Omron Comp A-I-R NE-C801KD Instruction Manual

Compressor nebulizer
Hide thumbs Also See for Comp A-I-R NE-C801KD:

Advertisement

Quick Links

NE-C801S-KDAP(V)_A_M03_130723.pdf
NE-C801S-KDAP(V)_A_M.book Page 1 Tuesday, July 23, 2013 12:23 PM
TM
Compressor Nebulizer
NE-C801KD
Model

Instruction Manual

NE-C801S-KDAP(V)_06/2013
1887047-3A

Advertisement

Table of Contents
loading

Summary of Contents for Omron Comp A-I-R NE-C801KD

  • Page 1: Instruction Manual

    NE-C801S-KDAP(V)_A_M03_130723.pdf NE-C801S-KDAP(V)_A_M.book Page 1 Tuesday, July 23, 2013 12:23 PM Compressor Nebulizer NE-C801KD Model Instruction Manual NE-C801S-KDAP(V)_06/2013 1887047-3A...
  • Page 2 NE-C801S-KDAP(V)_A_M.book Page 2 Tuesday, July 23, 2013 12:23 PM QUICK MANUAL Please read entire manual before using the device. Warning: Clean and disinfect all the parts before using them. page 16-18 1. Adding medication Rotate the inhalation top anti- clockwise to remove. Add the appropriate amount of prescribed medication.
  • Page 3: Connecting Ac Adapter

    NE-C801S-KDAP(V)_A_M.book Page 3 Tuesday, July 23, 2013 12:23 PM 3. Connecting AC adapter Power Outlet Power Plug Power Connector Insert the power plug of AC Plug the AC adapter into adapter into the power the power outlet. connector of the main unit. page 11 4.
  • Page 4: Table Of Contents

    This is a medical device. Operate the device only as instructed by your doctor and/or respiratory therapist. NE-C801KD includes the kids accessories to enable children to feel more comfortable while inhaling. It improves compliance with drug treatment. How the nebulizer kit works...
  • Page 5: Intended Use

    • Caregiver or patient under the guidance of qualified medical experts for home treatment. • The user should also be capable of understanding general operation of NE-C801KD and the content of instruction manual. Intended Patients This product should not be used on patients, who are unconscious or are not breathing spontaneously.
  • Page 6: Important Safety Instructions

    • Do not immerse the compressor in water or other liquid. • Do not use or store the device in humid locations, such as a bathroom. • Use only original OMRON AC adapter. Use of unsupported AC adapter may damage the device.
  • Page 7 NE-C801S-KDAP(V)_A_M.book Page 7 Tuesday, July 23, 2013 12:23 PM Important safety instructions - if more than one person uses the same device • Be sure to wash or wipe the parts after use, and ensure that they are thoroughly disinfected and dried, and stored in a clean location. •...
  • Page 8 • Do not misuse the cord of the AC adapter. • Do not wind the cord of the AC adapter around the compressor or AC adapter. • Changes or modifications not approved by OMRON HEALTHCARE will void the user warranty.
  • Page 9: Know Your Unit

    NE-C801S-KDAP(V)_A_M.book Page 9 Tuesday, July 23, 2013 12:23 PM 1. Know your unit Nebulizer Kit Compressor (Main Unit) Nebulizer Kit Holder Air Tube Plug Air Tube Connector Air Tube Plug Power Switch Rear View Air Tube Air Filter Cover Power *Air filter inside Connector Nebulizer Kit...
  • Page 10 NE-C801S-KDAP(V)_A_M.book Page 10 Tuesday, July 23, 2013 12:23 PM 1. Know your unit Accessories Mouthpiece Child Mask (PVC) Infant Mask (PVC) Spare Air Filters × 5 AC adapter Carrying Bag Instruction Manual Compressor Nebulizer NE-C801KD Model Instruction Manual NE-C801S-KDAP(V)_06/2013 1887047-3A...
  • Page 11: Operating Instructions

    NE-C801S-KDAP(V)_A_M.book Page 11 Tuesday, July 23, 2013 12:23 PM Operating instructions 2. Preparing the nebulizer for use Warning: Clean and disinfect the nebulizer kit, kids accessory, mask, mouthpiece or nosepiece before using them when as follows: - the first time after purchase. - if the device has not been used for a long period of time - if more than one person uses the same device For directions on cleaning and disinfecting refer to Section 4 (page 16-18).
  • Page 12: Adding Medication And Assembling The Parts

    NE-C801S-KDAP(V)_A_M.book Page 12 Tuesday, July 23, 2013 12:23 PM 2. Preparing the nebulizer for use Adding medication and assembling the parts Remove the mask or mouthpiece, kids accessory and cap from the nebulizer kit. Remove the inhalation top from the medication tank. Rotate the inhalation top anti-clockwise.
  • Page 13 NE-C801S-KDAP(V)_A_M.book Page 13 Tuesday, July 23, 2013 12:23 PM 2. Preparing the nebulizer for use Attach the cap, kids accessory, mask or mouthpiece to the nebulizer kit. Attach the cap to the inhalation air inlet. Attach the kids accessory to the inhalation top. Attach the mask or mouthpiece to the inhalation top.
  • Page 14: Taking Medication

