Download Print this page
Hamilton Beach 4160 Instructions Manual

Hamilton Beach 4160 Instructions Manual

Hide thumbs Also See for 4160:

Advertisement

Air Purifier
Air Purifier Safety.......................... 2
Know Your Air Purifier .................. 5
How to Clean................................ 12
Troubleshooting Guide.............. 17
Customer Service ........................ 18
In USA: 1-800-851-8900
840071100

Advertisement

loading

Summary of Contents for Hamilton Beach 4160

  • Page 1: Table Of Contents

    Air Purifier Air Purifier Safety......2 Know Your Air Purifier ....5 How to Assemble and Use.... 6 How to Clean........ 12 Troubleshooting Guide....17 Customer Service ......18 In USA: 1-800-851-8900 In Canada: 1-800-267-2826 840071100...
  • Page 2: Air Purifier Safety

    Shock, fire, or bodily injury if the intake or outlet grilles are removed. may occur. Contact Hamilton Beach DO NOT attempt to defeat or override at 1-800-851-8900 for assistance. this safety feature.
  • Page 3 • Always unplug unit before cleaning, servicing or replacing the UV bulb. • Never look directly at UV bulb or place face directly on outlet grille. • Use only Hamilton Beach replacement UV bulb: Part No. 04810. • Read all instructions before using.
  • Page 4 To Order Replacement Parts Replacement bulbs may be available where the air purifier was purchased or can be obtained directly from Hamilton Beach. Purifier Control Room Size* Carbon...
  • Page 5: Know Your Air Purifier

    Know Your Air Purifier Parts and Features 1. Outlet Grille 6. UV Bulb Check Window (not shown – see page 8 for location) 2. Ultraviolet (UV) Bulb 7. Filter Check Gauge 3. Control Panel 8. Air Sensor Cleaner* 4. AirSmart ™...
  • Page 6: How To Assemble And Use

    How to Assemble and Use IMPORTANT: Your Hamilton Beach air purifier is designed for easy use and maintenance. Make sure that the UV bulb, HEPA filter, and carbon pre-filter are properly installed before use. Before First Use Be sure to remove all packing materials.
  • Page 7 Installing the Carbon Pre-Filter NOTE: The carbon pre-filter should be replaced approximately every three months. Remove the intake grille by carefully pulling the upper two side tabs away from the body of the air purifier and lifting up. Locate the black carbon pre-filter. It will be folded inside a plastic bag.
  • Page 8 Installing the UV Bulb Open and remove the outlet grille by pulling up on the handle on the upper back of the air purifier. Remove the packaged UV bulb from inside the air purifier. Be careful not to touch the glass part of bulb. Handle by metal ends only.
  • Page 9 Installing the UV Bulb (continued) Once the ends of the bulb are completely inserted into the socket, rotate the bulb a quarter turn until it locks into place. Insert the two center tabs on the front of the outlet grille into the middle slots on the front of the opening.
  • Page 10 Plugging in the Air Purifier WARNING: To reduce the risk of NOTE: The polarized plug will only electrical shock, never plug in the air fit in one direction—DO NOT try purifier while your hands are wet. to force the plug. If you are unable to Always unplug the air purifier before insert the plug into the outlet, try moving or servicing the unit.
  • Page 11 Setting the Controls – AirSmart ™ Models 1. Germicidal UV Button – Turns on The Display also has check marks the germicidal UV lamp to reduce that will appear to indicate that it is harmful bacteria from the filtered air. time to check the carbon pre-filter or When this button is on, a bluish glow HEPA filter.
  • Page 12: How To Clean

    How to Clean Your air purifier is designed to provide years of trouble-free service with minimal maintenance. The following instructions will help you maximize the life and efficiency of your air purifier. wWARNING To reduce risk of electric shock: • Always unplug before cleaning. •...
  • Page 13 Checking the Filters A special filter check gauge is included The carbon pre-filter will last with your air purifier to allow you to approximately three months. check the condition of the filters. It is NOTE: You must reinstall and snap stored in a compartment behind the the intake grille before checking the front intake grille.
  • Page 14: Replacing The Hepa Filter

    Replacing the HEPA Filter The HEPA filter will normally last about If the filter check gauge indicates that 12 months before it must be replaced, the filter requires replacement, it is or approximately every fourth time the recommended that you first replace carbon pre-filter is replaced.
  • Page 15 For maximum germicidal protection, from Hamilton Beach. replace the UV bulb when replacing the HEPA filter, or if the UV bulb To Remove the UV Bulb: Turn off and unplug the air purifier.
  • Page 16 Replacing the UV Starter If the UV bulb does not light after installing a new bulb, the starter should be replaced. See page 4 for replacement parts. Turn off and unplug air purifier. Remove the intake grille and filters. The starter is the small cylinder-shaped Starter part located behind the filter.
  • Page 17: Troubleshooting Guide

    Troubleshooting Guide The following section provides the solutions to many common problems and questions. If your air purifier is not working correctly, review these solutions first. If your problem is still not solved after reviewing this guide, call our toll-free customer service number, listed on the front cover of this manual, for assistance.
  • Page 18: Customer Service

    SERIES: _________________ THREE-YEAR LIMITED WARRANTY Hamilton Beach/Proctor-Silex, Inc. warrants this appliance to be free from defects in material and workmanship for a period of three (3) years from the date of original purchase, except as noted. There is no warranty with respect to the following, which may be supplied with this appliance: carbon pre-filter, HEPA filter, UV germicidal bulb, or starter.

This manual is also suitable for: