AMX AXlink Bus Controllers AXB-232++ Instruction Manual

AMX AXlink Bus Controllers AXB-232++ Instruction Manual

Amx corporation instruction manual
Hide thumbs Also See for AXlink Bus Controllers AXB-232++:

Advertisement

Quick Links

instruction manual
AXB-232++
RS-232/422/485 Interface
A X l i n k B u s C o n t r o l l e r s

Advertisement

Table of Contents
loading

Summary of Contents for AMX AXlink Bus Controllers AXB-232++

  • Page 1 instruction manual AXB-232++ RS-232/422/485 Interface A X l i n k B u s C o n t r o l l e r s...
  • Page 3: Table Of Contents

    Table of Contents Product Information ...1 Front Panel... 1 Rear Panel ... 1 Specifications ... 2 Installation and Wiring ...3 Setting the Internal Jumpers ... 3 Setting jumper JP4 to terminate RS-422 input with 100 ohms... 3 Setting jumper JP5 to set the RS-422 port for RS-485 use ... 4 Setting the DIP Switches...
  • Page 4 Table of Contents AXB-232++ RS-232/422/485 Interface...
  • Page 5: Product Information

    Product Information The AXB-232++ RS-232/422/485 Interface is an AXlink bus controller that provides remote control for devices that require a variety of control protocols. The AXB-232++ extends RS-232, RS-422, or RS-485 control to remote sources over the 4-wire AXlink data/power bus. Onboard processing and memory allows the controller to take on complex tasks by itself, reducing the processing burden for the Axcess control system.
  • Page 6: Specifications

    Product Information Specifications The following table lists the specifications for the AXB-232++. Specifications Power Processor Asynchronous data standards Buffers Front Panel AXlink LEDs RX LED (Red) TX LED (Red) DEVICE DIP Switch RS232/422 DIP Switch Rear Panel Hardware handshaking connector RS422/232 connector AXlink connector Internal Jumpers...
  • Page 7: Installation And Wiring

    Installation and Wiring Installation and Wiring The AXB-232++ can be used as an independent RS-232/422/485-controlled interface by setting the internal jumpers. Configure the communication parameters using the DIP switches on the front panel. Setting the Internal Jumpers Internal jumper JP4 Internal jumper JP5 front 1998...
  • Page 8: Setting Jumper Jp5 To Set The Rs-422 Port For Rs-485 Use

    7. Replace the panel, and refasten the screws. 8. Reconnect the RS-232/422/485 connectors. Setting the DIP Switches Use the DIPSwitch 2.0 application available for free download from AMX to quickly figure out DIP Switch settings for all types of DIP Switches. Setting the DEVICE DIP switch Set the device number on can be 1 of the 255 devices in an Axcess control system.
  • Page 9: Setting The Rs-232/422 Dip Switch

    Setting the RS-232/422 DIP switch Set the stop bits, data bits, parity, and baud rate on the RS-232/422 DIP switch, located on the front panel (see FIG. 1 on page 1). The AXB-232++ supports the following asynchronous data standards: Stop bits 1 and 2 Data bits 7, 8, and 9 Parity None, Odd, Even, Mark, and Space Baud rates 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200 and 38,400.
  • Page 10: Wiring Devices To The Axb-232

    Installation and Wiring Wiring Devices to the AXB-232++ Preparing captive wires To connect the wiring into a captive-wire connector: 1. Strip 1/4 inch off the wire insulation for all four wires. 2. Tin 2/3 of the exposed wire. 3. Insert each wire into the appropriate captive-wire connector up to the insulation. 4.
  • Page 11: Using Rs-232

    Using RS-232 When communicating via RS-232, connect the wiring as shown in FIG. 6. AXB- 232++ +12V RX - RX + TX - TX + FIG. 6 RS-232 wiring Using Hardware Handshaking When the controlled device requires hardware handshaking, connect the wiring as shown in FIG. 7. AXB-232++ FIG.
  • Page 12: Rack-Mounting The Axb-232++ (Optional)

    Installation and Wiring Rack-mounting the AXB-232++ (optional) To rack-mount the AXB-232++ into the optional AC-RK Accessory Rack Kit: 1. Remove any connected power, and AXlink and RS-232 connectors from the rear panel. 2. Remove the two screws on the front panel of the AXB-232++. 3.
  • Page 13: Programming

    Programming Send_Commands The AXB-232++ supports the same command set as the AXC-232. The following table lists the AXB-232++ Send_Commands. AXB-232++ Send_Commands B9MOFF Sets data bit mode to normal with DIP switch settings (default). B9MON Enables a special mode to override DIP switch settings. BAUDHIGH Enables 115,200 baud rate when the DIP switch is set to...
  • Page 14 Programming AXB-232++ Send_Commands (Cont.) CHARD Sets delay between all transmitted characters to the increment specified. CTSPSH Enables PUSHes and RELEASEs. CTSPSHF Disables the 'CTSPSH' command. EOFF Disables the 'EON ' command (default). Forces the AXB-232++ to ignore the transmitted char- acters on its receiver.
  • Page 15: Axcess Program Characteristics

    AXB-232++ Send_Commands (Cont.) RXOFF AXB-232++ does not pass on received characters to the Master (default). RXON Enables AXB-232++ to send incoming characters received to the Master. TXCLR Clears and stops any charac- ters waiting in the Transmit buffer. XOFF Disables software handshaking (default).
  • Page 16: Send_String Escape Sequences

    Programming Send_String Escape Sequences The AXB-232++ does not regard certain three-character combinations within a Send_String program as literal characters, but as commands. The following table lists those combinations. Send_String Escape Sequences 27,17,<time> Sends a break character of the specified length of time. 27,18,1 Sets the ninth data bit to 1 for all of the following characters...
  • Page 17: Axb-232++ Program Statements

    AXB-232++ Program Statements The Axcess program of the AXB-232++ communicates with the master as Device 0. Its device communicates with the RS232/422 Input/Output (I/O) of the AXB-232++ as Device 1. The following table lists AXB-232++ statements. AXB-232++ Program Statements Statement CREATE_BUFFER 0,buffer CREATE_BUFFER...
  • Page 18: Xmodem Timing Commands

    Programming Xmodem Timing Commands The following table lists the AXB-232++ Xmodem timing commands. Xmodem timeouts exist to accommodate potential Ethernet delays and for consistency among and within products. Any Xmodem timing command will change timing and retries for Axcess code download as well as Softrom transfer.
  • Page 19: Reserved Channels

    Reserved Channels The following table lists the channels reserved on Device 0. Reserved Channels Channel Channel 254 Channel 255 Axcess Master Mode When an Axcess device is placed in "Master Mode", the Central Controller’s moved to the Axcess device’s RS-232 port. Press the escape key, then type either MC or MD: <esc>MC - connects the device in Master Mode <esc>MD - disconnects the device...
  • Page 20 ATLANTA • BOSTON • CHICAGO • CLEVELAND • DALLAS • DENVER • INDIANAPOLIS • LOS ANGELES • MINNEAPOLIS • PHILADELPHIA • PHOENIX • PORTLAND • SPOKANE • TAMPA 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA • 800.222.0193 • 469.624.8000 • 469-624-7153 fax • 800.932.6993 technical support • www.amx.com...