Bryant LEGACY 912SA Product Data

Bryant LEGACY 912SA Product Data

92.1 afue legacy line single-stage 4-way multipoise condensing gas furnace
Hide thumbs Also See for LEGACY 912SA:

Advertisement

912SA 92.1 AFUE
LEGACYt LINE SINGLE- -STAGE
4- -WAY MULTIPOISE
CONDENSING GAS FURNACE
The 912S Multipoise Condensing Gas Furnace is part of the
Legacyt Line product offering. Sporting a PSC blower motor
and an Annual Fuel Utilization Efficiency (AFUE) of 92.1%, this
single-stage
gas
furnace
homeowners. This Legacy Line Gas Furnace also features 4-way
multipoise installation flexibility, and is available in eight model
sizes. The 912S can be vented for direct vent/two-pipe, ventilated
combustion air, or single-pipe applications. A BryantR Air
Conditioner or Heat Pump can be used to form a complete system.
All units meet California Air Quality Management District
emission requirements. These furnaces are approved for
Manufactured Housing (Mobile Home) applications. All sizes are
design certified in Canada.
Product Data
provides
efficient
comfort
STANDARD FEATURES
S 4-way multipoise design for upflow, downflow or horizontal
installation.
S Optional through-the-cabinet downflow venting.
S Installation flexibility with a 360-degree rotating elbow.
S Ideal condensing furnace height 35" cabinet: short enough for
taller coils, but still allows enough room for service.
S Silicon Nitride Perfect Lightt Hot Surface Igniter.
S Aluminized-steel primary heat exchanger.
S Stainless-steel condensing secondary heat exchanger.
S High-quality corrosion-resistant prepainted steel cabinet with
hemmed edges for safety.
S Factory-configured ready for upflow applications.
S Direct-vent/sealed combustion, single-pipe venting or ventilated
combustion air.
S PSC blower motor, single-speed inducer motor, and single-stage
gas valve.
A11264
S Self-diagnostics
S Approved for Twinning applications (42060 through 60120
sizes, only).
S Propane convertible (See accessory list).
S Approved for Manufactured Housing/Mobile Home applications
with MH accessory kit.
for
S Convenient Air Purifier and Humidifier connections.
S Residential installations may be eligible for consumer financing
through the Retail Credit Program.
S Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1-inch water column with all
present air inlets, air outlets, and condensate drain port(s) are
sealed.
Use of the AHRI Certified
Mark indicates a
TM
manufacturer's participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
1
CERTIFIED

Advertisement

Table of Contents
loading

Summary of Contents for Bryant LEGACY 912SA

  • Page 1 912SA 92.1 AFUE LEGACYt LINE SINGLE- -STAGE 4- -WAY MULTIPOISE CONDENSING GAS FURNACE Product Data STANDARD FEATURES S 4-way multipoise design for upflow, downflow or horizontal installation. S Optional through-the-cabinet downflow venting. S Installation flexibility with a 360-degree rotating elbow.
  • Page 2: Features And Benefits

    Monoport Burners — The burners are specially designed and Power Heatt Igniter — Bryant’s unique SiN igniter is not only finely tuned for smooth, quiet combustion and economical physically robust but it is also electrically robust. It is capable of operation.
  • Page 3: Specifications

    SPECIFICATIONS Heating Capacity and Efficiency 30040 30060 42060 48080 60080 42100 60100 60120 Input High Heat (BTUH) 40,000 60,000 60,000 80,000 80,000 100,000 100,000 120,000 Output High Heat (BTUH) 39,000 58,000 58,000 78,000 78,000 97,000 97,000 117,000 Efficiency AFUE % (ICS) 92.1 92.1 92.1...
  • Page 4: Furnace Components

