. This heater should be utilized in sheltered,
well-ventilated areas, but never in occupied dwellings.
Electrical Specifications
Model
Electrical Input
RMC-FA300DGD
120 V, 60 Hz
General Specifications
Output Rating
Model
BTU/Hr
RMC-FA300DGD
300,000
Hot Air Output
Model
Approx. (CFM) Motor
RMC-FA300DGD
1800

Table of Contents

Description . . . . . . . . . . . . . . . . . . . . . . .1
Specifications. . . . . . . . . . . . . . . . . . . . . .1
Unpacking . . . . . . . . . . . . . . . . . . . . . . . 1
General Safety Information . . . . . . . . 1-3
Theory of Operation. . . . . . . . . . . . . . . .3
Installation. . . . . . . . . . . . . . . . . . . . . . 3-4
Ventilation. . . . . . . . . . . . . . . . . . . . . . . .4
Operation . . . . . . . . . . . . . . . . . . . . . . 4-5
Maintenance . . . . . . . . . . . . . . . . . . . . 5-6
Storage . . . . . . . . . . . . . . . . . . . . . . . . . .6
Wiring Diagram. . . . . . . . . . . . . . . . . . . .6
Repair Parts Illustration
and Parts List . . . . . . . . . . . . . . . . . . . . 7-8
Troubleshooting Chart . . . . . . . . . . . . . .9
Warranty . . . . . . . . . . . . . . . . . . . . . . . .10
Unpacking
1. Unpack all materials used to protect
the heater inside of carton. Retain
plastic caps attached to exposed
fittings for use during storage.
www.ghpgroupinc.com
Printed in China
Delux
TM
Amperage
0.65
CSA 2.14b-2009, ANS Z83.7b-2009 Construction Heater
Fuel
Propane Vapor Only
Minimum Supply
Pressure to Regulator
0.085 HP
25 PSIG (For purposes
1,720 RPM
of input adjustment)
Page
2. Remove heater, accessories and all
hardware from carton.
3. Inspect all items for damage that may
have occurred during shipment.
General Safety Information
Make certain you read and understand
all warnings. Keep this instruction
manual for future reference, and use it
as a guide to safe and proper operation
of the heater.
Various precautions appear throughout
this manual. Please review and pay
close attention to them. Below is an
explanation of the various levels of
caution required while operation this
heater.
DANGER
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
C
US
Maximum Fuel
Consumption
Ignition
13.9 Lbs/Hr
Direct Spark, Interrupted
Maximum Supply
Pressure to Regulator
Max Bottle Pressure
Indicates an
im minen tly
RMC-FA300DGD
Figure 1 - Model RMC-FA300DGD
Regulator
Outlet Pressure
7-10 PSIG
Size
Weight
L x W x H (Inches)
(pounds)
33.7 x 12.6 x 18.5
33.9 (Heater)
42 (Shipping)
WARNING
Indicates a poten-
tially hazardous
situation which, if not avoided, COULD
result in death or serious injury.
CAUTION
Indicates a poten-
tially hazardous
situa tion which, if not avoided, MAY
result in minor or moderate injury.
IMPORTANT: Every possible situation
that may involve a hazard cannot
be anticipated. The warnings in this
manual and on the heater itself
cannot be all inclusive. If an operating
technique or procedure that is not
specifically recom mend ed is used, you
must assure that it is safe for you and
anyone else within the heated space.
You must be sure that the heater will
not be damaged or made unsafe by
your handling of the maintenance or
operation of the heater.
Consumer: Retain this manual for future
reference.
Rev. 2011-01-28
PROFESSIONAL GRADE

Advertisement

Table of Contents
loading

Summary of Contents for Dyna-Glo Delux RMC-FA300DGD

  • Page 1: Table Of Contents

    Propane Construction Heater Description Dyna-Glo Delux Model RMC-FA300DGD heaters are 300,000 BTU/Hr construction heaters. This heater uses propane gas for combustion, and electricity to run the fan. It is primarily intended for temporary heating of well-ventilated buildings under construction, alteration or repair. This heater should be utilized in sheltered, well-ventilated areas, but never in occupied dwellings.
  • Page 2: General Safety Information

    Dyna-Glo Delux Operating Instructions and Parts Manual RMC-FA300DGD Dyna-Glo General Safety Information - Do not use the heater in occupied Follow all local ordinances and codes. dwellings. In the absence of local ordinances (Continued) and codes, refer to ANSI/NFPA 58.
  • Page 3: Theory Of Operation

    Dyna-Glo Delux Operating Instructions and Parts Manual Models RMC-FA300DGD General Safety Information - Use only original replacement parts. SAFETY CONTROL SYSTEM (Continued) This heater must use design-specific This system shuts the heater down if parts. Do not substitute or use generic Minimum heater clearances from the flame is extinguished.
  • Page 4: Ventilation

    Dyna-Glo Delux Operating Instructions and Parts Manual RMC-FA300DGD Dyna-Glo ProFitter & Dyna-Glo Propane Construction Heater Installation Operation Installation Operation Review and under- Review and under- Review and under- Review and under- stand all of the stand all of the stand all of the...
  • Page 5: Operation

    Dyna-Glo Delux Operating Instructions and Parts Manual Model RMC-FA300DGD Operation (Continued) Maintenance Do not adjust the Do not attempt to IMPORTANT: Always remove the fan regulator above 10 service the heater from the motor shaft before removing PSIG or below 7 PSIG, or the heater while it is hot, operating or plugged the motor assembly from the heater.
  • Page 6: Storage

    Dyna-Glo Delux Operating Instructions and Parts Manual RMC-FA300DGD Dyna-Glo ProFitter & Dyna-Glo Propane Construction Heater Maintenance (Continued) IGNITOR 2. Replace the plastic caps over the Maintenance (Continued) IGNITOR 2. Replace the plastic caps over the fittings that were installed when you fittings that were installed when you...
  • Page 7 Dyna-Glo Delux Operating Instructions and Parts Manual RMC-FA300DGD For Repair Parts, call 1-877-447-4768 24 hours a day – 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list...
  • Page 8 RMC-FA300DGD Dyna-Glo Delux Operating Instructions and Parts Manual Model RMC-FA300DGD Repair Parts List for Propane Construction Heater Ref. Part Ref. Part Description Qty. Description Qty. Inner Shell Assembly 2315586 Capacitor 2201586 Screw 2001355 Bushing Strain Relief 2101633 Frame Holder 2315587...
  • Page 9: Troubleshooting Chart

    RMC-FA300DGD Dyna-Glo Delux Operating Instructions and Parts Manual Dyna-Glo ProFitter & Dyna-Glo Propane Construction Heater Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Fan does not turn when 1. No electric power to heater 1. Check current to electric outlet. If voltage is...
  • Page 10: Warranty

    RMC-FA300DGD Dyna-Glo Delux Operating Instructions and Parts Manual LIMITED WARRANTY: This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale. GHP Group, Inc., at it’s option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group, Inc., within one (1) year of retail purchase.
  • Page 11: Warranty Registration

    WARRANTY REGISTRATION IMPORTANT: We urge you to fill out your warranty registration card within fourteen (14) days of date of purchase. You can also register your warranty on the internet at www.ghpgroupinc.com. Complete the entire serial number. Retain this portion of the card for your records.

Table of Contents