Download Print this page

Omega FPD1000-HP Series User Manual

High pressure positive displacement flowmeters

Advertisement

Quick Links

FPD1000-HP SERIES
HIGH PRESSURE
Positive Displacement Flowmeters

Advertisement

loading

Summary of Contents for Omega FPD1000-HP Series

  • Page 1 FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters...
  • Page 3: Installation

    To the owner: Thank you for purchasing an OMEGA FPD Series Flowmeter. Please take a few min- utes to read through the manual before in- stalling and operating your meter. If you have any problems with the meter, refer to the Maintenance and Troubleshooting sec- tions of the manual.
  • Page 4: Maintenance

    Reed Relay Specifications • Two wire SPST N/O. • Switching voltage 150 VDC; maximum current 0.25 Amps. • Rating 3 watts. • Duty cycle 20% ON, 80% OFF. Reed Switch Wiring Details (HP Models Only) MAINTENANCE Disassembly: 1. Ensure the fluid supply to the meter has been disconnected, and the line pres- sure has been released before disas- sembly.
  • Page 5: Troubleshooting

    TROUBLESHOOTING Symptom Probable Cause FLUID WILL NOT 1. Foreign matter blocking FLOW THROUGH rotors THE METER 2. Line strainer blocked 3. Damaged rotors 4. Meter connections over- tightened REDUCED FLOW 1. Line strainer partially THROUGH THE blocked METER 2. Fluid is too viscous METER READING 1.
  • Page 6 DISPLAY PARTS LISTING u = Recommended Spare Parts to stock. Bold Text = Indicates Stainless Steel model parts. Item Rec. Qty. Parts (Order from this column only) Reed Switch & Hall Effect are unavailable without meter cap. Model: FPD1202-HP TERMINAL BLOCK Part or Set Part Description...
  • Page 7: Specifications

    SPECIFICATIONS Flow Ranges (LPM or GPM) Above 5 centipoise Below 5 centipoise Accuracy of Reading Maximum Viscosity Maximum Operating Pressure Maximum Operating Temperature Pulse Type Pulses per Litre/Gallons Meter Dimensions Weight Pulse Meter Models 2 to 100 / 0.53 to 26.4 5 to 100 / 1.32 to 26.4 ±...
  • Page 8 DISPLAY PARTS LISTING u = Recommended Spare Parts to stock. Bold Text = Indicates Stainless Steel model parts. Item Rec. Qty. Parts (Order from this column only) Reed Switch & Hall Effect are unavailable without meter cap. Model: FPD1203-HP TERMINAL BLOCK Part or Set Part Description...
  • Page 9 SPECIFICATIONS Flow Ranges (LPM or GPM) Above 5 centipoise Below 5 centipoise Accuracy of Reading Maximum Viscosity Maximum Operating Pressure Maximum Operating Temperature Pulse Type Pulses per Litre/Gallons Meter Dimensions Weight Unless high viscosity rotors are fitted. Pulse Meter Models 15 to 500 / 4.0 to 132 25 to 500 / 6.0 to 132 ±...
  • Page 12 M-4125 / 0405...

This manual is also suitable for:

Fpd1202-hpFpd1203-hp