Vent Information And Diagrams; Vent Table Key; Use Of Elbows; Measuring Standards - Heat & Glo SL-550TR-E Owner's Manual

Fireplaces
Hide thumbs Also See for SL-550TR-E:
Table of Contents

Advertisement

5 5

Vent Information and Diagrams

A. Vent Table Key
The abbreviations listed in this vent table key are used in
the vent diagrams.
Symbol
V
First section (closest to appliance) of vertical length
1
V
Second section of vertical length
2
H
First section (closest to appliance) of horizontal length
1
H
Second section of horizontal length
2
WARNING
Fire Hazard.
Explosion Risk.
Asphyxiation Risk.
Do NOT connect this gas appliance to a chimney
fl ue serving a separate solid-fuel or gas burning
appliance.
• Vent this appliance directly outside.
• Use separate vent system for this appliance.
May impair safe operation of this appliance or
other appliances connected to the fl ue.
B. Use of Elbows
CAUTION
ALL vent confi guration specifi cations MUST be followed.
• This product is tested and listed to these specifi cations.
• Appliance performance will suffer if specifi cations are
not followed.
Diagonal runs have both vertical and horizontal vent
aspects when calculating the effects. Use the rise for the
vertical aspect and the run for the horizontal aspect (see
Figure 5.1).
0
Two 45
elbows may be used in place of one 90
On 45
0
runs, one foot of diagonal is equal to 8.5 inches
horizontal run and 8.5 inches vertical run. A length of
straight pipe is allowed between two 45
Figure 5.1).
Description
0
elbow.
0
elbows (see
Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev. D • 6/07
Vertical
Figure 5.1
C. Measuring Standards
Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards.
1. Pipe measurements are shown using the effective length
of pipe (see Figure 5.2).
2. Measurements are made from the appliance outer wrap,
not from the standoffs.
3. Horizontal terminations are measured to the outside
mounting surface (fl ange of termination cap) (see
Figure 4.1).
4. Vertical terminations are measured to bottom of termina-
tion cap.
5. Horizontal pipe installed level with no rise.
Effective
Height/Length
Figure 5.2 DVP Pipe Effective Length
8-1/2 in.
Horizontal
Effective Length
Pipe
Inches
Millimeters
DVP4
4
102
DVP6
6
152
DVP12
12
305
DVP24
24
610
DVP36
36
914
DVP48
48
1219
DVP6A
3 to 6
76 to 152
DVP12A
3 to 12
76 to 305
DVP12MI 3 to 12
76 to 305
DVP24MI 3 to 24
76 to 610
13