INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33 ● ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.

SAFETY INFORMATION

WARNING
!
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
If the information in these instructions
are not followed exactly, a fi re or
explosion may result causing property
damage, personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certifi ed kit is used.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
$10.00
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
NATURAL GAS MODEL
PROPANE GAS MODEL
WARNING
!
GD36NTR
BGD36NTR
GD36PTR
BGD36PTR
B G
D I
L L U
S T
R A
T E
D
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
1.28C
W415-0773 / E / 03.13.12
1

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon GD36PTR

  • Page 1: Safety Information

    CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS. NATURAL GAS MODEL SAFETY INFORMATION WARNING GD36PTR CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS. If the information in these instructions BGD36PTR are not followed exactly, a fi re or...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION GD36 DIMENSIONS BGD36 DIMENSIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION VENTING VENTING LENGTHS AND COMPONENTS TYPICAL VENT INSTALLATION SPECIAL VENT INSTALLATIONS 3.3.1 PERISCOPE TERMINATION (GD36 AND BGD36) 3.3.2 CORNER TERMINATION MINIMUM AIR TERMINAL LOCATION CLEARANCES VENTING APPLICATION FLOW CHART DEFINITIONS ELBOW VENT LENGTH VALUES...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW See the section “MINIMUM ENCLOSURE CLEARANCES” for drywall (or other combus- tible material). See the section “MINIMUM MANTEL CLEARANCES”. See the section “VENTING” and “INSTALLATION”. See the section “FRAMING”. See the section “FRAMING”. Side Wall See the section “RATING PLATE INFORMATION”.
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES TO THIS APPLIANCE OR IT’S CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi...
  • Page 5: Gd36 Dimensions

    GD36 DIMENSIONS " " 27" " 4" DIA. 33" 7" DIA. " " " INLET " 3" " " " ELECTRICAL INLET LEFT SIDE BGD36 DIMENSIONS " " " 27" 4" DIA. " 7" DIA. " " " INLET " 3"...
  • Page 6: General Instructions

    GENERAL INSTRUCTIONS WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPENED OR REMOVED. PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE. PROVIDE ADEQUATE VENTILATION. NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48”...
  • Page 7: General Information

    GENERAL INFORMATION FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY! GD36 RATES AND EFFICIENCIES BGD36 RATES AND EFFICIENCIES Altitude (FT) 0-4,500 0-4500 Altitude (FT) 0-4,500 0-4,500 Max. Input (BTU/ 26,000 26,000 Max. Input 18,000 17,000 (BTU/HR) Max.
  • Page 8: Rating Plate Information

    RATING PLATE INFORMATION CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: CSA 2.22b-2009, ANSI Z21.50b-2009 VENTED GAS FIREPLACE / FOYER AU GAZ AVEC EVACUATION. DIRECT VENT GAS FIREPLACE. SUITABLE FOR BEDROOM, BATHROOM AND FOYER A GAZ VENTILE DIRECT. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A OGUE BED-SITTING ROOM INSTALLATION.
  • Page 9: Venting

    3.0 VENTING Models GD36 and BGD36 may be vented either as a top vent or a rear vent. Refer to the section applicable to your installation. WARNING RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE. IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3 FEET FOR BOTH VERTICAL AND HORIZONTAL RUNS.
  • Page 10: Venting Lengths And Components

    VENTING LENGTHS AND COMPONENTS Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent and Metal-Fab follow the installation procedure provided with the venting components.
  • Page 11: Typical Vent Installation

    TYPICAL VENT INSTALLATION 16" MINIMUM 16" MINIMUM 40 FT 40 FT MAXIMUM MAXIMUM 3 FT 3 FT MINIMUM MINIMUM 33" 24 1/4" MIN REAR VENT TOP VENT W415-0773 / E / 03.13.12...
  • Page 12 24" MAXIMUM GD36 24" 20" MAXIMUM MINIMUM 57" MINIMUM PLUS RISE* 33" 24 1/4" MINIMUM PLUS RISE* 24" MAXIMUM BGD36 10" 20" MAXIMUM MINIMUM 42 3/8" MINIMUM PLUS RISE* 32 3/8" 24 1/4" MINIMUM PLUS RISE* * See "VENTING" section W415-0773 / E / 03.13.12...
  • Page 13: Special Vent Installations

