Napoleon GVFS20P Installation And Operating Instructions Manual

Propane/natural gas unvented millivolt system

Advertisement

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: ANSI Z21.11.2B, VOLUME II FOR UNVENTED ROOM HEATERS.
GVFS20P
PROPANE
GVFS20N
NATURAL GAS
UNVENTED MILLIVOLT
SYSTEM
CERTIFIED FOR THE UNITED STATES USING ANSI METHODS.

SAFETY INFORMATION

WARNING
!
If the information in these instructions are
not followed exactly, a fi re or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
- This is an unvented gas-fi red heater that
uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and
ventilation air must be provided.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
10.00$
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
1.23
W415-0559 / C / 10.04.10
1

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon GVFS20P

  • Page 1: Safety Information

    INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE. INSTALLATION AND OPERATING INSTRUCTIONS CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: ANSI Z21.11.2B, VOLUME II FOR UNVENTED ROOM HEATERS. GVFS20P PROPANE GVFS20N NATURAL GAS UNVENTED MILLIVOLT SYSTEM CERTIFIED FOR THE UNITED STATES USING ANSI METHODS.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION INSTALLATION COMBUSTION AND VENTILATION AIR PROVISIONS DETERMINING CONFINED OR UNCONFINED SPACE GAS INSTALLATION OPTIONAL WALL SWITCH / THERMOSTAT MOBILE HOME INSTALLATION FINISHING CAST FRONT INSTALLATION AND REMOVAL SCREEN INSTALLATION AND REMOVAL LOGO PLACEMENT LOG PLACEMENT...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW Cast top, see “FINISHING - CAST FRONT INSTALLATION AND REMOVAL” section. Blower, see “OPTIONAL BLOWER INSTALLATION” section. Door, see “FINISHING - SCREEN INSTALLATION AND REMOVAL” section. Rating Plate, see “RATING PLATE INFORMATION” section. W415-0559 / C / 10.04.10...
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Under no circumstances should this appliance be modifi ed. •...
  • Page 5: Dimensions

    DIMENSIONS " " " " GENERAL INSTRUCTIONS WARNING * CARBON MONOXIDE POISONING MAY LEAD TO DEATH EARLY SIGNS OF CARBON MONOXIDE POISONING RESEMBLE THE FLU, WITH HEADACHE, DIZZINESS AND/OR NAUSEA. IF YOU HAVE THESE SIGNS, THE HEATER MAY NOT BE WORKING PROPERLY.
  • Page 6: General Information

    In absence of local codes, install the appliance to the current National Fuel Gas Code, ANSI Z223.1 Installation Code which can be obtained from: American National Standards Institute Inc. National Fire Protection Association Inc. 1430 Broadway Batterymarch Park New York, NY 10018 Quincy, MA 02269 The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
  • Page 7: Rating Plate Information

    RATING PLATE INFORMATION CONFORMS TO: ANSI Z21.11.2a-2008, UNVENTED GAS FIRED ROOM HEATER THIS IS A GAS-FIRED UNVENTED THIS UNIT IS NOT APPROVED FOR DIAGRAM TO AID THE OPERATION AGRAM TO AGRAM TO ROOM HEATER THAT REQUIRES BEDROOM, BATHROOM AND ADEQUATE COMBUSTION BED-SITTING ROOM OF THIS FIREPLACE OF THIS...
  • Page 8: Installation

    3.0 INSTALLATION THIS GAS HEATER SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifi cs that apply to your area. Provide adequate ventilation and combustion air.
  • Page 9: Determining Confined Or Unconfined Space

    DETERMINING CONFINED OR UNCONFINED SPACE To determine the volume of the room where the appliance is to be installed, multiply the width x the length x the ceiling height of that room measured in feet. If any adjoining rooms are connected by grilles or openings such as kitchen pass-throughs, etc., the volume of those rooms may be added to the total.
  • Page 10: Gas Installation

    EXAMPLE 1: In this example, because there is no door to the adjoining room, the volume of the adjoining room may be added to the volume of the room with the heater to get a total unconfi ned space. The total unconfi ned space: 800 + 1200 = 2000 cubic feet. Maximum BTU/h: 2000x1000 = 40,000 BTU/h 19.2 If there are no more fuel burning appliances within this space then the 23,000 BTU/h input of the heater is...
  • Page 11: Optional Wall Switch / Thermostat

    OPTIONAL WALL SWITCH / THERMOSTAT WARNING DO NOT CONNECT EITHER THE WALL SWITCH, THERMOSTAT OR GAS VALVE DIRECTLY TO 110 VOLT ELECTRICITY. For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location.
  • Page 12: Finishing

