lantern fuel, kerosene, charcoal lighter fluid, diesel fuel or any other flammable liquid to start the
fire. Do not use the manual startup method if the igniter is working. NEVER place firestarter near
the igniter. If you have continued problems with the Auto-Start Igniter, call Technical Support.
"E-Codes," or Error Codes, are codes that will appear in the Heat Range and Blower Speed
windows of the Control Board if your unit experiences problems. If you receive any of these codes,
first attempt to reset your unit by pressing the "ON" button (only once). If the unit continues to display
any E-Code(s), please contact Technical Support at (800) 245-6489 before further attempting to
restart your unit.
1. E-1 = Vacuum Loss
2. E-2 = Fail to Start
3. E-3 = Over Temperature Limit
NOTE: "E-0" indicates "No Error"
First Fire: Adjust the "Heat Range" to a "5" setting and allow the stove to burn in this manner
for at least three (3) hours. This will allow the unit to "cure out" as the paint and the
oils from the manufacturing process burn off. We recommend you open doors and
windows in your dwelling during this process.
Subsequent Cold Starts: In a cold start situation, the unit should be operated at a "5" setting
NOTE:
The start-up cycle for this unit with the Auto-Start Igniter is 13 minutes. Press the
"ON" button only once on start-up. Pressing the "ON" button a second time during
the start-up cycle will cause the start-up cycle to begin again.
IMPORTANT: If the unit fails to start properly, or does not properly complete the Shut-Down
procedure, open the closest outside door and a window to eliminate the home's
natural draft BEFORE opening the stove's door or hopper lid. This will allow any
smoke to exit through the external air hook-up instead of spilling into the home.
WARNING: NEVER SHUT DOWN THIS UNIT BY UNPLUGGING IT FROM THE POWER SOURCE.
Refer to the following instructions:
Press the "OFF" touch pad to put the stove in the "Shut-Down" mode.
"S D" in the Heat Range and Blower Speed windows while the unit is shutting down to verify this. At
this time the red light above the "OFF" pad will illuminate. When the "OFF" pad is touched the top
auger will instantly stop feeding pellets to the bottom auger tube, but the room air blower, exhaust
blower and bottom auger will continue to operate. When the internal temperature drops to 95 degrees
the room air blower will cease to operate, and when the internal temperature drops to 90 degrees the
bottom auger and exhaust blower will stop. The red light will then shut off and the entire stove will be
shut down. The hotter the unit is operating, the longer it will take for the stove to complete the Shut-
Down cycle.
Note: The unit will exit the Shut-Down cycle if you press any buttons during Shut-Down.
Note: If the room temperature stays above 70 degrees the stove will remain in the Shut Down mode
for 60 minutes, regardless of the temperature reading at the heat sensor. If the stove stays on
longer than 60 minutes the unit will automatically turn off.
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.

E-Codes

until the room air blower begins to operate.

SHUT-DOWN PROCEDURE

14
There will be an