Lincoln Electric POWER WAVE S350 CE Operator's Manual

Power wave
Hide thumbs Also See for POWER WAVE S350 CE:

Advertisement

Quick Links

IM2034
05/2010
Rev. 0
POWER WAVE S350 CE
OPERATOR'S MANUAL
ENGLISH
THE LINCOLN ELECTRIC COMPANY
22801 St. Clair Ave., Cleveland Ohio 44117-1199 USA
www.lincolnelectric.eu

Advertisement

Table of Contents
loading

Summary of Contents for Lincoln Electric POWER WAVE S350 CE

  • Page 1 IM2034 05/2010 Rev. 0 POWER WAVE S350 CE OPERATOR’S MANUAL ENGLISH THE LINCOLN ELECTRIC COMPANY 22801 St. Clair Ave., Cleveland Ohio 44117-1199 USA www.lincolnelectric.eu...
  • Page 2: The Lincoln Electric Company

    Address: c/o Balmes, 89 - 80 2a 08008 Barcelona SPAIN Hereby declare that welding equipment: Power Wave S350 CE, including options and accessories STT Module Sales code: K2823, code may also contain prefixes and suffixes K2921, code may also contain prefixes and suffixes...
  • Page 3: Table Of Contents

    12/05 THANKS! For having choosen the QUALITY of the Lincoln Electric products. • Please Examine Package and Equipment for Damage. Claims for material damaged in shipment must be notified immediately to the dealer. • For future reference record in the table below your equipment identification information. Model Name, Code &...
  • Page 4: Safety

    Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or damage to this equipment. Read and understand the following explanations of the warning symbols. Lincoln Electric is not responsible for damages caused by improper installation, improper care or abnormal operation.
  • Page 5: Installation And Operator Instructions

    ® The POWER WAVE S350 CE is rated at 300 amps at • Dirt and dust that can be drawn into the machine 29 volts with a 100% duty cycle. It is further rated to should be kept to a minimum.
  • Page 6: Product Description

    Industrial, Scientific and Medical (ISM) group 2, class in difficult environments. ® A. The POWER WAVE S350 CE is for industrial use • Ethernet connectivity – allows access to the Power only (see Electromagnetic Compatibility EMC Safety Wave utilities software tools.
  • Page 7: Case Front Controls

    WARNING If the auto sense lead feature is disabled and remote voltage sensing is enabled but the sense leads are missing, improperly connected extremely high welding outputs may occur. While most applications perform adequately by sensing the work voltage directly at the output stud, the use of a remote work voltage sense lead is recommended for optimal performance.
  • Page 8: Definition Of Welding Modes

    For a more complete description of the weld modes programmed into the Power Wave S350 CE at the factory, refer to the Weld Set Reference Guide supplied with the machine or available at www.powerwavesoftware.com.
  • Page 9: Constant Voltage Welding

    or to the higher range (positive numeric values) for a predicted when all the pulsing waveform parameters are crisp and more penetrating arc. known. Using a preset voltage becomes impractical and instead the arc length is set by adjusting “trim”. Trim Normally, when welding with cellulosic types of adjusts the arc length and ranges from 0.50 to 1.50 with electrodes (E6010, E7010, E6011), a higher energy arc...
  • Page 10: Electromagnetic Compatibility (Emc)

    Lincoln Electric. Before installing the machine, the operator must check the work area for any devices that may malfunction because of electromagnetic disturbances.
  • Page 11: Technical Specifications

    12/05 Part List reading instructions • Do not use this part list for a machine if its code number is not listed. Contact the Lincoln Electric Service Department for any code number not listed. • Use the illustration of assembly page and the table below to determine where the part is located for your particular code machine.
  • Page 12: Electrical Schematic

    Electrical Schematic Refer to the "Spare Part" manual supplied with the machine. Accessories Item number Description K14072-1 LF-45 K14083-1 LF-45S K14085-1 CART POWER WAVE S CE K14050-1 Coolarc-50 K10420-1 Coolant Acorox (2x5L) K2921-1 STT module CE K10095-1-15M Remote control 6-pins, 15m K870 Foot Amptrol K2909-1...
  • Page 13: Power Wave

    Spare Parts ® POWER WAVE S350CE - Illustration of Sub-Assemblies ® POWERWAVE S350CE ASSEMBLY PAGE NAME CODE NO.: K NO.: FIGURE NO.: 11625 K2823-2 POWER WAVE® S350 CE English English...
  • Page 14 Item Description Part Number Q-ty M15479 Twist Mate Cable Plug G6094 Wiring Harness (Primary) S24992-7 Input Power Cord S28365 Cooler Jumper Harness M19969-2 Ethernet Patch Cable Fig. A Fig.A : Case Front Assembly (1) Item Description Part Number Q-ty Case Front Assembly (G6519-1) Case Front G6513-1 P.C.
  • Page 15 Fig. B Fig. C Fig.B : Base & Power Conversion Assembly (2) Item Description Part Number Q-ty Base Assembly, (G6520-1) Base L15067-1 Base Extrusion M21251-2 Attachment Kit Bracket L15091 Mounting Foot S28070 Input Choke M22462 Choke Mounting Bracket M22464 Corner Cap L13138 Power Board Bracket M21469-3...
  • Page 16 Fig. D Fig. E Fig.D : Output Choke Assembly (4) Item Description Part Number Q-ty Output Choke Assembly L13270-3 Bottom Choke Bracket M21472-3 Bottom Choke Bracket XS28371 Current Transducer S18504-10 Spacer Washer S25781-2 Spacer T14605 Output Choke S26801-2 Top Choke Bracket M21471-3 Heatsink Holder S22168...
  • Page 17 Fig. F Fig.F : Roof Assembly (6) Item Description Part Number Q-ty Roof Assembly M22129-3 Roof L12763-1 Thread Forming Screw (Not Shown) S9225-99 Horizontal Divider Panel M22375 Horizontal Divider Panel L15068-2 Top Extrusion M21251-1 Bracket L15070 Handle G6525-1 Corner Cap L13138 Left Case Side Assembly M22191-1...
  • Page 18 Diagrams / Schemat poł cze English English...