PERFORMANCE/CAPABILITIES
OPERATING CAPACITY (RACKS/HOUR)
RACKS PER HOUR
DISHES PER HOUR
GLASSES PER HOUR
OPERATING CYCLE (SECONDS)
WASH TIME
DRAIN TIME
RINSE TIME
TOTAL CYCLE TIME (MINUTES)
5 MINUTE TIMER OPERATING CYCLE (SECONDS)
WASH TIME
DRAIN TIME
RINSE TIME
TOTAL CYCLE TIME (MINUTES)
TANK CAPACITY (LITERS) (GALLONS)
WASH TANK
RINSE TANK
TEMPERATURES
WASH--- (MINIMUM)
RINSE---(MINIMUM)
WATER REQUIREMENTS
INLET TEMPERATURE
(40°F Rise Booster Heater)
INLET TEMPERATURE
(70°F Rise Booster Heater)
INLET TEMPERATURE (JPX-300HN)
WATER LINE SIZE I.P.S. (MINIMUM)
DRAIN LINE SIZE I.P.S. (MINIMUM)
FLOW PRESSURE P.S.I.
SECTION 1: SPECIFICATION INFORMATION
SPECIFICATIONS of the JPX-300H/JPX-300HC/JPX-300HN
30
600
600
82
28
10
2
262
28
10
5
(21.5) 5.65
(11.4) 3
(65.6°C) 150°F
(82.2°C) 180°F
(60°C) 140°F
(43.3°C) 110°F
(82.2°C)180°F
1/2"
1 1/2"
20 ±5
JPX-300 Installation/Operation Manual 7610-002-71-26 Rev. J
Issued: 03-09-2006 Revised: N/A
ELECTRICAL REQUIREMENTS
WASH MOTOR HP
NOTE: Typical Electrical Circuit is based upon (1) 125% of the
full amperage load of the machine and (2) typical fixed-trip cir-
cuit breaker sizes as listed in the NEC 2002 Edition. Local
codes may require more stringent protection than what is dis-
played here. Always verify with your electrical service con-
tractor that your circuit protection is adequate and meets all
applicable national and local codes. These numbers are pro-
vided in this manual simply for reference and may change
without notice at any given time.
JPX-300H/JPX-300HC:
VOLTS
PH
HZ
208
1
50
208
1
50
230
1
50
230
1
50
208
1
60
208
1
60
230
1
60
230
1
60
460
3
60
460
3
60
JPX-300HN:
VOLTS
PH
HZ
208
1
50
230
1
50
115
1
60
208
1
60
230
1
60
NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided on
this page is for reference only and may be subject to change
without notice.
2
RINSE
HEATER
TOTAL
RATINGS
AMPS
8.2KW @ 230V
40 A
10KW @ 230V
47 A
8.2KW @ 230V
47 A
10KW @ 230V
51 A
8.2KW @ 230V
39 A
10KW @ 230V
42 A
8.2KW @ 230V
46 A
10KW @ 230V
50 A
8.2KW@480V
11 A
10KW @480V
14 A
RINSE
HEATER
TOTAL
RATINGS
AMPS
N/A
12 A
N/A
12 A
N/A
24 A
N/A
11 A
N/A
12 A
3/4
TYPICAL
ELECTRICAL
CIRCUIT
50 AMP
60 AMP
60 AMP
70 AMP
50 AMP
60 AMP
60 AMP
70 AMP
15 AMP
20 AMP
TYPICAL
ELECTRICAL
CIRCUIT
15 AMP
15 AMP
30 AMP
15 AMP
15 AMP