  • Page 1 Digital Automatic Blood Pressure Monitor Model MIT Elite • Instruction Manual • Mode d’emploi • Gebrauchsanweisung • Manuale di istruzioni • Manual de instrucciones • Gebruiksaanwijzing • IM-HEM-7300-WE7-03-05/2012 5329377-2D 12D0973...
  • Page 2: Table Of Contents

    Contents Before using the unit Introduction ................3 Important Safety Information ............ 4 1. Overview ................6 2. Preparation ................. 10 2.1 Installing/Replacing the Batteries........10 2.2 Setting the Date and Time ..........12 Operating instructions 3. Using the Unit..............15 3.1 How to Sit Correctly When Taking a Measurement ..
  • Page 3: Introduction

    Introduction Thank you for purchasing the OMRON MIT Elite Upper Arm Blood Pressure Monitor. The OMRON MIT Elite is a fully automatic blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need for pressure pre-setting or re-inflation the device uses its advanced “IntelliSense”...
  • Page 4: Important Safety Information

    Important Safety Information Important Safety Information Consult your doctor during pregnancy, arrhythmia and arteriosclerosis. Please read this section carefully before using the unit. Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. (General Usage) •...
  • Page 5 Important Safety Information • Do not use the AC adapter if the unit or the power cord is damaged. Turn off the power and unplug the power cord immediately. (Battery Usage) • If battery fluid should get on your skin or clothing, immediately rinse with plenty of clean water.
  • Page 6: Overview

    1.Overview 1. Overview Main unit A. Air jack F. Display B. Date/time setting button ( G. Battery compartment C. O/I START button D. Memory button ( E. AC adapter jack (for optional AC adapter)
  • Page 7 1.Overview Arm Cuff H. Arm cuff (Medium cuff: arm circumference 22-32 cm) I. Air tube J. Air plug...
  • Page 8 1.Overview Display K. Systolic blood pressure S. Pulse display L. Diastolic blood pressure T. Date/Time display M. Heartbeat symbol U. Irregular heartbeat symbol 1. Flashes during measurement V. Guest symbol 2. If flashing after measurement complete indicates blood pressure out of recommended range N.
  • Page 9: Package Contents

    1.Overview Package contents W. Storage case • Instruction manual X. Four “AAA” alkaline (LR03) • Guarantee card batteries • Blood pressure pass...
  • Page 10: Preparation

    2.Preparation 2. Preparation Installing/Replacing the Batteries Turn the main unit upside down. Slide the battery cover in the direction of the arrow while pressing the ribbed part of the cover. “ ” Install or replace four size batteries so that the + (positive) and - (negative) polarities match the polarities indicated on the battery compartment.
  • Page 11 2.Preparation Battery Life & Replacement If the battery low symbol ( ) appears on the display, replace all four batteries at the same time. - When the battery low symbol ( ) starts to blink, you will still be able to use the unit for a short while. You should replace the batteries with new ones ahead of time.
  • Page 12: Setting The Date And Time

    2.Preparation Setting the Date and Time Your blood pressure monitor automatically stores up to 90 measurements values with the date and time. To make use of the memory and average values functions: • Set the unit to the correct date and time before taking a measurement for the first time.
  • Page 13 2.Preparation Press the Date/time setting button ) to confirm the setting when the desired number appears on the display. The year is set and the month digits flash on the display. Repeat steps 2 and 3 to set the month. The month is set and the day digits flash on the display.
  • Page 14 2.Preparation Repeat steps 2 and 3 to set the hour. The hour is set and the minutes digits flash on the display. Repeat steps 2 and 3 to set the minutes. The minutes settings is set. Press the Date/time setting button ) to turn the monitor off.
  • Page 15: Using The Unit

    3.Using the Unit 3. Using the Unit How to Sit Correctly When Taking a Measurement You can take a measurement on either your left or right arm. Notes: • Measurements should be taken in a quiet place and you should be in a relaxed, seated position.
  • Page 16 3.Using the Unit Notes: • Correct posture during measurement is necessary to get accurate results. • You should also try to measure your blood pressure at the same time each day. (Within 1 hour after waking up is recommended.) Incorrect Posture •...
  • Page 17: Applying The Arm Cuff

    Omron recommends to always use the same arm for measurement. If the values between the two arms differ substantially, please check with your doctor which arm to use for your measurement.
  • Page 18 3.Using the Unit Put your left arm through the cuff loop. Note: If the cuff is not assembled, pass the end of the cuff furthest from the tubing through the metal D-ring to form a loop. The smooth cloth should be on the inside of the cuff loop.
  • Page 19 3.Using the Unit Position the arm correctly. 1) The air tube should run down the inside of your forearm and be in line with your middle finger. 2) The bottom of the cuff should be approximately 1 to 2 cm above your elbow. 3) Apply the cuff to your upper arm so that the coloured marker (blue...
  • Page 20: Taking A Reading

    3.Using the Unit Taking a Reading Press the O/I START button to turn on the unit. All symbols appear on the display. The cuff starts to inflate automatically. As the cuff inflates, the unit automatically determines your ideal inflation level. This unit detects the pulse during inflation.
  • Page 21 3.Using the Unit Press the O/I START button to turn the unit off. Note: If you forget to turn the monitor off, it will automatically turn off after two minutes. Notes: • Self-diagnosis of measured results and treatment are dangerous. Please follow the instructions of your doctor.
  • Page 22 3.Using the Unit Using the Guest Mode The monitor stores measurement values for one user in the memory. The guest mode can be used to take a single measurement for another user. No measurement values are stored in the memory when the guest mode is selected.
  • Page 23 3.Using the Unit Important: • If your systolic or diastolic pressure is outside the standard range, the heartbeat symbol will blink when the measurement result is displayed. Recent research suggests that the following values can be used as a guide to high blood pressure for measurements taken at home.
  • Page 24 3.Using the Unit What is Irregular Heartbeat? An irregular heartbeat is a Normal Heartbeat heartbeat rhythm that varies by Pulse more than 25% from the average Blood pressure heartbeat rhythm detected while the unit is measuring the systolic Irregular Heartbeat and diastolic blood pressure.
  • Page 25: Using The Memory Function