    SPECIAL VENT INSTALLATIONS 3.3.1 PERISCOPE TERMINATION (GD36 AND BGD36) Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum 12” above grade. The maximum allowable vent length is 10’...
  • Page 14: Minimum Air Terminal Location Clearances

    MINIMUM AIR TERMINAL LOCATION CLEARANCES COVERED BALCONY APPLICATIONS ††* = 3 feet = 2 x ACTUAL INSTALLATIONS feet CANADA U.S.A. 12” 12” Clearance above grade, veranda porch, deck or balcony. 12” Δ 9” Δ Clearance to windows or doors that open. 12”...
  • Page 15: Venting Application Flow Chart

    VENTING APPLICATION FLOW CHART TOP EXIT Horizontal Termination Vertical Termination Vertical rise is equal Vertical rise is equal Vertical rise is less Vertical rise is less to or greater than to or greater than than horizontal run than horizontal run the horizontal run the horizontal run Horizontal run +...
  • Page 16: Definitions

    DEFINITIONS For the following symbols used in the venting calculations and examples are: > - greater than > - equal to or greater than < - less than < - equal to or less than - total of both horizontal vent lengths (Hr) and offsets (Ho) in feet - combined horizontal vent lengths in feet - offset factor: .03 (total degrees of offset - 90°*) in feet - combined vertical vent lengths in feet...
  • Page 17: Top Exit Horizontal Termination

    TOP EXIT HORIZONTAL TERMINATION ) < (V Simple venting configuration See graph to determine the required vertical rise V for the required horizontal run H (only one 90° elbow) GD36 REQUIRED VERTICAL RISE IN FEET V 12.5 17.5 HORIZONTAL VENT RUN PLUS OFFSET IN FEET H BGD36 REQUIRED...
  • Page 18 ) > (V Simple venting configuration See graph to determine the required vertical rise V for the required horizontal run H (only one 90° elbow) BGD36 GD36 147” 147” REQUIRED REQUIRED VERTICAL VERTICAL RISE IN RISE IN INCHES V INCHES V 57”...
  • Page 19: Rear Exit Horizontal Termination

    REAR EXIT HORIZONTAL TERMINATION ) < (V Simple venting configuration See graph to determine the required vertical rise V for the required (only two 90° elbows) horizontal run H 38.3 REQUIRED VERTICAL RISE IN FEET V 12.5 17.5 HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H and H For vent configurations requiring more than two 90°...
  • Page 20 ) > (V Simple venting configuration See graph to determine the required vertical rise V for the (only two 90° elbows) required horizontal run H REQUIRED VERTICAL RISE IN INCHES V 12.5 17.5 19.25 HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H and H...
  • Page 21: Top Or Rear Exit Vertical Termination

    3.10 TOP OR REAR EXIT VERTICAL TERMINATION ) < (V See graph to determine the required vertical rise V for the Simple venting configurations. required horizontal run H REQUIRED VERTICAL RISE IN FEET V HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H and H...
  • Page 22 ) > (V See graph to determine the required vertical rise V for the Simple venting configurations. required horizontal run H REQUIRED VERTICAL RISE IN FEET V HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H and H For vent configurations requiring more than two 90°...
  • Page 23: Pre-Installation Preparation

    Example: = 1.5 FT = 5 FT = 1.5 + 1 + 5 = 6.5 FT = 1 FT = 1 FT = 10.75 FT = 1 + 1 + 10.75 = 12.75 FT = .03 (four 90° elbows + one 45° elbow - 90°) 90°...
  • Page 24: Bgd36 Rear Exit

