Troubleshooting - York Fitness Aspire Owner's Manual

Cross trainer
Hide thumbs Also See for Aspire:
Table of Contents

Advertisement

troubleshooting

!
IF YOU HAVE A PROBLEM WITH YOUR EXERCISE CYCLE, BEFORE YOU DO ANYTHING ELSE PLEASE CHECK THAT ALL
THE CABLES HAVE BEEN CONNECTED CORRECTLY. LOOSE CABLES ARE VERY COMMON AND MANY PROBLEMS CAN
The following table details the most common problems and how to fix them. If you still have a problem after going through the
troubleshooting guide please call your local YORK distributor for advice.
PROBLEM
NO DISPLAY
NO SPEED DISPLAY
PARTIAL DISPLAY
NO PULSE SIGNAL
ERROR CODE: E1
ERROR CODE: E2
ERROR CODE: E3
ERROR CODE: ERR
ERROR CODE: E5
FOR YOUR OWN SAFETY, DO NOT OPEN PROTECTIVE CASING. IF ERROR PERSIST, PLEASE CONTACT YOUR LOCAL YORK
DISTRIBUTOR FOR ADVICE. KEEP THE EQUIPMENT OUT OF USE UNTIL IT IS REPAIRED.
If you are having problems with your heart rate reading, please note that some fibres used in clothes eg) polyester, create static electricity
that may prevent a reliable heart rate reading. Mobile phones, TV's, microwaves and other electrical appliances that generate an
electromagnetic field may also interfere with heart rate measurement.
20
BE SOLVED BY MAKING SURE THE CABLES ARE PROPERLY CONNECTED.
CAUSE
No power
System halted
Wires are damaged or not connected properly
Speed sensor is too far from magnet
The PA board is not connected properly
Wires are damaged or not connected properly
Too much hand movement
Palms too wet
Hand Pulse Sensor is being gripped too tightly
User is wearing rings
Computer console error
Motor is non-operational or damaged
Wires are damaged or not connected properly
User is over maximum weight tolerance
Computer console error
Motor controller is non-operational or damaged
No pulse signals received for 8 seconds during body fat
program
Auto-tension controller error or is non-operational
CORRECTION
Make sure power cord is plugged in properly
Unplug and re-plug the power cord to reset the system
Verify all wires are connected properly
If problem persist, contact your local YORK distributor
Unplug and re- plug the power cord to reset the system
Verify all wires are connected properly
Disconnect and re-connect all cables
If problem persist, contact your local YORK distributor
Verify all wires are connected properly
Dry palms
Grip using moderate pressure
Remove all rings
If problem persist, contact your local YORK distributor
Verify all wires are connected properly
Unplug and re-plug the power cord to reset the system
Check maximum user weight
If problem persist, contact your local YORK distributor
Verify all wires are connected properly
If problem persist, contact your local YORK distributor
Verify all wires are connected properly
If problem persist, contact your local YORK distributor
Refer to "NO PULSE SIGNAL"
Verify all wires are connected properly
If problem persist, contact your local YORK distributor

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents