Weak Or Surging Jets - Jacuzzi Premium J-325 Troubleshooting Manual

Standard troubleshooting approach
Table of Contents

Advertisement

8.8 Weak Or Surging Jets

Weak or surging jets are usually caused by an insuffi cient water supply to the pump or
a clogged or broken impeller. The water level may simply be too low, or there may be an
obstruction in the water fl ow path to the pump or in the pump's impeller. Before making
a service call, ask the customer to verify that all jets are open and that there is suffi cient water in the
hot tub.
Suggested Spare Parts (Page 59): Filter, pump.
Standard Troubleshooting Approach
Is water level
OK?
Yes
Are filter cartridges
clogged or dirty?
Yes
Clean or replace
filter cartridges.
Adjust water
No
level.
Are the filters installed
No
correctly?
Yes
Take pump housing
apart. Is debris
present in pump
impeller? Is the
impeller broken?
Yes
Remove debris or
replace broken
impeller
Fix filter installation
No
problem.
Is there debris or a
loose foreign object
between the filters
No
and pump input?
Yes
Remove debris or
loose foreign object.
40
If pump suction line is
clear, check for
blockage in plumbing
No
on the return side of
pump. Call Jacuzzi
Premium Technical
Support for assistance
in performing this
verification step.