    BGD36 REAR EXIT From inside the fi rebox, insert the 4" fl ue pipe / gasket assembly (provided) through the rear of the fi rebox. Secure the gasket assembly to the rear and top of the appliance using 4 #8 x ¾ inch Hex Head Wildrill screws supplied. Do not overtighten.
  • Page 25: Gd36 Horizontal Installation

    5.1.1 GD36 HORIZONTAL INSTALLATION WARNING THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP. TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE RETURN FLANGE OF THE MOUNTING PLATE. A.
  • Page 26: Bgd36 Horizontal Installation

    5.1.2 BGD36 HORIZONTAL INSTALLATION WARNING THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP. TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE RETURN FLANGE OF THE MOUNTING PLATE. This application occurs when venting through an exterior wall.
  • Page 27: Using Flexible Vent Components

    USING FLEXIBLE VENT COMPONENTS WARNING DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON HORIZONTAL OR VERTICAL RUNS AND ELBOWS. KEEP IT PULLED TIGHT. SPACERS ARE ATTACHED TO THE INNER FLEX PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER FLEX PIPE.
  • Page 28: Vertical Air Terminal Installation

    5.2.2 VERTICAL AIR TERMINAL INSTALLATION WARNING MAINTAIN A MINIMUM 2” SPACE BETWEEN THE AIR INLET BASE AND THE STORM COLLAR. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
  • Page 29: Using Rigid Vent Components

    USING RIGID VENT COMPONENTS The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf Steel Ltd. support ring assembly or equivalent noncombustible strapping to maintain the minimum clearance to combustibles for both vertical and horizontal runs. All inner exhaust and outer intake vent pipe joints may be sealed using either red high temperature silicone sealant W573-0002 (not supplied) or black high temperature sealant W573-0007 Mill Pac (not supplied) with the exception of the appliance exhaust fl...
  • Page 30: Vertical Air Terminal Installation

    5.3.3 VERTICAL AIR TERMINAL INSTALLATION NOTE: Before attaching elbows to the collars on the back of the appliance, 1 1/2” will need to be trimmed off the 4” collar. REAR VENT APPLICATION: Attach 4” and 7” elbows to the appliance. Secure with 3 screws and seal the joints and screw heads using high temperature sealant.
  • Page 31: Vertical Through Existing Chimney

    VERTICAL THROUGH EXISTING CHIMNEY WARNING RISK OF FIRE! CO-AXIAL TO CO-LINEAR VENTING CONFIGURATIONS MUST ONLY BE USED IN A NON- COMBUSTIBLE CHIMNEY OR ENCLOSURE. INSTALLATION IN A COMBUSTIBLE ENCLOSURE COULD RESULT IN A FIRE. This appliance is designed to be attached to a 3” co-linear aluminum fl ex vent system running the full length of a masonry chimney.
  • Page 32: Mobile Home Installation

    MOBILE HOME INSTALLATION This appliance is certifi ed to be installed as an OEM (Original Equipment Manufacturer) installation in a manufactured home or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada.
  • Page 33: Gas Installation

    GAS INSTALLATION WARNING RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES. SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 34: Optional Wall Switch

    OPTIONAL WALL SWITCH WARNING DO NOT CONNECT EITHER THE WALL SWITCH, THERMOSTAT OR GAS VALVE DIRECTLY TO 110 VOLT ELECTRICITY. For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route a 2 strand, solid core millivolt wire from the valve to the wall switch or millivolt thermostat. The recommended maximum lead length depends on wire size: WIRE SIZE MAX.
  • Page 35 It is best to frame your appliance after it is positioned and the vent system is installed. Frame to local building codes. It is not necessary to install a hearth extension with this appliance system. When roughing in the appliance, raise the appliance to accommodate for the thickness of the fi nished fl oor materials, i.e.
  • Page 36: Minimum Framing Dimensions