    4.0 FINISHING CAST FRONT INSTALLATION AND REMOVAL WARNING SCREENS MUST BE CLOSED WHILE THE APPLIANCE IS IN OPERATION. Lift the top cast piece off of the heater. SCREWS BRACKET Detach the front cast piece from the side pieces by removing FRONT the screws from the brackets located in the upper inside corners.
  • Page 13: Log Placement

    LOG PLACEMENT WARNING LOGS MUST BE PLACED IN THEIR EXACT LOCATION IN THE APPLIANCE. DO NOT MODIFY THE PROPER LOG POSITIONS, SINCE APPLIANCE MAY NOT FUNCTION PROPERLY. DELAYED IGNITION AND CARBON / SOOT DISTRIBUTION THROUGHOUT THE LIVING AREA MAY OCCUR. THE LOGS ARE FRAGILE AND SHOULD BE HANDLED WITH CARE.
  • Page 14: Optional Blower Installation

    5.0 OPTIONAL BLOWER INSTALLATION BLOWER INSTALLATION AND CONNECTION SEE LOCATION AND CLEARANCES IN INSTRUCTION MANUAL Cut and remove the tie securing the blower switch wires to the heat shield. Connect the white wire coming from below the heater to the terminal on the blower.
  • Page 15: Operation

    6.0 OPERATION WARNING When lit for the first time, the appliance will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the “burn-in” of internal paints and lubricants used in the manufacturing process and will not occur again. After extended periods of non-operation such as following a vacation or a warm weather season, the appliance may emit a slight odour for a few hours.
  • Page 16: Adjustment

    7.0 ADJUSTMENT VENTURI ADJUSTMENT WARNING CARBON CAN BE DISTRIBUTED IN SURROUNDING LIVING AREA IF THE AIR SHUTTER IS IMPROPERLY ADJUSTED. 49.5 This appliance has an air shutter that has been factory set open according to the chart below: VENTURI BURNER Regardless of venturi orientation, closing the air shutter will cause a more yellow flame, but can lead to carboning.
  • Page 17: Maintenance

    8.0 MAINTENANCE MAINTENANCE MAINTENANCE WARNING MAINTENANCE TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
  • Page 18: Pilot Indicator Light Battery Replacement

    PILOT INDICATOR LIGHT BATTERY REPLACEMENT If the pilot indicator light no longer fl ashes and the pilot is burning, the batteries may require replacing. Four "AA" batteries are required and should be replaced annually. Open the switch housing by removing the top screw, then pivoting the box open.
  • Page 19: Replacements

    9.0 REPLACEMENTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Authorized dealer / distributor. FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.
  • Page 20 ACCESSORIES PART NO. DESCRIPTION REMOTE CONTROL THERMOSTATIC REMOTE CONTROL F50DR THERMOSTATIC REMOTE CONTROL F50DY THERMOSTATIC REMOTE CONTROL F50DK THERMOSTATIC REMOTE CONTROL GS-65KT BLOWER KIT GDSLL-KT LEG LEVELLING KIT GS-331S STOVE TOP INSET - SOAPSTONE GS-331F STOVE TOP INSET - GRANITE - GREEN GS-331N STOVE TOP INSET - GRANITE - BROWN W660-0026...
  • Page 21: Trouble Shooting

    10.0 TROUBLE SHOOTING WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 22 SYMPTOM PROBLEM TEST SOLUTION Pilot burning; Thermostat or switch is Connect a jumper wire across the wall switch no gas to main defective. terminals; if main burner lights, replace switch / burner; gas thermostat. knob is on ‘HI’; Wall switch wiring is Disconnect wires from valve.
  • Page 23 SYMPTOM PROBLEM TEST SOLUTION Flames are Unit is over-fi red or under- Check pressure readings: consistently too fi red. Inlet pressure can be checked by turning screw (A) large or too small. counter-clockwise 2 or 3 turns and then placing Carboning occurs.
  • Page 24: Warranty

    11.0 WARRANTY NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2008 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station. The complete appliance is again thoroughly inspected by a qualifi...
  • Page 25: Service History

    12.0 SERVICE HISTORY 43.1 W415-0559 / C / 10.04.10...
  • Page 26 13.0 NOTES 44.1 W415-0559 / C / 10.04.10...
  • Page 27 44.1 W415-0559 / C / 10.04.10...
  • Page 28 44.1 W415-0559 / C / 10.04.10...