    MODEL NUMBER NOMENCLATURE Example of a Model Number 1 - 2 8 - 10 6 - 7 12 - 13 Family/Tier Base Eff. Major Series Htg. Stages Htg. Cap. Motor Width Clg. Cap. Voltage Minor Series Features 91 - Legacy 0 - +90 AFUE 2 - +92 AFUE 92 - Preferred...
  • Page 5 ACCESSORIES DESCRIPTION PART NUMBER 30040 30060 42060 48080 60080 42100 60100 60120 Venting Accessories Vent Kit - Through the Cabinet KGADC0101BVC Vent Terminal - Concentric - 2” (51 mm) KGAVT0701CVT Vent Terminal - Concentric - 3” (76 mm) KGAVT0801CVT See Venting Tables Vent Terminal Bracket - 2”...
  • Page 6 AIR DELIVERY - - CFM (BOTTOM RETURN WITH FILTER) EXTERNAL STATIC PRESSURE (IN.W.C.) UNIT RETURN-AIR SPEED SIZE CONNECTION TAPS Black 1100 1055 1010 Yellow 030040 SIDE/BOTTOM Blue Black 1340 1295 1245 1190 1130 1065 1005 Yellow 1035 1010 030060 SIDE/BOTTOM Blue Black 1665...
  • Page 7 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) Table 1 – Maximum Equivalent Vent Length - - Ft. (M) 0 to 4500 Ft. (0 to 1370 M) Altitude NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
  • Page 8: Venting System Length Calculations

    Venting System Length Calculations The Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalent length of elbows used in the venting system from Table 2. Standard vent terminations or factory accessory concentric vent terminations count for zero deduction. See vent system manufacturer’s data for equivalent lengths of flexible vent pipe or other termination systems.
  • Page 9 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) (CONTINUED) Table 3 – Maximum Equivalent Vent Length - - Ft. (M) 4501 to 10,000 Ft. (0 to 1370 M) Altitude NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
  • Page 10 MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE - - FT. (M) Maximum Length of Uninsulated and Insulated Vent Pipe-Ft (M) No Insulation 3/8-in. (9.5 mm) Insulation 1/2-in. (12.7 mm) Insulation Single Stage Pipe Pipe Diameter-inches (mm) Pipe Diameter-inches (mm) Pipe Diameter-inches (mm) Winter Design Furnace Length in...
  • Page 11: Return Air Temperature

    RETURN AIR TEMPERATURE This furnace is designed for continuous return- -air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C) db such as when used with a night setback thermometer. Return- -air temperature must not exceed 80_F (27_C) db. Failure to follow these return air limits may affect reliability of heat exchangers, motors and controls.
  • Page 12 DOWNFLOW SUBBASE LOCATING / 4-IN. TYP PLENUM OPENING LOCATING FACTORY-SUPPLIED FIELD-INSTALLED INSULATION A97427 A88207 Assembled Disassembled DIMENSIONS (IN. / MM) PLENUM OPENING* FLOOR OPENING HOLE NO. FOR FURNACE FURNACE IN DOWNFLOW WIDTH CASING WIDTH APPLICATION ADJUSTMENT Furnace with or without Cased Coil 11--- 3/16 13--- 7/16 20--- 5/8...
  • Page 13: Typical Wiring Schematic

    MEDIA FILTER CABINET 25-5/8" (651mm) 24-1/4” 23-5/8" (616mm) (600mm) Opening with Flanges Bent 23-1/8” 23-3/8” (588mm) (594mm) Opening Duct Side Furnace Side 23-3/4” (603mm) " Centerline Screw Slots Media Filter (146mm) Cabinet 17" (432mm) 16" (406mm) 16" (406mm) 20" (508mm) 21"...
  • Page 14: Dimensional Drawing

    DIMENSIONAL DRAWING A12267 912SA SHIP WT. LB (KG) FURNACE SIZE CABINET WIDTH OUTLET WIDTH BOTTOM INLET WIDTH AIR INTAKE 30040 123.0 (55.4) 14--- 3/16 (361) 12--- 1/2 (319) 12--- 9/16 (322) 7--- 1/8 (181) 30060 127.0 (57.2) 42060 144.0 (64.8)
  • Page 15: Guide Specifications

    GUIDE SPECIFICATIONS General System Description Primary Heat Exchangers Furnish a ______________________ 4- -way multipoise gas- -fired Primary heat exchangers shall be 3- -Pass corrosion- -resistant condensing furnace for use with natural gas or propane (factory- - aluminized steel of fold- -and- -crimp sectional design and applied authorized conversion kit required for propane).
  • Page 16 Catalog No. PDS912SA ---02 E2012 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Edition Date: 09/12 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.