    6.1.1 MINIMUM FRAMING DIMENSIONS WARNING FOR TOP EXIT APPLICATIONS: DO NOT BUILD INTO THIS AREA. IT MUST BE LEFT CLEAR TO PROVIDE ADEQUATE CLEARANCE FOR THE VENT. IN THIS 14" WIDE AREA CENTRED ALONG THE FRONT OF THE APPLIANCE, NO COMBUSTIBLES ARE ALLOWED. TOP EXIT INSTALLATION STAND-OFF ASSEMBLY SHOWN...
  • Page 37: Bgd36 Framing

    BGD36 FRAMING WARNING RISK OF FIRE! IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN CONTACT WITH THE APPLIANCE BODY, IT IS RECOMMENDED THAT THE WALLS OF THE APPLIANCE ENCLOSURE BE “FINISHED” (IE: DRYWALL / SHEETROCK), AS YOU WOULD FINISH ANY OTHER OUTSIDE WALL OF A HOME.
  • Page 38: Minimum Framing Dimensions

    * BGD36 HORIZONTAL VENT SECTIONS: A minimum of 1" at the bottom and sides and 2" at the top of the vent pipe on all horizontal runs to combustibles is required. Use fi restop spacer W010-1774 (supplied). * BGD36 VERTICAL VENT SECTIONS: A minimum of 1" all around the vent pipe on all vertical runs to combustibles is required except for clearances in appliance enclosures.
  • Page 39: Minimum Enclosure Clearances

    MINIMUM ENCLOSURE CLEARANCES 6.3.1 GD36 COMBUSTIBLE NON-COMBUSTIBLE BRICK 0” IF 2” MINIMUM 2” NON-COMBUSTIBLE FINISHING IS USED SUCH AS BRICK AND STONE. 1” COMBUSTIBLE NON-COMBUSTIBLE 30” ” MINIMUM ” BRICK 0” IF NON-COMBUSTIBLE FINISHING IS USED 57” MINIMUM SUCH AS BRICK 2”...
  • Page 40: Bgd36

    6.3.2 BGD36 COMBUSTIBLE NON-COMBUSTIBLE BRICK 0” IF 2” MINIMUM 2” NON-COMBUSTIBLE COMBUSTIBLE NON-COMBUSTIBLE FINISHING IS USED SUCH AS BRICK BRICK 16” AND STONE. 6” MINIMUM 0” IF ” NON-COMBUSTIBLE 1” FINISHING IS USED SUCH AS BRICK 2” AND STONE. 39” ”...
  • Page 41: Alcove Clearances

    ALCOVE CLEARANCES RECESS OR ALCOVE AREA ENCLOSURE AREA APPLIANCE NOTE: Recesses or alcoves above the appliance can be made as deep as desired provided the minimum clearances to combustibles are maintained. Non-combustible material can be used, provided the minimum clearances to combustible materials are applied.
  • Page 42: Minimum Mantel Clearances

    MINIMUM MANTEL CLEARANCES WARNING RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE CLEARLY MAINTAINED.
  • Page 43: Finishing

    7.0 FINISHING WARNING RISK OF FIRE! NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT GO BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED. DO NOT STRIKE, SLAM OR SCRATCH GLASS.
  • Page 44: Louvre Installation

    LOUVRE INSTALLATION CLIPS SLOT CENTRE SLOT HINGE CLIP SLOT HOOD UPPER LOUVRES LOWER LOUVRES Attach the hood by Insert the louvre tabs Insert the hinge clips pressing the top fl ange into the slots located into the slots located at into the clips along the at the top left and right the bottom left and right...
  • Page 45: Log Placement

    LOG PLACEMENT WARNING FAILURE TO POSITION THE LOGS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY LOGS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. LOGS MUST BE PLACED IN THEIR EXACT LOCATION IN THE APPLIANCE. DO NOT MODIFY THE PROPER LOG POSITIONS, SINCE APPLIANCE MAY NOT FUNCTION PROPERLY AND DELAYED IGNITION MAY OCCUR.
  • Page 46: Charcoal Embers

