I
USER'S INFORMATION
MANUAL
MODELS:
33" Multi-position Gas Furnaces
(Manufactured Housing or Modular Home Applications)
I_~~--~-~~~~~-~~-~~~~~
SAFETY
INSTRUCTIONS FOR EXAMINING THE
FURNACE INSTALLATION
START-UP AND SHUTDOWN INSTRUCTIONS
HOW YOUR GAS FURNACE WORKS
OPERATING INSTRUCTIONS
TO TURN OFF THE APPLIANCE
FURNACE MAINTENANCE - USER INFORMATION
EXTERNAL AIR FILTERS
How to Clean your Filter
Removing Filters For Manufactured (Mobile) Home And Modular
Home Installations Using A Return Air Duct System And Plenum
CONTACT INFORMATION FOR USA
.
Contact us by mail:
DISTRIBUTED BY:
StyleCrest
801 W. 37th Street
Building #7
Wichita, Ks 67219
We recommend that the user read all sections of this
manual and keep the manual for future reference.
rAWARNINGl
FIRE OR EXPLOSION HAZARD • Failure to follow safety warnings
exactly could result in serious injury, death, or property damage.
Do not store or use gasoline
liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone (includ-
ing cell phone) in your building.
Leave the building immediately.
Immediately call your gas supplier from a neighbor's phone. Fol-
low the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation
and service must be performed
installer, service agency or the gas supplier.
SECTION I: SAFETY
I
I
A
This is a safety alert symbol. When you see this symbol on
~_
!abels or in manuals, be alert to the potential for personal
mjury,
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently
avoided, will result in death or serious injurv.
TABLE OF CONTENTS
.
Manufacturer:
Johnson
Controls
Unitary Products
or other flammable
vapors and
by a qualified
hazardous situation, which, if not
1
Removing Filters For Manufactured (Mobile) Home
And Modular Home Installations Without A Return
2
Air Duct System And Plenum
2
BLOWER CARE
3
MOTOR LUBRICATION
3
SERVICE INFORMATION
3
TROUBLESHOOTING
PROBLEMS
4
FURNACE CONTROL DIAGNOSTICS
4
FURNACE MAINTENANCE - DEALERICONTACTOR
4
REPLACEMENT PARTS LIST
WIRING DIAGRAM
4
LIMITED WARRANTY
CONTACT INFORMATION FOR CANADA
.
Go to website at
www.york.com
"contact form" and follow the instructions.
.
Contact us by mail:
Johnson
Consumer
Norman, OK 73069
WARNING indicates a potentially
avoided, could result in death or serious injurv.
CAUTION
indicates a potentially hazardous situation, which, if not
avoided may result
in minor or moderate
alert against unsafe practices and hazards involving only property dam-
age.
1.
The furnace area must be kept clear and free of combustible mate-
rials, gasoline and other flammable vapors and liquids.
2.
Insulating materials may be combustible. The furnace must be
kept free and clear of insulating materials. The furnace area must
be examined when installed in an attic or other insulated space or
when insulation is added to be sure that the insulation material has
been kept away from the furnace.
3.
The furnace needs air for combustion in order to operate properly
and safely. Do not block or obstruct air openings on the furnace,
air openings to the area where the furnace is installed, or spaces
around the furnace.
4.
Follow the instructions exactly as shown on the OPERATING
INSTRUCTION
LABEL on the furnace or the "START-UP AND
SHUTDOWN INSTRUCTIONS" section of this manual when light-
ing the furnace or turning the furnace off.
5.
Should the gas supply fail to shut off or if overheating occurs, shut
off the gas valve to the furnace before shutting off the electrical
supply.
6.
Do not use this furnace if any part has been under water. A flood-
damaged furnace is extremely dangerous. Attempts to use the fur-
nace can result in fire or explosion. A qualified service agency
should be contacted to inspect the furnace and replace all gas
controls, control system parts, electrical parts that have been wet
or the furnace if deemed necessary.
G
•• ,..a
lfHCllHC't'
CUH'HlO
ama
(~
~
"'''Jl,
I.:lA;r;~'"
1509001
Certified Quality
Management System
click on "contact", then click on
Controls
Unitary Products
Relations
5005 York Drive
hazardous situation, which, if not
injurv. It is also used to
420706-UUM-A-1008
4
.4
5
5
5
5
5
5
5
6

Advertisement

loading

Summary of Contents for Coleman 33"

  • Page 1 USER'S INFORMATION •• ,..a lfHCllHC't' CUH'HlO MANUAL "'''Jl, MODELS: I.:lA;r;~'" 1509001 Certified Quality 33" Multi-position Gas Furnaces Management System (Manufactured Housing or Modular Home Applications) I_~~--~-~~~~~-~~-~~~~~ TABLE OF CONTENTS SAFETY Removing Filters For Manufactured (Mobile) Home INSTRUCTIONS FOR EXAMINING THE And Modular Home Installations Without A Return FURNACE INSTALLATION Air Duct System And Plenum...
  • Page 2: Start-Up And Shutdown Instructions

    Examine the vent pipe making sure it is firmly in place, that it slopes slightly upward and is physically sound without holes and all of the connections are secure. Johnson Controls Unitary Products...
  • Page 3: How Your Gas Furnace Works

    If you don't smell gas, go to next step. To Gas Supply To Gas Supply Ground Union Ground Union Valve Ground Pipe Union Ground Union Valve Pipe Downflow Upflow Configuration Configuration FIGURE 4: Upflow/Downflow Gas Piping Johnson Controls Unitary Products...
  • Page 4: Furnace Maintenance - User Information

    Figure 5. when the furnace blower access panel/door is removed. As a safety precaution, all electrical power and the gas supply to the furnace should be turned off before servicing. Johnson Controls Unitary Products...
  • Page 5: Motor Lubrication

    1/4 second and "off" for 1/4 second. This pattern will be repeated the number of times equal to the code. For example, six "on" flashes equals a number 6 fault code. All flash code sequences are broken by a 2 sec- ond "off" period. Johnson Controls Unitary Products...
  • Page 6: Limited Warranty

    Unitary Products Group (UPG) Customer Relations Department, PO Box 19014, Wichita, KS 67204-9014. 420706-UU M-A-1 008 SUbject to change without notice. Printed in U.S.A. Supersedes: Nothing Copyright © 2008 by Johnson Controls, Inc. All rights reserved. Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069...

This manual is also suitable for:

Mg9s