    NE-C801S-KDAP(V)_A_M.book Page 14 Tuesday, July 23, 2013 12:23 PM 3. Taking medication Hold the nebulizer kit as indicated on the right. Caution: Do not tilt the nebulizer kit at an angle of greater than 45° in all directions. Medication may flow into the mouth or it may result in not nebulizing effectively.
  • Page 15 NE-C801S-KDAP(V)_A_M.book Page 15 Tuesday, July 23, 2013 12:23 PM 3. Taking medication When treatment is complete, turn the power off. Check that there is no condensation or moisture in the air tube and unplug the device from the power outlet. Warning: Condensation may occur in the air tube.
  • Page 16: Care And Maintenance

    NE-C801S-KDAP(V)_A_M.book Page 16 Tuesday, July 23, 2013 12:23 PM Care and maintenance 4. Cleaning and disinfecting Cleaning Clean the parts after each use to remove residual medication. This will avoid inefficient nebulization or infection. ■ Washable parts • Nebulizer Kit (Inhalation top, Medication tank), Kids accessory, Mask, Mouthpiece, Nosepiece Wash them in warm water and mild detergent (neutral detergent).
  • Page 17: Disinfecting

    NE-C801S-KDAP(V)_A_M.book Page 17 Tuesday, July 23, 2013 12:23 PM 4. Cleaning and disinfecting Disinfecting Always disinfect the parts after the last treatment of the day. If the parts are heavily stained, replace them with new ones. To select a method for disinfection, refer to the table on page 18. Caution: Do not use an autoclave, EOG gas sterilizer or low temperature plasma sterilizer.
  • Page 18 NE-C801S-KDAP(V)_A_M.book Page 18 Tuesday, July 23, 2013 12:23 PM 4. Cleaning and disinfecting : applicable : not applicable Parts Disinfecting method Materials Alcohol Disinfecting ethanol Sodium hypochlorite Milton* (0.1%, 15min.) Quaternary ammonium Osvan* (0.1%, 10min.) Chlorhexidine Hibitane* (0.5%, 30min.) Amphoteric Surfactant Tego 51* (0.2%, 15min.)
  • Page 19: Maintenance And Storage

    NE-C801S-KDAP(V)_A_M.book Page 19 Tuesday, July 23, 2013 12:23 PM 5. Maintenance and storage To keep your device in the best condition and protect the device from damage follow these directions: Caution: • Do not leave the device unattended with infants or persons who cannot express their consent. •...
  • Page 20: Changing The Air Filter

    Notes: • Use only OMRON air filters designed for this device. Do not operate without a filter. • There is no front or back orientation for the air filters. • Check that air filters are clean and free of dust before inserting them.
  • Page 21: Troubleshooting

    40 minute minutes? interval before using the device again. Note: If the suggested remedy does not solve the problem, do not try to repair the device - no parts of the unit are user serviceable. Please contact an authorized OMRON distributor.
  • Page 22: Technical Data

    Notes: • Subject to technical modification without prior notice. • This OMRON product is produced under the strict quality system of OMRON HEALTHCARE Co., Ltd., Japan. • The device may not work if the temperature and voltage conditions are different to those defined in the specifications.
  • Page 23 NE-C801S-KDAP(V)_A_M.book Page 23 Tuesday, July 23, 2013 12:23 PM 8. Technical data Technical data for the OMRON NE-C801KD Compressor with the OMRON V.V.T. (Virtual Valve Technology) Nebulizer kit: Particle Size: **MMAD Approx. 3µm MMAD = Mass Median Aerodynamic Diameter Medication Tank Capacity:...
  • Page 24 This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices. This medical device manufactured by OMRON HEALTHCARE conforms to this EN60601-1-2:2007 standard for both immunity and emissions. Nevertheless, special precautions need to be observed: •...
  • Page 25: Optional Parts And Accessories

    NE-C801S-KDAP(V)_A_M.book Page 25 Tuesday, July 23, 2013 12:23 PM 9. Optional parts and accessories V.V.T. Nebulizer Kit N-01 & V.V.T. Nebulizer Kit N-01 & V.V.T. Nebulizer Kit N-01 & Mouthpiece Set Smile Bear Set Happy Bunny Set Model: NEB-NSET3-81E Model: NEB-NKKD1-81E Model: NEB-NKKD2-81E Mouthpiece Nebulizer Kit No.
  • Page 26 NE-C801S-KDAP(V)_A_M.book Page 26 Tuesday, July 23, 2013 12:23 PM Notes...
  • Page 27 OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp THE NETHERLANDS OMRON HEALTHCARE SINGAPORE PTE LTD. 438A Alexandra Road, #05-05/08 Asia Pacific HQ Alexandra Technopark, Singapore 119967 www.omron-healthcare.com.sg OMRON HEALTHCARE MANUFACTURING VIETNAM CO., LTD. Production facility Binh Duong Province, VIETNAM...