    CHARCOAL EMBERS Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner. Fine dust found in the bottom of the bag should not be used. NOTE: Charcoal embers are not to be placed on the burner. 32.1 VERMICULITE (MODEL GD36 ONLY) Sprinkle vermiculite around the charcoal embers.
  • Page 47: Optional Rock Kit

    OPTIONAL ROCK KIT (RAK-ROCK ADAPTOR KIT IS NECESSARY WITH THIS KIT). WARNING REAL ROCKS MUST NOT BE USED IN THIS APPLIANCE. HEAT WILL CAUSE THEM TO EXPLODE. LOG SUPPORT BRACKET ROCK SUPPORT BRACKET Remove all logs and media. Move the two rock clusters into position, Remove the 2 screws and log support brackets lining up the studs located on the burner with already installed in the fi...
  • Page 48: Optional Blower Installation

    8.0 OPTIONAL BLOWER INSTALLATION WARNING RISK OF FIRE AND ELECTRICAL SHOCK. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE. USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
  • Page 49 Attach and secure the variable speed switch THERMAL SWITCH using the nut provided. Plug the harness cord into the receptacle.The wire harness provided in this kit is a universal harness. When installed, RECEPTACLE / JUNCTION BOX ensure that any excess wire is contained, preventing it from making contact with GROUND moving or hot objects.
  • Page 50: Operation

    9.0 OPERATION WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 51: Adjustment

    10.0 ADJUSTMENT 10.1 PILOT BURNER ADJUSTMENT Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise PILOT direction to reduce the gas fl ow. BURNER THERMOPILE Inlet pressure can be checked by turning screw (A) THERMOCOUPLE counter-clockwise until loosened and then placing pressure gauge tubing over the test point.
  • Page 52: Flame Characteristics

    10.3 FLAME CHARACTERISTICS It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustrations provided. If any fl ames 3/8” - 1/2” appear abnormal call a service person. FLAME MUST ENVELOP UPPER 3/8"...
  • Page 53: Door Glass Replacement

    11.1 DOOR GLASS REPLACEMENT WARNING DO NOT USE SUBSTITUTE MATERIALS. GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION.
  • Page 54: Replacements

    12.0 REPLACEMENTS WARNING FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. ** THIS IS A FAST ACTING THERMOCOUPLE. IT IS AN INTEGRAL SAFETY COMPONENT. REPLACE ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
  • Page 55 COMMON FLEXIBLE VENT KITS REF NO. PART NO. DESCRIPTION GD220 (5 FT) W010-0397 4" FLEXIBLE VENT PIPE - (5 FT) C/W SPACERS W410-0017 7" FLEXIBLE VENT PIPE - (5 FT) GD330 (10 FT) W410-0018 7" FLEXIBLE VENT PIPE -(10 FT) W010-0300 4"...
  • Page 56 COMMON ACCESSORIES REF NO. PART NO. DESCRIPTION VS47KT VENT PIPE SHIELD GZ550-1KT BLOWER KIT GD36 THERMOSTATIC SENSOR CONTROL KIT FOR USE WITH GD65 ONLY HOIK-3 HERITAGE ORNAMENTAL INSETS - BLACK HOIG-3 HERITAGE ORNAMENTAL INSETS - GOLD PLATED DK36-N DOOR KIT, NORTHERN -BLACK DK36-NPW DOOR KIT, NORTHERN - PEWTER DK36-R...
  • Page 57 W415-0773 / E / 03.13.12...
  • Page 58: Troubleshooting

    13.0 TROUBLESHOOTING WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 59 SYMPTOM PROBLEM TEST SOLUTION Pilot will not light. No spark at pilot burner. Check if pilot can be lit by a match. Check that the wire is connected to the push button igniter. Check if the push button igniter needs tightening. Replace the wire if the wire insulation is broken or frayed.
  • Page 60: Warranty

    14.0 WARRANTY NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2008 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station. The complete appliance is again thoroughly inspected by a qualifi...
  • Page 61: Service History

    15.0 SERVICE HISTORY 43.1 W415-0773 / E / 03.13.12...
  • Page 62 W415-0773 / E / 03.13.12...