Power Requirements - Jacuzzi J - 480 Owner's Manual

J-400 collection
Table of Contents

Advertisement

J-400
7.0

Power requirements

Jacuzzi ® spas are designed to provide optimum performance and
flexibility of use when connected to their maximum electrical service.
They are configured at the factory. The most common electrical
connections are listed below:
all north american 60 Hz models only:
50A logic. If you prefer, your qualified technician can perform a logic
modification that allows the spas to operate on a different electrical
service (see table footnotes below).
north american J-460/J-465/J-470/J-480 models (60 Hz)
Voltage:
Max. Current Draw:
Frequency:
Number of Wires:
Circuit Breaker (2-Pole):
In 30A configuration, the heater will not operate while either jets
*
pump is running.
** In 50A configuration, the heater will not operate while both jet
pumps are running. This is the factory setting.
*** In 60A configuration the heater will operate while both jet pumps
are running.
all export 50 Hz models:
requiring 2 circuit breakers and only have one logic option available.
export J-460/J-465/J-470/J-480 models (50 Hz)
Voltage:
Max. Current Draw:
Wattage
Frequency:
Number of Wires:
The main terminal breaker is solely for the pumps, circulation
*
pump, ozone, stereo option (if installed) and accessories.
** The heater breaker is solely for the heater, to allow the heater to
operate while both jet pumps are running.
note: Two breakers needed see Figure e page 15.
Page 16
These models come set for
240 VAC
240 VAC
23A
60 Hz
3
30A*
These models have two terminals
Main
Terminal Breaker*
230 VAC
16.6A
3.8 kW
50 Hz
3
240 VAC
36A
60 Hz
60 Hz
3
50A**
60A***
Heater
Terminal Breaker**
230 VAC
12A
2.6 kW
50 Hz
3
45A
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

J-460J-470J-465

Table of Contents