Omron NE-C29 Instruction Manual
Omron NE-C29 Instruction Manual

Omron NE-C29 Instruction Manual

Compressor nebulizer
Hide thumbs Also See for NE-C29:

Advertisement

INSTRUCTION MANUAL
TM
Compressor Nebulizer
NE-C29
Model

Advertisement

Table of Contents
loading

Summary of Contents for Omron NE-C29

  • Page 1 INSTRUCTION MANUAL Compressor Nebulizer NE-C29 Model...
  • Page 2: Table Of Contents

    Guide to Using the NE-C29 ........
  • Page 3: Before Using The Unit

    Before Using the Unit IMPORTANT SAFETY NOTES To assure the correct use of the product basic safety measures should always be followed including the precautions listed below: WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
  • Page 4 Do not use or store the device while the air tube is bent. Approved for human use only. Use only original OMRON parts and accessories. Use of unsupported parts may damage the device. Do not add more than 7 ml of medication to the medication cup.
  • Page 5 IMPORTANT SAFETY NOTES Never place, or attempt to dry the compressor, the power cord or nebulizing parts in a microwave oven. General Safety Precautions: Inspect the device and parts before using the them each time, and check that there are no problems.
  • Page 6: Know Your Unit

    KNOW YOUR UNIT Compressor (Main Unit) Nebulizing Parts Storage Compartment Cover Inhalation Attachments Power Switch Mouthpiece Adult Mask Ventilation Slots Nebulizer Kit Holder Air Plug Air Filter Cover (*Air Filter Inside) Air Connector Child Mask Air Plug Nosepiece Air Tube (Option) Rear View Nebulizer Kit...
  • Page 7 KNOW YOUR UNIT Accessories: Instruction Manual Spare Air Filters x 5...
  • Page 8: Guide To Using The Ne-C29

    GUIDE TO USING THE NE-C29 HOW TO PREPARE THE NEBULIZER FOR USE (Page 8) NOTE: Clean and disinfect the nebulizer kit and applicable inhalation attachments before using the device for the first time, or if it has not been used for a while.
  • Page 9: Operating Instructions

    Operating Instructions HOW TO PREPARE THE NEBULIZER FOR USE WARNING: Clean and disinfect the nebulizer kit, mouthpiece and optional nosepiece or masks before using them for the first time after purchase, if the device has not been used for a long period of time. For directions on cleaning and disinfecting the parts of the device refer to page 15 in this instruction manual.
  • Page 10 HOW TO PREPARE THE NEBULIZER FOR USE 5. Remove the baffle from the medication cup. 6. Add the correct amount of prescribed medication to the medication cup. CAUTION: The capacity of the medication cup is 2 to 7 ml. 7. Reattach the baffle to the medication cup. 8.
  • Page 11 HOW TO PREPARE THE NEBULIZER FOR USE 9. Attach the desired inhalation attachment, as described below. Attach the cap when using the mouthpiece or optional nosepiece. Using the cap with these attachments will reduce the amount of medication that is discharged into the air. Attaching the Mouthpiece 1) Attach the cap to the inhalation air inlet.
  • Page 12 HOW TO PREPARE THE NEBULIZER FOR USE 10 .Attach the air tube. 1) Attach the air tube to the air connector on the compressor. 2) Attach the other end of the air tube to the air tube connector on the medication cup. NOTES: •...
  • Page 13: How To Take Medication

    HOW TO TAKE MEDICATION 1. Hold the nebulizer kit as indicated on the right. CAUTION: Do not tilt the nebulizer kit so that it is at an angle of greater than 45°. Medication may flow into the mouth. 45° 2. Press the power switch to the on ( ) position. The compressor starts and nebulization starts.
  • Page 14 HOW TO TAKE MEDICATION 3. Inhale medication as according to your doctor’s and/or health care adviser’s instructions. Using the Mouthpiece Insert the mouthpiece into your mouth and inhale the medication breathing normally. Exhale as normal through the mouthpiece. Using the Adult Mask Attach the mask so that it covers your nose and mouth and inhale the medication.
  • Page 15 HOW TO TAKE MEDICATION 4. Complete your treatment. 1) When you have finished inhaling your medication, turn the compressor off. Press the power switch to the off position. 2) Unplug the air tube from the nebulizer kit. NOTE: Always hold the air plug when disconnecting the air tube. 3) Check that there is no condensation or moisture remaining in the air tube.
  • Page 16: Care And Maintenance

    Care and Maintenance CLEANING AND DAILY DISINFECTING Following the cleaning instructions after each use will prevent any remaining medication in the bottle from drying resulting in the device not nebulizing effectively and also for preventing infections. WARNING: Be sure to wash the parts after use, and dry the parts immediately after washing them.
  • Page 17: Maintenance And Storage

    MAINTENANCE AND STORAGE 1. Assemble the nebulizing parts. 2. If the compressor is dirty, wipe it clean with a soft cloth moistened with water or mild detergent. WARNING: The compressor is not waterproof. 3. If the outside of the air tube is dirty, wipe it clean with a soft cloth moistened with water or mild detergent.
  • Page 18 MAINTENANCE AND STORAGE To keep your device in the best condition and protect the device from damage follow these directions: CAUTION: • Do not drop the compressor or nebulizer kit, or subject them to strong shocks. • Do not carry or leave the nebulizer while the medication cup contains medication.
  • Page 19: How To Change The Air Filter

    Do not boil the air filter cover. Remove the air filter cover, wash it, and make sure it is dry and reattached correctly. • Please contact your OMRON dealer for additional air filters, or if the parts supplied with the device are damaged or missing.
  • Page 20: Troubleshooting Tips

    • If the suggested remedy does not solve the problem, do not try to repair the device - no parts of the unit are user serviceable. Return the unit to an authorized OMRON dealer. • The device should be serviced once a year by an approved OMRON service centre.
  • Page 21: Specifications

    SPECIFICATIONS NE-C29 Model: Non-heating compressor nebulizer Type: 230V, 50Hz model ; 230V, 60Hz model Electrical: 138VA Power Consumption: 0.4 ml/min (without cap) Nebulizer Rate: *MMD approximately 5 µm (based on EN13544-1) Particle Size: 7 ml (cc) max. Medication Cup Capacity:...
  • Page 22: Optional Parts And Accessories

    OPTIONAL PARTS AND ACCESSORIES Nebulizer Kit Set Nosepiece Model No. C28NEBKIT Model No. C28NP Nebulizer Kit Mouthpiece Air Tube Mouthpiece Filter Cover Model No. C30TUBE Model No. C28MP Model No. C28FLCVR Air Filters (x 5) Adult Mask Child Mask Model No. C28AM Model No.
  • Page 23: Notes

    NOTES...