    3.Using the Unit Using the Memory Function This unit has a memory capable of storing 90 sets of readings. Every time you complete the measurement, the unit automatically stores the blood pressure and pulse rate. If there are three readings within 10 minutes of the last reading, the average of the three readings is displayed.
  • Page 26 3.Using the Unit While the average value is displayed, press the Memory button ) again. The result from the most recent measurement is displayed. The date and time are alternately displayed. Note: If your systolic or diastolic pressure is outside the standard range, the heartbeat symbol will blink when the measurement result is displayed.
  • Page 27 3.Using the Unit Press the Memory button ( repeatedly to cycle through the previous measurement results. Keep the button pressed down to cycle rapidly through the previous results. If the irregular heartbeat symbol was displayed at the time of a measurement, this is displayed when that result is displayed.
  • Page 28: To Delete All The Values Stored In Memory

    3.Using the Unit To Delete All the Values Stored in Memory You cannot delete individual stored readings, all the readings in the unit will be deleted. Press the Memory button ) to turn the monitor on. Press the Memory button ) again.
  • Page 29: Quick Reference Guide

    4.Quick Reference Guide 4. Quick Reference Guide If you are using this device for the first time, please read carefully chapter 3 of this instruction manual. To help ensure a reliable reading, avoid eating, drinking alcohol, smoking, or exercising for at least 30 minutes before taking a measurement.
  • Page 30: Handling Errors And Problems

    5.Handling Errors and Problems 5. Handling Errors and Problems Error Messages Error Display Cause Remedy Repeat measurement. Remain still and do not talk during Movement during measurement. measurement Refer to section 3.3. Insert the air plug securely. Air plug disconnected. Refer to section 3.2.
  • Page 31 5.Handling Errors and Problems Error Display Cause Remedy Contact your OMRON retail outlet or distributor. Device error. Refer to Chapter 8. Note: The irregular heartbeat symbol may also be displayed with error messages.
  • Page 32: Troubleshooting

    5.Handling Errors and Problems Troubleshooting Problem Cause Remedy Apply the arm cuff Arm cuff not applied correctly. correctly. Refer to section 3.2. Remain still and do not talk during Movement or talking The reading is measurement. during measurement. extremely low (or high). Refer to section 3.3.
  • Page 33 (+/ -) polarity. Press the O/I START button and repeat measurement. If the problem continues, try replacing the batteries Other problems. with new ones. If this still does not solve the problem, contact your OMRON retail outlet or distributor.
  • Page 34: Maintenance And Storage

    • Do not use petrol, thinners or similar solvents to clean the arm cuff. • Do not carry out repairs of any kind by yourself. If a defect occurs, consult your OMRON retail outlet or distributor as mentioned on the packaging.
  • Page 35 • Do not carry out any repairs yourself. If a defect occurs or you have doubts about the correct functioning of the device, consult your authorised OMRON dealer or the OMRON Customer Service. Storage Keep the unit in its storage case when not in use.
  • Page 36: Optional Parts

    Large Arm Cuff AC Adapter Arm circumference 22 - 32 cm Arm circumference 32 - 42 cm Adapter-3094298-6 (Model: AC Adapter-E1600) CL-MIT Elite CM1-9997578-9 Note: Q Adapter-1098336-8 and 9999358-2 R Adapter-9997605-0 Note: CL1 cuff cannot be cannot be used for this used for this device.
  • Page 37: Technical Data

    Supplementary requirements for electromechanical blood pressure measuring systems. • This OMRON product is produced under the strict quality system of OMRON HEALTHCARE Co. Ltd., Japan. The Core component for OMRON blood pressure monitors, which is the Pressure Sensor, is produced in Japan.
  • Page 38 This medical device manufactured by OMRON HEALTHCARE conforms to this EN60601-1-2:2007 standard for both immunity and emissions. Nevertheless, special precautions need to be observed: Do not use mobile (cellular) telephones and other devices, which generate strong electrical or electromagnetic fields, near the medical device.
  • Page 39: Some Useful Information About Blood Pressure

    9.Some Useful Information about Blood Pressure 9. Some Useful Information about Blood Pressure What is Blood Pressure? Blood pressure is a measure of the force of blood flowing against the walls of the arteries. Arterial blood pressure is constantly changing during the course of the heart’s cycle.
  • Page 40 9.Some Useful Information about Blood Pressure Upper curve: systolic blood pressure Lower curve: diastolic blood pressure Time of day Example: fluctuation within a day (male, 35 years old) Classification of Blood Pressure by the World Heath Organization The World Health Organization (WHO) and the International Society of Hypertension (ISH) developed the Blood Pressure Classification shown in this figure.
  • Page 41 9.Some Useful Information about Blood Pressure...
  • Page 42 9.Some Useful Information about Blood Pressure Manufacturer OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN EU-representative OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www.omron-healthcare.com OMRON (DALIAN) CO., LTD. Production facility Dalian, CHINA OMRON HEALTHCARE UK LTD.